{"api_version":"1","generated_at":"2026-07-04T17:22:33+00:00","cve":"CVE-2020-14479","urls":{"html":"https://cve.report/CVE-2020-14479","api":"https://cve.report/api/cve/CVE-2020-14479.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-14479","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-14479"},"summary":{"title":"CVE-2020-14479","description":"Sensitive information can be obtained through the handling of serialized data. The issue results from the lack of proper authentication required to query the server","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2022-04-01 23:15:00","updated_at":"2022-04-09 00:38:00"},"problem_types":["CWE-306"],"metrics":[],"references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-20-147-01","name":"https://www.cisa.gov/uscert/ics/advisories/icsa-20-147-01","refsource":"MISC","tags":[],"title":"Inductive Automation Ignition (Update B) | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-14479","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-14479","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"LEGACY","value":"Pedro Ribeiro, Radek Domanski, Chris Anastasio (muffin), and Steven Seeley (mr_me) working with Trend Micro’s Zero Day Initiative reported these vulnerabilities to CISA.","lang":""}],"nvd_cpes":[{"cve_year":"2020","cve_id":"14479","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"inductiveautomation","cpe5":"ignition","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"14479","vulnerable":"1","versionEndIncluding":"8.0.10","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"inductiveautomation","cpe5":"ignition","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","DATE_PUBLIC":"2020-07-14T17:00:00.000Z","ID":"CVE-2020-14479","STATE":"PUBLIC","TITLE":"ICSA-20-147-01 Inductive Automation Ignition (Update B)"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Ignition 7 Gateway","version":{"version_data":[{"version_affected":"<","version_name":"All","version_value":"7.9.14"}]}},{"product_name":"Ignition 8 Gateway","version":{"version_data":[{"version_affected":"<","version_name":"All","version_value":"8.0.10"}]}}]},"vendor_name":"Inductive Automation"}]}},"credit":[{"lang":"eng","value":"Pedro Ribeiro, Radek Domanski, Chris Anastasio (muffin), and Steven Seeley (mr_me) working with Trend Micro’s Zero Day Initiative reported these vulnerabilities to CISA."}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Sensitive information can be obtained through the handling of serialized data. The issue results from the lack of proper authentication required to query the server"}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":5.3,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-306 Missing Authentication for Critical Function"}]}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://www.cisa.gov/uscert/ics/advisories/icsa-20-147-01","name":"https://www.cisa.gov/uscert/ics/advisories/icsa-20-147-01"}]},"source":{"advisory":"ICSA-20-147-01","discovery":"EXTERNAL"},"work_around":[{"lang":"eng","value":"Please note CVE-2020-14479 does not have a fix in place. Induction Automation plans to correct this vulnerability in future product versions.\nIt is recommended to restrict interaction with the service to trusted machines. Only clients and servers with a legitimate procedural relationship should be permitted to communicate with the service. This can be done in various ways, most notably with firewall rules/allow listing.\nFor more information regarding software and patches, please refer to the specified version in Inductive Automation’s release notes."}]},"nvd":{"publishedDate":"2022-04-01 23:15:00","lastModifiedDate":"2022-04-09 00:38:00","problem_types":["CWE-306"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":5.3,"baseSeverity":"MEDIUM"},"exploitabilityScore":3.9,"impactScore":1.4},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":5},"severity":"MEDIUM","exploitabilityScore":10,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:inductiveautomation:ignition:*:*:*:*:*:*:*:*","versionStartIncluding":"8.0.1","versionEndIncluding":"8.0.10","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:inductiveautomation:ignition:*:*:*:*:*:*:*:*","versionStartIncluding":"7.0.0","versionEndExcluding":"7.9.14","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"14479","Ordinal":"175856","Title":"CVE-2020-14479","CVE":"CVE-2020-14479","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"14479","Ordinal":"1","NoteData":"** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided.","Type":"Description","Title":null}]}}}