{"api_version":"1","generated_at":"2026-04-22T22:03:34+00:00","cve":"CVE-2020-16247","urls":{"html":"https://cve.report/CVE-2020-16247","api":"https://cve.report/api/cve/CVE-2020-16247.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-16247","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-16247"},"summary":{"title":"CVE-2020-16247","description":"Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2020-09-18 18:15:00","updated_at":"2022-04-25 17:42:00"},"problem_types":["CWE-668"],"metrics":[],"references":[{"url":"https://us-cert.cisa.gov/ics/advisories/icsma-20-261-01","name":"https://us-cert.cisa.gov/ics/advisories/icsma-20-261-01","refsource":"MISC","tags":["Third Party Advisory","US Government Resource"],"title":"Philips Clinical Collaboration Platform | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-16247","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-16247","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2020","cve_id":"16247","vulnerable":"1","versionEndIncluding":"12.2.1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"philips","cpe5":"clinical_collaboration_platform","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2020-16247","ASSIGNER":"ics-cert@hq.dhs.gov","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"Philips Clinical Collaboration Platform","version":{"version_data":[{"version_value":"Versions 12.2.1 and prior"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CONFIGURATION CWE-16"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://us-cert.cisa.gov/ics/advisories/icsma-20-261-01","url":"https://us-cert.cisa.gov/ics/advisories/icsma-20-261-01"}]},"description":{"description_data":[{"lang":"eng","value":"Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource."}]}},"nvd":{"publishedDate":"2020-09-18 18:15:00","lastModifiedDate":"2022-04-25 17:42:00","problem_types":["CWE-668"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"NONE","baseScore":7.1,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.2},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:P/I:P/A:N","accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"NONE","baseScore":3.6},"severity":"LOW","exploitabilityScore":3.9,"impactScore":4.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:philips:clinical_collaboration_platform:*:*:*:*:*:*:*:*","versionEndIncluding":"12.2.1","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"16247","Ordinal":"177655","Title":"CVE-2020-16247","CVE":"CVE-2020-16247","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"16247","Ordinal":"1","NoteData":"Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource.","Type":"Description","Title":null},{"CveYear":"2020","CveId":"16247","Ordinal":"2","NoteData":"2020-09-18","Type":"Other","Title":"Published"},{"CveYear":"2020","CveId":"16247","Ordinal":"3","NoteData":"2020-09-18","Type":"Other","Title":"Modified"}]}}}