{"api_version":"1","generated_at":"2026-06-04T13:01:14+00:00","cve":"CVE-2020-25082","urls":{"html":"https://cve.report/CVE-2020-25082","api":"https://cve.report/api/cve/CVE-2020-25082.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-25082","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-25082"},"summary":{"title":"CVE-2020-25082","description":"An attacker with physical access to Nuvoton Trusted Platform Module (NPCT75x 7.2.x before 7.2.2.0) could extract an Elliptic Curve Cryptography (ECC) private key via a side-channel attack against ECDSA, because of an Observable Timing Discrepancy.","state":"PUBLIC","assigner":"cve@mitre.org","published_at":"2021-08-10 17:15:00","updated_at":"2021-08-17 17:48:00"},"problem_types":["CWE-203"],"metrics":[],"references":[{"url":"https://www.nuvoton.com/support/product-related-information/security-advisories/sa-002/","name":"https://www.nuvoton.com/support/product-related-information/security-advisories/sa-002/","refsource":"MISC","tags":[],"title":"SA-002: Potential Extraction of an Elliptic Curve Cryptography (ECC) private key via a side-channel attack against ECDSA - Nuvoton","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-25082","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-25082","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2020","cve_id":"25082","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"nuvoton","cpe5":"npct75x","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"25082","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"nuvoton","cpe5":"npct75x_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2020-25082","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An attacker with physical access to Nuvoton Trusted Platform Module (NPCT75x 7.2.x before 7.2.2.0) could extract an Elliptic Curve Cryptography (ECC) private key via a side-channel attack against ECDSA, because of an Observable Timing Discrepancy."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://www.nuvoton.com/support/product-related-information/security-advisories/sa-002/","url":"https://www.nuvoton.com/support/product-related-information/security-advisories/sa-002/"}]},"impact":{"cvss":{"attackComplexity":"HIGH","attackVector":"PHYSICAL","availabilityImpact":"NONE","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AC:H/AV:P/A:N/C:H/I:N/PR:H/S:U/UI:N","version":"3.1"}}},"nvd":{"publishedDate":"2021-08-10 17:15:00","lastModifiedDate":"2021-08-17 17:48:00","problem_types":["CWE-203"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N","attackVector":"PHYSICAL","attackComplexity":"HIGH","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":3.8,"baseSeverity":"LOW"},"exploitabilityScore":0.2,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:M/Au:N/C:P/I:N/A:N","accessVector":"LOCAL","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":1.9},"severity":"LOW","exploitabilityScore":3.4,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:nuvoton:npct75x_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"7.2.0","versionEndExcluding":"7.2.2.0","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:nuvoton:npct75x:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"25082","Ordinal":"186492","Title":"CVE-2020-25082","CVE":"CVE-2020-25082","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"25082","Ordinal":"1","NoteData":"An attacker with physical access to Nuvoton Trusted Platform Module (NPCT75x 7.2.x before 7.2.2.0) could extract an Elliptic Curve Cryptography (ECC) private key via a side-channel attack against ECDSA, because of an Observable Timing Discrepancy.","Type":"Description","Title":null},{"CveYear":"2020","CveId":"25082","Ordinal":"2","NoteData":"2021-08-10","Type":"Other","Title":"Published"},{"CveYear":"2020","CveId":"25082","Ordinal":"3","NoteData":"2021-08-10","Type":"Other","Title":"Modified"}]}}}