{"api_version":"1","generated_at":"2026-07-23T11:53:43+00:00","cve":"CVE-2020-14514","urls":{"html":"https://cve.report/CVE-2020-14514","api":"https://cve.report/api/cve/CVE-2020-14514.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-14514","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-14514"},"summary":{"title":"CVE-2020-14514","description":"All trailer Power Line Communications are affected. PLC bus traffic can be sniffed reliably via an active antenna up to 6 feet away. Further distances are also possible, subject to environmental conditions and receiver improvements.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2020-09-01 14:15:00","updated_at":"2020-09-11 14:08:00"},"problem_types":["CWE-201"],"metrics":[],"references":[{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-20-219-01","name":"https://us-cert.cisa.gov/ics/advisories/icsa-20-219-01","refsource":"MISC","tags":["Third Party Advisory","US Government Resource"],"title":"Trailer Power Line Communications | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-14514","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-14514","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2020","cve_id":"14514","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"nmfc","cpe5":"power_line_communications","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"14514","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"nmfc","cpe5":"power_line_communications","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2020-14514","STATE":"PUBLIC","TITLE":"Trailer Power Line Communications vulnerability"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Multiple Vendors All trailer power line communications are affected.","product":{"product_data":[{"product_name":"Trailer Power Line Communications","version":{"version_data":[{"version_value":"All trailer power line communications are affected."}]}}]}}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"All trailer Power Line Communications are affected. PLC bus traffic can be sniffed reliably via an active antenna up to 6 feet away. Further distances are also possible, subject to environmental conditions and receiver improvements."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"NONE","baseScore":4.3,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"EXPOSURE OF SENSITIVE INFORMATION THROUGH SENT DATA CWE-201"}]}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://us-cert.cisa.gov/ics/advisories/icsa-20-219-01","name":"https://us-cert.cisa.gov/ics/advisories/icsa-20-219-01"}]},"source":{"discovery":"UNKNOWN"}},"nvd":{"publishedDate":"2020-09-01 14:15:00","lastModifiedDate":"2020-09-11 14:08:00","problem_types":["CWE-201"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":4.3,"baseSeverity":"MEDIUM"},"exploitabilityScore":2.8,"impactScore":1.4},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:A/AC:L/Au:N/C:P/I:N/A:N","accessVector":"ADJACENT_NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":3.3},"severity":"LOW","exploitabilityScore":6.5,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:nmfc:power_line_communications:*:*:*:*:*:*:*:*","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"14514","Ordinal":"175891","Title":"CVE-2020-14514","CVE":"CVE-2020-14514","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"14514","Ordinal":"1","NoteData":"All trailer Power Line Communications are affected. PLC bus traffic can be sniffed reliably via an active antenna up to 6 feet away. Further distances are also possible, subject to environmental conditions and receiver improvements.","Type":"Description","Title":null},{"CveYear":"2020","CveId":"14514","Ordinal":"2","NoteData":"2020-09-01","Type":"Other","Title":"Published"},{"CveYear":"2020","CveId":"14514","Ordinal":"3","NoteData":"2020-09-01","Type":"Other","Title":"Modified"}]}}}