{"api_version":"1","generated_at":"2026-04-22T23:08:37+00:00","cve":"CVE-2020-26141","urls":{"html":"https://cve.report/CVE-2020-26141","api":"https://cve.report/api/cve/CVE-2020-26141.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-26141","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-26141"},"summary":{"title":"CVE-2020-26141","description":"An issue was discovered in the ALFA Windows 10 driver 6.1316.1209 for AWUS036H. The Wi-Fi implementation does not verify the Message Integrity Check (authenticity) of fragmented TKIP frames. An adversary can abuse this to inject and possibly decrypt packets in WPA or WPA2 networks that support the TKIP data-confidentiality protocol.","state":"PUBLISHED","assigner":"mitre","published_at":"2021-05-11 20:15:08","updated_at":"2026-04-14 09:16:23"},"problem_types":["CWE-354","n/a"],"metrics":[{"version":"3.1","source":"nvd@nist.gov","type":"Primary","score":"6.5","severity":"MEDIUM","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"HIGH","availabilityImpact":"NONE"}},{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"3.3","severity":"","vector":"AV:A/AC:L/Au:N/C:N/I:P/A:N","data":{"version":"2.0","vectorString":"AV:A/AC:L/Au:N/C:N/I:P/A:N","baseScore":3.3,"accessVector":"ADJACENT_NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"}}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md","name":"https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"],"title":"fragattacks/SUMMARY.md at master · vanhoefm/fragattacks · GitHub","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-019200.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-019200.html","refsource":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.fragattacks.com","name":"https://www.fragattacks.com","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"],"title":"FragAttacks: Security flaws in all Wi-Fi devices","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-913875.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-913875.html","refsource":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63","name":"https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"],"title":"Security Advisory 0063 - Arista","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWu","name":"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWu","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"],"title":"Multiple Vulnerabilities in Frame Aggregation and Fragmentation Implementations of 802.11 Specification Affecting Cisco Products: May 2021","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.openwall.com/lists/oss-security/2021/05/11/12","name":"http://www.openwall.com/lists/oss-security/2021/05/11/12","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Mailing List","Third Party Advisory"],"title":"oss-security - various 802.11 security issues - fragattacks.com","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-26141","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-26141","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"n/a","version":"affected n/a","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W721-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W721-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W721-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W721-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W722-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W722-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W722-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W722-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W722-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W722-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45 (USA)","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45 (USA)","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W738-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W738-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W738-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W738-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W761-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W761-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W761-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W761-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45 (USA)","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45 (USA)","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12 EEC (USA)","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12 EEC (USA)","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 SFP","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 SFP","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 SFP","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 SFP","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2IA RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2IA RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2IA RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2IA RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 RJ45","version":"affected V6.6.0 custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"alfa","cpe5":"awus036h","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"alfa","cpe5":"awus036h_firmware","cpe6":"6.1316.1209","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"windows_10","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"ip_conference_phone_8832","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"ip_conference_phone_8832_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"ip_phone_6861","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"ip_phone_6861_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"ip_phone_8861","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"ip_phone_8861","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"3pcc","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"ip_phone_8861_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"ip_phone_8861_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"3pcc","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"ip_phone_8865","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"ip_phone_8865_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_gr10","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_gr10_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_gr60","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_gr60_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr12","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr12_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr18","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr18_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr20","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr20_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr26","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr26_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr30h","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr30h_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr32","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr32_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr33","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr33_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr34","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr34_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr36","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr36_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr42","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr42e","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr42e_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr42_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr44","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr44_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr45","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr45_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr46","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr46e","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr46e_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr46_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr52","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr52_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr53","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr53e","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr53e_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr53_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr55","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr55_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr56","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr56_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr62","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr62_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr66","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr66_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr70","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr70_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr72","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr72_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr74","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr74_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr76","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr76_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr84","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr84_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mr86","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mr86_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mx64w","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mx64w_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mx65w","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mx65w_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mx67cw","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mx67cw_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mx67w","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mx67w_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mx68cw","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mx68cw_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_mx68w","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_mx68w_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_z3","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"meraki_z3c","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_z3c_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"meraki_z3_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"webex_board_series","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"webex_board_series_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"webex_desk_series","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"webex_desk_series_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"webex_room_series","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"webex_room_series_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"webex_wireless_phone_840","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"webex_wireless_phone_840_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"webex_wireless_phone_860","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"webex_wireless_phone_860_