{"api_version":"1","generated_at":"2026-04-23T01:32:37+00:00","cve":"CVE-2020-17437","urls":{"html":"https://cve.report/CVE-2020-17437","api":"https://cve.report/api/cve/CVE-2020-17437.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-17437","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-17437"},"summary":{"title":"CVE-2020-17437","description":"An issue was discovered in uIP 1.0, as used in Contiki 3.0 and other products. When the Urgent flag is set in a TCP packet, and the stack is configured to ignore the urgent data, the stack attempts to use the value of the Urgent pointer bytes to separate the Urgent data from the normal data, by calculating the offset at which the normal data should be present in the global buffer. However, the length of this offset is not checked; therefore, for large values of the Urgent pointer bytes, the data pointer can point to memory that is way beyond the data buffer in uip_process in uip.c.","state":"PUBLIC","assigner":"cve@mitre.org","published_at":"2020-12-11 23:15:00","updated_at":"2022-08-08 14:57:00"},"problem_types":["CWE-787"],"metrics":[],"references":[{"url":"https://www.kb.cert.org/vuls/id/815128","name":"https://www.kb.cert.org/vuls/id/815128","refsource":"MISC","tags":["Third Party Advisory","US Government Resource"],"title":"VU#815128 - Embedded TCP/IP stacks have memory corruption vulnerabilities","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-541018.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-541018.pdf","refsource":"CONFIRM","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"0"},{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-20-343-01","name":"https://us-cert.cisa.gov/ics/advisories/icsa-20-343-01","refsource":"MISC","tags":["Third Party Advisory","US Government Resource"],"title":"Multiple Embedded TCP/IP Stacks | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-17437","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-17437","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2020","cve_id":"17437","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"contiki-os","cpe5":"contiki","cpe6":"3.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"17437","vulnerable":"-1","versionEndIncluding":"3.0","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"contiki-os","cpe5":"contiki","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"17437","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"contiki-os","cpe5":"contiki","cpe6":"3.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"17437","vulnerable":"1","versionEndIncluding":"2.1.12","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"open-iscsi_project","cpe5":"open-iscsi","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"17437","vulnerable":"1","versionEndIncluding":"2.1.7","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"open-iscsi_project","cpe5":"open-iscsi","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"17437","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"sentron_3va_com100","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"17437","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"sentron_3va_com100_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"17437","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"sentron_3va_com800","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"17437","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"sentron_3va_com800_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"17437","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"sentron_3va_dsp800","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"17437","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"sentron_3va_dsp800_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"17437","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"sentron_pac2200","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"17437","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"sentron_pac2200_clp","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"17437","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"sentron_pac2200_clp_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"17437","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"sentron_pac2200_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"17437","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"sentron_pac3200","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"17437","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"sentron_pac3200t","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"17437","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"sentron_pac3200t_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"17437","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"sentron_pac3200_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"17437","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"sentron_pac3220","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"17437","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"sentron_pac3220_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"17437","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"sentron_pac4200","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"17437","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"sentron_pac4200_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"17437","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"uip_project","cpe5":"uip","cpe6":"1.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"17437","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"uip_project","cpe5":"uip","cpe6":"1.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"17437","vulnerable":"1","versionEndIncluding":"1.0","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"uip_project","cpe5":"uip","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2020-17437","qid":"174892","title":"SUSE Enterprise Linux Security Update for open-iscsi (SUSE-SU-2021:1164-1)"},{"cve":"CVE-2020-17437","qid":"199622","title":"Ubuntu Security Notification for Open-iSCSI Vulnerabilities (USN-6259-1)"},{"cve":"CVE-2020-17437","qid":"590706","title":"Siemens TCP/IP Stack AMNESIA:33 in SENTRON PAC/3VA Devices (Update C) Multiple Vulnerabilities (ICSA-21-068-06)"},{"cve":"CVE-2020-17437","qid":"670184","title":"EulerOS Security Update for iscsi-initiator-utils (EulerOS-SA-2021-1683)"},{"cve":"CVE-2020-17437","qid":"673041","title":"EulerOS Security Update for open-iscsi (EulerOS-SA-2023-1980)"},{"cve":"CVE-2020-17437","qid":"673050","title":"EulerOS Security Update for open-iscsi (EulerOS-SA-2023-1958)"}]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2020-17437","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An issue was discovered in uIP 1.0, as used in Contiki 3.0 and other products. When the Urgent flag is set in a TCP packet, and the stack is configured to ignore the urgent data, the stack attempts to use the value of the Urgent pointer bytes to separate the Urgent data from the normal data, by calculating the offset at which the normal data should be present in the global buffer. However, the length of this offset is not checked; therefore, for large values of the Urgent pointer bytes, the data pointer can point to memory that is way beyond the data buffer in uip_process in uip.c."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://www.kb.cert.org/vuls/id/815128","url":"https://www.kb.cert.org/vuls/id/815128"},{"refsource":"MISC","name":"https://us-cert.cisa.gov/ics/advisories/icsa-20-343-01","url":"https://us-cert.cisa.gov/ics/advisories/icsa-20-343-01"},{"refsource":"CONFIRM","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-541018.pdf","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-541018.pdf"}]}},"nvd":{"publishedDate":"2020-12-11 23:15:00","lastModifiedDate":"2022-08-08 14:57:00","problem_types":["CWE-787"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"HIGH","baseScore":8.2,"baseSeverity":"HIGH"},"exploitabilityScore":3.9,"impactScore":4.2},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:P","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"PARTIAL","baseScore":6.4},"severity":"MEDIUM","exploitabilityScore":10,"impactScore":4.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:uip_project:uip:*:*:*:*:*:*:*:*","versionEndIncluding":"1.0","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:o:contiki-os:contiki:*:*:*:*:*:*:*:*","versionEndIncluding":"3.0","cpe_name":[]}]}],"cpe_match":[]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:open-iscsi_project:open-iscsi:*:*:*:*:*:*:*:*","versionEndIncluding":"2.1.7","cpe_name":[]}]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:sentron_3va_com100_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.4.1","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:sentron_3va_com100:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:sentron_3va_com800_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.4.1","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:sentron_3va_com800:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:sentron_3va_dsp800_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.0","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:sentron_3va_dsp800:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:sentron_pac2200_clp_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:sentron_pac2200_clp:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:sentron_pac2200_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"3.2.2","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:sentron_pac2200:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:sentron_pac3200_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.4.7","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:sentron_pac3200:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:sentron_pac3200t_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"3.2.2","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:sentron_pac3200t:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:sentron_pac3220_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"3.2.0","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:sentron_pac3220:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:sentron_pac4200_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.3.0","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:sentron_pac4200:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"17437","Ordinal":"178846","Title":"CVE-2020-17437","CVE":"CVE-2020-17437","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"17437","Ordinal":"1","NoteData":"An issue was discovered in uIP 1.0, as used in Contiki 3.0 and other products. When the Urgent flag is set in a TCP packet, and the stack is configured to ignore the urgent data, the stack attempts to use the value of the Urgent pointer bytes to separate the Urgent data from the normal data, by calculating the offset at which the normal data should be present in the global buffer. However, the length of this offset is not checked; therefore, for large values of the Urgent pointer bytes, the data pointer can point to memory that is way beyond the data buffer in uip_process in uip.c.","Type":"Description","Title":null},{"CveYear":"2020","CveId":"17437","Ordinal":"2","NoteData":"2020-12-11","Type":"Other","Title":"Published"},{"CveYear":"2020","CveId":"17437","Ordinal":"3","NoteData":"2021-03-09","Type":"Other","Title":"Modified"}]}}}