{"api_version":"1","generated_at":"2026-07-23T12:12:51+00:00","cve":"CVE-2020-14504","urls":{"html":"https://cve.report/CVE-2020-14504","api":"https://cve.report/api/cve/CVE-2020-14504.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-14504","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-14504"},"summary":{"title":"CVE-2020-14504","description":"The web interface of the 1734-AENTR communication module mishandles authentication for HTTP POST requests. A remote, unauthenticated attacker can send a crafted request that may allow for modification of the configuration settings.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2022-02-24 19:15:00","updated_at":"2022-07-25 10:25:00"},"problem_types":["CWE-287"],"metrics":[],"references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-21-063-01","name":"https://www.cisa.gov/uscert/ics/advisories/icsa-21-063-01","refsource":"MISC","tags":[],"title":"Rockwell Automation 1734-AENTR Series B and Series C | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-14504","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-14504","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2020","cve_id":"14504","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"rockwellautomation","cpe5":"1734-aentr_point_i\\/o_dual_port_network_adaptor_series_b","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"14504","vulnerable":"1","versionEndIncluding":"4.005","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"rockwellautomation","cpe5":"1734-aentr_point_i\\/o_dual_port_network_adaptor_series_b_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"14504","vulnerable":"1","versionEndIncluding":"5.017","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"rockwellautomation","cpe5":"1734-aentr_point_i\\/o_dual_port_network_adaptor_series_b_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"14504","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"rockwellautomation","cpe5":"1734-aentr_point_i\\/o_dual_port_network_adaptor_series_c","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"14504","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"rockwellautomation","cpe5":"1734-aentr_point_i\\/o_dual_port_network_adaptor_series_c_firmware","cpe6":"6.011","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"14504","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"rockwellautomation","cpe5":"1734-aentr_point_i\\/o_dual_port_network_adaptor_series_c_firmware","cpe6":"6.012","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","DATE_PUBLIC":"2021-03-04T17:00:00.000Z","ID":"CVE-2020-14504","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"1734-AENTR","version":{"version_data":[{"version_affected":"=","version_name":"Series B","version_value":"4.001 to 4.005, and 5.011 to 5.017"},{"version_affected":"=","version_name":"Series C","version_value":"6.011 and 6.012"}]}}]},"vendor_name":"Rockwell Automation"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"The web interface of the 1734-AENTR communication module mishandles authentication for HTTP POST requests. A remote, unauthenticated attacker can send a crafted request that may allow for modification of the configuration settings."}]},"generator":{"engine":"Vulnogram 0.0.9"},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-284 Improper Access Control"}]}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://www.cisa.gov/uscert/ics/advisories/icsa-21-063-01","name":"https://www.cisa.gov/uscert/ics/advisories/icsa-21-063-01"}]},"source":{"discovery":"EXTERNAL"}},"nvd":{"publishedDate":"2022-02-24 19:15:00","lastModifiedDate":"2022-07-25 10:25:00","problem_types":["CWE-287"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"LOW","availabilityImpact":"NONE","baseScore":5.3,"baseSeverity":"MEDIUM"},"exploitabilityScore":3.9,"impactScore":1.4},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:P/A:N","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE","baseScore":5},"severity":"MEDIUM","exploitabilityScore":10,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:rockwellautomation:1734-aentr_point_i\\/o_dual_port_network_adaptor_series_b_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"4.001","versionEndIncluding":"4.005","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:rockwellautomation:1734-aentr_point_i\\/o_dual_port_network_adaptor_series_b_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"5.011","versionEndIncluding":"5.017","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:rockwellautomation:1734-aentr_point_i\\/o_dual_port_network_adaptor_series_b:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:rockwellautomation:1734-aentr_point_i\\/o_dual_port_network_adaptor_series_c_firmware:6.011:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:rockwellautomation:1734-aentr_point_i\\/o_dual_port_network_adaptor_series_c_firmware:6.012:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:rockwellautomation:1734-aentr_point_i\\/o_dual_port_network_adaptor_series_c:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"14504","Ordinal":"175881","Title":"CVE-2020-14504","CVE":"CVE-2020-14504","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"14504","Ordinal":"1","NoteData":"** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided.","Type":"Description","Title":null}]}}}