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"cisco","cpe5":"wireless_ip_phone_8821","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"cisco","cpe5":"wireless_ip_phone_8821_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5721-1fc00-0aa0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5721-1fc00-0aa0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5721-1fc00-0ab0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5721-1fc00-0ab0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5722-1fc00-0aa0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5722-1fc00-0aa0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5722-1fc00-0ab0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5722-1fc00-0ab0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5722-1fc00-0ac0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5722-1fc00-0ac0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5734-1fx00-0aa0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5734-1fx00-0aa0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5734-1fx00-0aa6","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5734-1fx00-0aa6_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5734-1fx00-0ab0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5734-1fx00-0ab0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5734-1fx00-0ab6","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5734-1fx00-0ab6_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5738-1gy00-0aa0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5738-1gy00-0aa0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5738-1gy00-0ab0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5738-1gy00-0ab0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5748-1fc00-0aa0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5748-1fc00-0aa0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5748-1fc00-0ab0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5748-1fc00-0ab0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5748-1gd00-0aa0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5748-1gd00-0aa0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5748-1gd00-0ab0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5748-1gd00-0ab0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5761-1fc00-0aa0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5761-1fc00-0aa0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5761-1fc00-0ab0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5761-1fc00-0ab0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5774-1fx00-0aa0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5774-1fx00-0aa0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5774-1fx00-0aa6","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5774-1fx00-0aa6_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5774-1fx00-0ab0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5774-1fx00-0ab0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5774-1fx00-0ab6","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5774-1fx00-0ab6_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5774-1fy00-0ta0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12_ecc","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5774-1fy00-0ta0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12_ecc","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5774-1fy00-0tb0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12_ecc","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5774-1fy00-0tb0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12_ecc","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5778-1gy00-0aa0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5778-1gy00-0aa0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5778-1gy00-0ab0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5778-1gy00-0ab0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5778-1gy00-0ta0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12_ecc","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5778-1gy00-0ta0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12_ecc","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5778-1gy00-0tb0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12_ecc","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5778-1gy00-0tb0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12_ecc","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5786-1fc00-0aa0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5786-1fc00-0aa0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5786-1fc00-0ab0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5786-1fc00-0ab0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5786-2fc00-0aa0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5786-2fc00-0aa0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5786-2fc00-0ab0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5786-2fc00-0ab0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5786-2fc00-0ac0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5786-2fc00-0ac0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5786-2hc00-0aa0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5786-2hc00-0aa0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5786-2hc00-0ab0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5786-2hc00-0ab0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5788-1fc00-0aa0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5788-1fc00-0aa0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5788-1fc00-0ab0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5788-1fc00-0ab0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5788-1gd00-0aa0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