{"api_version":"1","generated_at":"2026-04-25T16:05:08+00:00","cve":"CVE-2020-24987","urls":{"html":"https://cve.report/CVE-2020-24987","api":"https://cve.report/api/cve/CVE-2020-24987.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-24987","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-24987"},"summary":{"title":"CVE-2020-24987","description":"Tenda AC18 Router through V15.03.05.05_EN and through V15.03.05.19(6318) CN devices could cause a remote code execution due to incorrect authentication handling of vulnerable logincheck() function in /usr/lib/lua/ngx_authserver/ngx_wdas.lua file if the administrator UI Interface is set to \"radius\".","state":"PUBLIC","assigner":"cve@mitre.org","published_at":"2020-09-04 20:15:00","updated_at":"2022-11-07 13:39:00"},"problem_types":["CWE-287"],"metrics":[],"references":[{"url":"https://drive.google.com/file/d/1iqpr0EofOBC6kCq2USTOBPRlJu_naFjQ/view?usp=sharing","name":"https://drive.google.com/file/d/1iqpr0EofOBC6kCq2USTOBPRlJu_naFjQ/view?usp=sharing","refsource":"MISC","tags":["Broken Link"],"title":"Tenda AC18.pdf - Google Drive","mime":"text/html","httpstatus":"429","archivestatus":"200"},{"url":"https://www.tendacn.com/en/product/AC18.html","name":"https://www.tendacn.com/en/product/AC18.html","refsource":"MISC","tags":["Product","Vendor Advisory"],"title":"Tenda AC18 AC 1900 Smart Dual-Band Gigabit WiFi Router-Tenda-All For Better NetWorking","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://cwe.mitre.org/data/definitions/287.html","name":"https://cwe.mitre.org/data/definitions/287.html","refsource":"MISC","tags":[],"title":"CWE -\r\n\n\t\tCWE-287: Improper Authentication (4.3)","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-24987","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-24987","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2020","cve_id":"24987","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"tendacn","cpe5":"ac18","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"24987","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"tendacn","cpe5":"ac18","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"24987","vulnerable":"1","versionEndIncluding":"v15.03.05.05_en","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tendacn","cpe5":"ac18_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"24987","vulnerable":"1","versionEndIncluding":"v15.03.05.19(6318)_cn","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tendacn","cpe5":"ac18_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"24987","vulnerable":"1","versionEndIncluding":"v15.03.05.19\\(6318\\)_cn","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"tendacn","cpe5":"ac18_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2020-24987","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Tenda AC18 Router through V15.03.05.05_EN and through V15.03.05.19(6318) CN devices could cause a remote code execution due to incorrect authentication handling of vulnerable logincheck() function in /usr/lib/lua/ngx_authserver/ngx_wdas.lua file if the administrator UI Interface is set to \"radius\"."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"url":"https://www.tendacn.com/en/product/AC18.html","refsource":"MISC","name":"https://www.tendacn.com/en/product/AC18.html"},{"url":"https://drive.google.com/file/d/1iqpr0EofOBC6kCq2USTOBPRlJu_naFjQ/view?usp=sharing","refsource":"MISC","name":"https://drive.google.com/file/d/1iqpr0EofOBC6kCq2USTOBPRlJu_naFjQ/view?usp=sharing"},{"refsource":"MISC","name":"https://cwe.mitre.org/data/definitions/287.html","url":"https://cwe.mitre.org/data/definitions/287.html"}]}},"nvd":{"publishedDate":"2020-09-04 20:15:00","lastModifiedDate":"2022-11-07 13:39:00","problem_types":["CWE-287"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL"},"exploitabilityScore":3.9,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":6.8},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:tendacn:ac18_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"v15.03.05.05_en","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:tendacn:ac18:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:tendacn:ac18_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"v15.03.05.19\\(6318\\)_cn","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:tendacn:ac18:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"24987","Ordinal":"186397","Title":"CVE-2020-24987","CVE":"CVE-2020-24987","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"24987","Ordinal":"1","NoteData":"Tenda AC18 Router through V15.03.05.05_EN and through V15.03.05.19(6318) CN devices could cause a remote code execution due to incorrect authentication handling of vulnerable logincheck() function in /usr/lib/lua/ngx_authserver/ngx_wdas.lua file if the administrator UI Interface is set to \"radius\".","Type":"Description","Title":null},{"CveYear":"2020","CveId":"24987","Ordinal":"2","NoteData":"2020-09-04","Type":"Other","Title":"Published"},{"CveYear":"2020","CveId":"24987","Ordinal":"3","NoteData":"2020-09-04","Type":"Other","Title":"Modified"}]}}}