{"api_version":"1","generated_at":"2026-04-22T22:03:32+00:00","cve":"CVE-2020-14525","urls":{"html":"https://cve.report/CVE-2020-14525","api":"https://cve.report/api/cve/CVE-2020-14525.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-14525","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-14525"},"summary":{"title":"CVE-2020-14525","description":"Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2020-09-18 18:15:00","updated_at":"2020-09-25 18:51:00"},"problem_types":["NVD-CWE-Other"],"metrics":[],"references":[{"url":"https://us-cert.cisa.gov/ics/advisories/icsma-20-261-01","name":"https://us-cert.cisa.gov/ics/advisories/icsma-20-261-01","refsource":"MISC","tags":["Third Party Advisory","US Government Resource"],"title":"Philips Clinical Collaboration Platform | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-14525","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-14525","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2020","cve_id":"14525","vulnerable":"1","versionEndIncluding":"12.2.1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"philips","cpe5":"clinical_collaboration_platform","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2020-14525","ASSIGNER":"ics-cert@hq.dhs.gov","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"Philips Clinical Collaboration Platform","version":{"version_data":[{"version_value":"Versions 12.2.1 and prior"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"IMPROPER NEUTRALIZATION OF SCRIPT IN ATTRIBUTES IN A WEB PAGE CWE-83"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://us-cert.cisa.gov/ics/advisories/icsma-20-261-01","url":"https://us-cert.cisa.gov/ics/advisories/icsma-20-261-01"}]},"description":{"description_data":[{"lang":"eng","value":"Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users."}]}},"nvd":{"publishedDate":"2020-09-18 18:15:00","lastModifiedDate":"2020-09-25 18:51:00","problem_types":["NVD-CWE-Other"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":3.5,"baseSeverity":"LOW"},"exploitabilityScore":2.1,"impactScore":1.4},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:A/AC:L/Au:S/C:P/I:N/A:N","accessVector":"ADJACENT_NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":2.7},"severity":"LOW","exploitabilityScore":5.1,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:philips:clinical_collaboration_platform:*:*:*:*:*:*:*:*","versionEndIncluding":"12.2.1","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"14525","Ordinal":"175902","Title":"CVE-2020-14525","CVE":"CVE-2020-14525","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"14525","Ordinal":"1","NoteData":"Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users.","Type":"Description","Title":null},{"CveYear":"2020","CveId":"14525","Ordinal":"2","NoteData":"2020-09-18","Type":"Other","Title":"Published"},{"CveYear":"2020","CveId":"14525","Ordinal":"3","NoteData":"2020-09-18","Type":"Other","Title":"Modified"}]}}}