5788-1gd00-0aa0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5788-1gd00-0ab0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5788-1gd00-0ab0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5788-2fc00-0aa0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5788-2fc00-0aa0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5788-2fc00-0ab0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5788-2fc00-0ab0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5788-2fc00-0ac0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5788-2fc00-0ac0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"rj45","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5788-2gd00-0aa0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5788-2gd00-0aa0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5788-2gd00-0ab0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5788-2gd00-0ab0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5788-2gd00-0ta0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12_ecc","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5788-2gd00-0ta0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12_ecc","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5788-2gd00-0tb0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12_ecc","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5788-2gd00-0tb0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12_ecc","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"6gk5788-2gd00-0tc0","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12_ecc","cpe13":"*"},{"cve_year":"2020","cve_id":"26141","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"6gk5788-2gd00-0tc0_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"m12_ecc","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2020","cve_id":"26141","cve":"CVE-2020-26141","epss":"0.002360000","percentile":"0.466190000","score_date":"2026-04-15","updated_at":"2026-04-16 00:13:56"},"legacy_qids":[{"cve":"CVE-2020-26141","qid":"159338","title":"Oracle Enterprise Linux Security Update for Unbreakable Enterprise kernel (ELSA-2021-9404)"},{"cve":"CVE-2020-26141","qid":"159339","title":"Oracle Enterprise Linux Security Update for Unbreakable Enterprise kernel-container (ELSA-2021-9406)"},{"cve":"CVE-2020-26141","qid":"159403","title":"Oracle Enterprise Linux Security Update for Unbreakable Enterprise kernel (ELSA-2021-9459)"},{"cve":"CVE-2020-26141","qid":"159492","title":"Oracle Enterprise Linux Security Update for kernel (ELSA-2021-4356)"},{"cve":"CVE-2020-26141","qid":"198416","title":"Ubuntu Security Notification for Linux kernel vulnerabilities (USN-4997-1)"},{"cve":"CVE-2020-26141","qid":"198417","title":"Ubuntu Security Notification for Linux kernel vulnerabilities (USN-4999-1)"},{"cve":"CVE-2020-26141","qid":"198418","title":"Ubuntu Security Notification for Linux kernel vulnerabilities (USN-5000-1)"},{"cve":"CVE-2020-26141","qid":"198419","title":"Ubuntu Security Notification for Linux kernel (OEM) vulnerabilities (USN-5001-1)"},{"cve":"CVE-2020-26141","qid":"198425","title":"Ubuntu Security Notification for Linux kernel (KVM) vulnerabilities (USN-5000-2)"},{"cve":"CVE-2020-26141","qid":"198426","title":"Ubuntu Security Notification for Linux kernel (KVM) vulnerabilities (USN-4997-2)"},{"cve":"CVE-2020-26141","qid":"239816","title":"Red Hat Update for kernel security (RHSA-2021:4356)"},{"cve":"CVE-2020-26141","qid":"239879","title":"Red Hat Update for kernel-rt (RHSA-2021:4140)"},{"cve":"CVE-2020-26141","qid":"353147","title":"Amazon Linux Security Advisory for kernel : ALAS2KERNEL-5.4-2022-004"},{"cve":"CVE-2020-26141","qid":"353158","title":"Amazon Linux Security Advisory for kernel : ALAS2KERNEL-5.10-2022-002"},{"cve":"CVE-2020-26141","qid":"390248","title":"Oracle Managed Virtualization (VM) Server for x86 Security Update for kernel (OVMSA-2021-0035)"},{"cve":"CVE-2020-26141","qid":"591035","title":"Siemens SCALANCE FragAttacks Multiple Vulnerabilities (ICSA-22-104-04) (SSA-913875)"},{"cve":"CVE-2020-26141","qid":"591150","title":"Hitachi ABB Power Grids TropOS Multiple Vulnerabilities (ICSA-21-236-01,9AKK107992A4463)"},{"cve":"CVE-2020-26141","qid":"610373","title":"Google Android Devices October 2021 Security Patch Missing"},{"cve":"CVE-2020-26141","qid":"610381","title":"Google Android November 2021 Security Patch Missing for Huawei EMUI"},{"cve":"CVE-2020-26141","qid":"610382","title":"Google Android November 2021 Security Patch Missing for Samsung"},{"cve":"CVE-2020-26141","qid":"610383","title":"Google Android November 2021 Security Patch Missing for LGE"},{"cve":"CVE-2020-26141","qid":"671051","title":"EulerOS Security Update for kernel (EulerOS-SA-2021-2663)"},{"cve":"CVE-2020-26141","qid":"671441","title":"EulerOS Security Update for kernel (EulerOS-SA-2022-1366)"},{"cve":"CVE-2020-26141","qid":"671703","title":"EulerOS Security Update for kernel (EulerOS-SA-2022-1735)"},{"cve":"CVE-2020-26141","qid":"750117","title":"SUSE Enterprise Linux Security Update for the Linux Kernel (SUSE-SU-2021:1891-1)"},{"cve":"CVE-2020-26141","qid":"750118","title":"SUSE Enterprise Linux Security Update for the Linux Kernel (SUSE-SU-2021:1890-1)"},{"cve":"CVE-2020-26141","qid":"750121","title":"SUSE Enterprise Linux Security Update for the Linux Kernel (SUSE-SU-2021:1888-1)"},{"cve":"CVE-2020-26141","qid":"750125","title":"SUSE Enterprise Linux Security Update for the Linux Kernel (SUSE-SU-2021:1887-1)"},{"cve":"CVE-2020-26141","qid":"750126","title":"SUSE Enterprise Linux Security Update for the Linux Kernel (SUSE-SU-2021:1889-1)"},{"cve":"CVE-2020-26141","qid":"750139","title":"SUSE Enterprise Linux Security Update for the Linux Kernel (SUSE-SU-2021:1913-1)"},{"cve":"CVE-2020-26141","qid":"750140","title":"SUSE Enterprise Linux Security Update for the Linux Kernel (SUSE-SU-2021:1912-1)"},{"cve":"CVE-2020-26141","qid":"750171","title":"OpenSUSE Security Update for the Linux Kernel (openSUSE-SU-2021:0843-1)"},{"cve":"CVE-2020-26141","qid":"750650","title":"SUSE Enterprise Linux Security Update for the Linux Kernel (SUSE-SU-2021:1975-1)"},{"cve":"CVE-2020-26141","qid":"750652","title":"SUSE Enterprise Linux Security Update for the Linux Kernel (SUSE-SU-2021:1977-1)"},{"cve":"CVE-2020-26141","qid":"750741","title":"OpenSUSE Security Update for the Linux Kernel (openSUSE-SU-2021:0947-1)"},{"cve":"CVE-2020-26141","qid":"750762","title":"OpenSUSE Security Update for the Linux Kernel (openSUSE-SU-2021:1977-1)"},{"cve":"CVE-2020-26141","qid":"750766","title":"OpenSUSE Security Update for the Linux Kernel (openSUSE-SU-2021:1975-1)"},{"cve":"CVE-2020-26141","qid":"750864","title":"SUSE Enterprise Linux Security Update for the Linux Kernel (SUSE-SU-2021:2421-1)"},{"cve":"CVE-2020-26141","qid":"750880","title":"SUSE Enterprise Linux Security Update for the Linux Kernel (SUSE-SU-2021:2451-1)"},{"cve":"CVE-2020-26141","qid":"940265","title":"AlmaLinux Security Update for kernel (ALSA-2021:4356)"}]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-04T15:49:07.134Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"name":"20210511 Multiple Vulnerabilities in Frame Aggregation and Fragmentation Implementations of 802.11 Specification Affecting Cisco Products: May 2021","tags":["vendor-advisory","x_refsource_CISCO","x_transferred"],"url":"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWu"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.fragattacks.com"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md"},{"name":"[oss-security] 20210511 various 802.11 security issues - fragattacks.com","tags":["mailing-list","x_refsource_MLIST","x_transferred"],"url":"http://www.openwall.com/lists/oss-security/2021/05/11/12"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63"}],"title":"CVE Program Container"},{"affected":[{"defaultStatus":"unknown","product":"SCALANCE W721-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W721-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W721-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W721-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W722-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W722-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W722-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W722-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W722-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W722-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45 (USA)","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45 (USA)","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W738-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W738-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W738-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W738-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W761-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W761-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W761-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W761-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45 (USA)","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45 (USA)","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12 EEC (USA)","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12 EEC (USA)","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 SFP","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 SFP","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 SFP","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 SFP","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2IA RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2IA RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2IA RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2IA RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]}],"providerMetadata":{"dateUpdated":"2026-04-14T08:49:04.995Z","orgId":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","shortName":"siemens-SADP"},"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-913875.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-019200.html"}],"x_adpType":"supplier"}],"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"descriptions":[{"lang":"en","value":"An issue was discovered in the ALFA Windows 10 driver 6.1316.1209 for AWUS036H. The Wi-Fi implementation does not verify the Message Integrity Check (authenticity) of fragmented TKIP frames. An adversary can abuse this to inject and possibly decrypt packets in WPA or WPA2 networks that support the TKIP data-confidentiality protocol."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2021-10-28T14:13:01.000Z","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre"},"references":[{"name":"20210511 Multiple Vulnerabilities in Frame Aggregation and Fragmentation Implementations of 802.11 Specification Affecting Cisco Products: May 2021","tags":["vendor-advisory","x_refsource_CISCO"],"url":"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWu"},{"tags":["x_refsource_MISC"],"url":"https://www.fragattacks.com"},{"tags":["x_refsource_MISC"],"url":"https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md"},{"name":"[oss-security] 20210511 various 802.11 security issues - fragattacks.com","tags":["mailing-list","x_refsource_MLIST"],"url":"http://www.openwall.com/lists/oss-security/2021/05/11/12"},{"tags":["x_refsource_CONFIRM"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf"},{"tags":["x_refsource_MISC"],"url":"https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2020-26141","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An issue was discovered in the ALFA Windows 10 driver 6.1316.1209 for AWUS036H. The Wi-Fi implementation does not verify the Message Integrity Check (authenticity) of fragmented TKIP frames. An adversary can abuse this to inject and possibly decrypt packets in WPA or WPA2 networks that support the TKIP data-confidentiality protocol."