{"api_version":"1","generated_at":"2026-04-22T23:08:43+00:00","cve":"CVE-2020-25238","urls":{"html":"https://cve.report/CVE-2020-25238","api":"https://cve.report/api/cve/CVE-2020-25238.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-25238","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-25238"},"summary":{"title":"CVE-2020-25238","description":"A vulnerability has been identified in PCS neo (Administration Console) (All versions < V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system.","state":"PUBLIC","assigner":"productcert@siemens.com","published_at":"2021-02-09 17:15:00","updated_at":"2022-10-21 18:21:00"},"problem_types":["CWE-427"],"metrics":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf","refsource":"MISC","tags":["Vendor Advisory"],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"200"},{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05","name":"https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05","refsource":"MISC","tags":["Third Party Advisory","VDB Entry"],"title":"Siemens TIA Administrator | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.kb.cert.org/vuls/id/466044","name":"VU#466044","refsource":"CERT-VN","tags":["Third Party Advisory"],"title":"VU#466044 - Siemens Totally Integrated Automation Portal vulnerable to privilege escalation due to Node.js paths","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-25238","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-25238","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2020","cve_id":"25238","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_process_control_system_neo","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"25238","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_process_control_system_neo","cpe6":"3.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"25238","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"simatic_process_control_system_neo","cpe6":"3.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"25238","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"totally_integrated_automation_portal","cpe6":"15","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"25238","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"totally_integrated_automation_portal","cpe6":"15.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"25238","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"totally_integrated_automation_portal","cpe6":"16","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"25238","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"totally_integrated_automation_portal","cpe6":"15","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"25238","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"totally_integrated_automation_portal","cpe6":"15.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"25238","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"totally_integrated_automation_portal","cpe6":"16","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2020-25238","STATE":"PUBLIC"},"data_format":"MITRE","data_version":"4.0","data_type":"CVE","affects":{"vendor":{"vendor_data":[{"vendor_name":"Siemens","product":{"product_data":[{"product_name":"PCS neo (Administration Console)","version":{"version_data":[{"version_value":"All versions < V3.1"}]}},{"product_name":"TIA Portal","version":{"version_data":[{"version_value":"V15, V15.1 and V16"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-284: Improper Access Control"}]}]},"description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in PCS neo (Administration Console) (All versions < V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system."}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf"},{"refsource":"CERT-VN","name":"VU#466044","url":"https://www.kb.cert.org/vuls/id/466044"},{"refsource":"MISC","name":"https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05","url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05"}]}},"nvd":{"publishedDate":"2021-02-09 17:15:00","lastModifiedDate":"2022-10-21 18:21:00","problem_types":["CWE-427"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:C/I:C/A:C","accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE","baseScore":7.2},"severity":"HIGH","exploitabilityScore":3.9,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:totally_integrated_automation_portal:16:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:totally_integrated_automation_portal:15.1:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:totally_integrated_automation_portal:15:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:simatic_process_control_system_neo:*:*:*:*:*:*:*:*","versionEndExcluding":"3.1","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"25238","Ordinal":"186649","Title":"CVE-2020-25238","CVE":"CVE-2020-25238","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"25238","Ordinal":"1","NoteData":"A vulnerability has been identified in PCS neo (Administration Console) (All versions < V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system.","Type":"Description","Title":null},{"CveYear":"2020","CveId":"25238","Ordinal":"2","NoteData":"2021-02-09","Type":"Other","Title":"Published"},{"CveYear":"2020","CveId":"25238","Ordinal":"3","NoteData":"2021-09-14","Type":"Other","Title":"Modified"}]}}}