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"20210511 Multiple Vulnerabilities in Frame Aggregation and Fragmentation Implementations of 802.11 Specification Affecting Cisco Products: May 2021","refsource":"CISCO","url":"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWu"},{"name":"https://www.fragattacks.com","refsource":"MISC","url":"https://www.fragattacks.com"},{"name":"https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md","refsource":"MISC","url":"https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md"},{"name":"[oss-security] 20210511 various 802.11 security issues - fragattacks.com","refsource":"MLIST","url":"http://www.openwall.com/lists/oss-security/2021/05/11/12"},{"name":"https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf","refsource":"CONFIRM","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf"},{"name":"https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63","refsource":"MISC","url":"https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63"}]}}}},"cveMetadata":{"assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","assignerShortName":"mitre","cveId":"CVE-2020-26141","datePublished":"2021-05-11T19:42:11.000Z","dateReserved":"2020-09-29T00:00:00.000Z","dateUpdated":"2026-04-14T08:49:04.995Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2021-05-11 20:15:08","lastModifiedDate":"2026-04-14 09:16:23","problem_types":["CWE-354","n/a"],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:A/AC:L/Au:N/C:N/I:P/A:N","baseScore":3.3,"accessVector":"ADJACENT_NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"LOW","exploitabilityScore":6.5,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alfa:awus036h_firmware:6.1316.1209:*:*:*:*:windows_10:*:*","matchCriteriaId":"8A9FCD5B-54DD-4EF7-AB08-56EDE3B35E7B"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:alfa:awus036h:-:*:*:*:*:*:*:*","matchCriteriaId":"BF0F9200-8AFD-4100-AF39-49476298C0E3"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_gr10_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"27.7.1","matchCriteriaId":"2AED716A-D252-4FE8-ABE7-57D2AB3682ED"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_gr10:-:*:*:*:*:*:*:*","matchCriteriaId":"5EF406E2-A24B-4D94-B4F7-2186B1D82462"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_gr60_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"27.7.1","matchCriteriaId":"518B205F-78E7-48AD-A520-A799FCE11772"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_gr60:-:*:*:*:*:*:*:*","matchCriteriaId":"33B44092-CC37-4683-920D-8F84C60CCCEF"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr20_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"27.7.1","matchCriteriaId":"12785A53-15D1-46F4-8F51-2DE8B91C5EEA"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr20:-:*:*:*:*:*:*:*","matchCriteriaId":"07B1207B-C065-483D-8AB3-6B9CEC4D3C7C"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr30h_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"27.7.1","matchCriteriaId":"C22FD7BD-450D-4F81-AD5A-4CFD898EC86A"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr30h:-:*:*:*:*:*:*:*","matchCriteriaId":"602DA0AF-86EB-4A01-BDE3-43596DEC746A"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr33_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"27.7.1","matchCriteriaId":"22306637-577A-48D0-840B-9BD36D116D6E"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr33:-:*:*:*:*:*:*:*","matchCriteriaId":"12E670DC-C4D2-4277-A4DD-222D60A7CDB1"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr36_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"27.7.1","matchCriteriaId":"49C36428-65A0-4CA9-A0D3-093547A5A713"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr36:-:*:*:*:*:*:*:*","matchCriteriaId":"8A66108F-5CED-4D41-8EE9-9479090B31DD"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr42_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"27.7.1","matchCriteriaId":"676032C5-EE2F-4B58-BD5E-AA626E6B0C3D"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr42:-:*:*:*:*:*:*:*","matchCriteriaId":"18E7D194-AA15-43CD-9019-7B286F528773"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr42e_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"27.7.1","matchCriteriaId":"C2A55C08-73C3-42E7-86EE-A69DE10C2E8C"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr42e:-:*:*:*:*:*:*:*","matchCriteriaId":"6FB4754D-3B94-42AA-A150-6BDFF42B3270"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr44_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"27.7.1","matchCriteriaId":"630DCA1A-4F22-4F17-9205-6BFB0276B98A"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr44:-:*:*:*:*:*:*:*","matchCriteriaId":"07E495B6-CA7A-4F58-99A2-550F83E1E020"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr45_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"27.7.1","matchCriteriaId":"A323D6A6-386D-4CBD-B447-2EB18339F6CC"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr45:-:*:*:*:*:*:*:*","matchCriteriaId":"C4F47740-D0F3-478B-AFC3-51EB3AED34A4"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr46_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"27.7.1","matchCriteriaId":"6560ADD7-3655-4A85-A24E-1A9CC132C6AD"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr46:-:*:*:*:*:*:*:*","matchCriteriaId":"27E9718F-E50B-412F-86D7-DA6F39056006"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr46e_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"27.7.1","matchCriteriaId":"6F285B53-44CE-4158-A773-99F799F6CBCB"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr46e:-:*:*:*:*:*:*:*","matchCriteriaId":"B6B83072-84F6-43A4-9CC1-32924AFCC737"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr52_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"27.7.1","matchCriteriaId":"3D645D23-2B8F-4AC4-89BA-E070F3292958"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr52:-:*:*:*:*:*:*:*","matchCriteriaId":"5634D1AB-B64D-44D0-A431-FE52E879B4BD"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr53_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"27.7.1","matchCriteriaId":"6E1419FD-D693-42A5-ABC1-0539FB8BAD67"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr53:-:*:*:*:*:*:*:*","matchCriteriaId":"920CF4B6-9424-48DA-9622-FB0C0510E52F"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr53e_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"27.7.1","matchCriteriaId":"39D18FA7-E7D6-4F1C-BDE0-EB9526857BAD"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr53e:-:*:*:*:*:*:*:*","matchCriteriaId":"3EC322AE-6731-41F3-9C59-8CF9622D997A"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr55_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"27.7.1","matchCriteriaId":"7FE9C2A6-22E8-43A1-9936-EE65C0A342D3"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr55:-:*:*:*:*:*:*:*","matchCriteriaId":"C0036877-C975-4AC7-B933-E5BC5E300B44"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr56_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"27.7.1","matchCriteriaId":"092DA889-B167-41F3-81D7-B2F5BE7B99AF"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr56:-:*:*:*:*:*:*:*","matchCriteriaId":"E37474E5-76DE-4326-A5A8-D8900A8A2F62"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr70_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"27.7.1","matchCriteriaId":"A563D688-3994-4A14-AAEA-A45525D4C380"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr70:-:*:*:*:*:*:*:*","matchCriteriaId":"37D7E013-920A-4C32-98C1-FBD7C450DD88"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr74_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"27.7.1","matchCriteriaId":"BC333668-F713-4E20-97A6-A2192BF34964"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr74:-:*:*:*:*:*:*:*","matchCriteriaId":"366ABABA-D9C5-4D46-9516-7262AA32D4CD"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr76_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"27.7.1","matchCriteriaId":"02148C0F-306F-4700-8657-45134F43E2C4"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr76:-:*:*:*:*:*:*:*","matchCriteriaId":"D071FC26-097A-432B-8900-DA02D3116D29"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr84_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"27.7.1","matchCriteriaId":"04C4F44A-8E87-403B-BAD9-E6D6557496CB"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr84:-:*:*:*:*:*:*:*","matchCriteriaId":"9543B910-A999-4CEF-B06A-3F1A46784BF0"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr86_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"27.7.1","matchCriteriaId":"6BEF9B49-78E7-49C8-BADD-933EA12EA168"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr86:-:*:*:*:*:*:*:*","matchCriteriaId":"A57AA24E-09E0-4EB6-9580-A68267767119"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr12_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"26.8.3","matchCriteriaId":"0DE98041-599C-4B5E-9C52-234BA84E2731"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr12:-:*:*:*:*:*:*:*","matchCriteriaId":"03F4DBFC-42FC-44FD-9EDF-4C0C92053E4B"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr18_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"26.8.3","matchCriteriaId":"7AEF2C9C-2F99-49C9-95B8-93B0BDE5D777"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr18:-:*:*:*:*:*:*:*","matchCriteriaId":"9EC44D14-CF82-4C9A-A399-A3B7168F1F09"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr26_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"26.8.3","matchCriteriaId":"75A2E923-646F-4581-BE93-FBB3BD1A9814"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr26:-:*:*:*:*:*:*:*","matchCriteriaId":"60D19311-A114-455C-9011-004446C80E27"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr32_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"26.8.3","matchCriteriaId":"45A20191-7126-4B98-951F-2ACC03AAC227"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr32:-:*:*:*:*:*:*:*","matchCriteriaId":"E011F146-3AB9-446D-ACFD-FE5B021735D3"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr34_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"26.8.3","matchCriteriaId":"51590073-ACF5-42CC-9765-7DD358E03D40"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr34:-:*:*:*:*:*:*:*","matchCriteriaId":"814ADA42-72A9-48D6-B524-5F5BD76F3059"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr62_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"26.8.3","matchCriteriaId":"42F88F22-B587-44C9-A0A3-70EBDE310932"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr62:-:*:*:*:*:*:*:*","matchCriteriaId":"2F8F3095-F280-44B0-8BC6-50221247ACE1"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr66_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"26.8.3","matchCriteriaId":"893DB2E2-505C-45A4-8CD0-A911DC6F8C39"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr66:-:*:*:*:*:*:*:*","matchCriteriaId":"CBB99337-4422-46AB-9B79-A96CE207AC28"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mr72_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"26.8.3","matchCriteriaId":"BB69DA2F-0922-4FF4-B199-57F9C2E804B4"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mr72:-:*:*:*:*:*:*:*","matchCriteriaId":"68086DA9-AD50-41DC-B8B5-D9BB0512C6B6"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mx64w_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"17.0","matchCriteriaId":"C2274DBC-9BA6-4430-9E88-05027947FCBF"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mx64w:-:*:*:*:*:*:*:*","matchCriteriaId":"B1038F5F-020D-41FD-9C3D-F2685F1EA916"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mx65w_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"17.0","matchCriteriaId":"56D2B98B-9080-4DD2-841F-664EDE48D843"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mx65w:-:*:*:*:*:*:*:*","matchCriteriaId":"69A23113-F7E1-4587-A4FF-A4AAB446A69D"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mx67w_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"17.0","matchCriteriaId":"2D7F4EB0-2C74-4045-B5A5-9D71A8BCC8C9"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mx67w:-:*:*:*:*:*:*:*","matchCriteriaId":"F2529662-8A54-4DFC-80E7-922CF22DE2F3"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mx67cw_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"17.0","matchCriteriaId":"7855CB23-DD12-499A-B684-3FB3C893A809"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mx67cw:-:*:*:*:*:*:*:*","matchCriteriaId":"E85585DA-C918-445B-9B44-B2B1A982A1F7"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mx68w_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"17.0","matchCriteriaId":"47E66153-A0EE-49F7-B168-C953E390214E"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mx68w:-:*:*:*:*:*:*:*","matchCriteriaId":"03F9C184-3811-4A26-846D-54ECE7CF939F"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_mx68cw_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"17.0","matchCriteriaId":"77A69E5B-2C69-4769-94EE-02C70F270928"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_mx68cw:-:*:*:*:*:*:*:*","matchCriteriaId":"18E682AA-05AD-483F-915F-A2B2C98233B7"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_z3_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"17.0","matchCriteriaId":"85AD2B76-0B4E-434D-89F3-690E13B61B3B"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_z3:-:*:*:*:*:*:*:*","matchCriteriaId":"FB81CFD0-9558-47AB-96E4-CB21C1AA9159"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:meraki_z3c_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"17.0","matchCriteriaId":"42B92043-5436-4CA1-A297-DE88A5631BDC"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:meraki_z3c:-:*:*:*:*:*:*:*","matchCriteriaId":"6646F004-E0E0-4316-A022-2793C28FBCCC"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:wireless_ip_phone_8821_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"11.0\\(6\\)sr2","matchCriteriaId":"59A19DB2-1E3A-40AC-B265-878E9B568E8C"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:wireless_ip_phone_8821:-:*:*:*:*:*:*:*","matchCriteriaId":"F97DF354-7690-417E-B223-72C8BDA36DA7"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:ip_phone_6861_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"11.3\\(5\\)","matchCriteriaId":"B261F994-59CA-45F1-ACAC-8F4E93C94C64"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:ip_phone_6861:-:*:*:*:*:*:*:*","matchCriteriaId":"C05A7CA6-AD58-45D7-AF32-129E22855D8E"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:ip_phone_8861_firmware:*:*:*:*:*:3pcc:*:*","versionEndExcluding":"11.3\\(5\\)","matchCriteriaId":"13D13E34-A8AA-46F4-A0E3-E79D4513EFFA"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:ip_phone_8861:-:*:*:*:*:3pcc:*:*","matchCriteriaId":"77FC1162-9241-4605-8E0A-F9AC7F5F94E3"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:ip_phone_8861_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"14.1\\(1\\)","matchCriteriaId":"F1E3B94C-BA7B-481A-AF4D-2FCF5E81D7B6"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:ip_phone_8861:-:*:*:*:*:*:*:*","matchCriteriaId":"090EE553-01D5-45F0-87A4-E1167F46EB77"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:ip_phone_8865_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"14.1\\(1\\)","matchCriteriaId":"E9A7F857-A3D7-43DA-8E94-FDA0EE542C39"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:ip_phone_8865:-:*:*:*:*:*:*:*","matchCriteriaId":"BB99B9AB-64B5-4989-9579-A1BB5D2D87EF"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:ip_conference_phone_8832_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"14.1\\(1\\)","matchCriteriaId":"3B9BC28D-0BC0-45CB-A87B-59F407F3A210"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:ip_conference_phone_8832:-:*:*:*:*:*:*:*","matchCriteriaId":"F1010D16-DC6E-47A6-8BF9-C1026D975E3D"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:webex_room_series_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.2\\(0\\)sr1","matchCriteriaId":"F052EA74-DB34-4FF0-9A55-4E117CAF7765"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:webex_room_series:-:*:*:*:*:*:*:*","matchCriteriaId":"0872EA42-38A9-45A5-94A6-747FEEE0E1D9"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:webex_desk_series_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.2\\(0\\)sr1","matchCriteriaId":"9A0DD3DA-5B3D-4435-990B-FF181130788B"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:webex_desk_series:-:*:*:*:*:*:*:*","matchCriteriaId":"14038A41-2C6F-4A1E-85A1-8692B9633C8F"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:webex_board_series_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"10.8.2.5","matchCriteriaId":"75ED1FFC-A550-4F59-B4AE-FE8B0261E1AE"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:webex_board_series:-:*:*:*:*:*:*:*","matchCriteriaId":"BBE3BDBD-4D85-4C2E-B02E-D7D71331AFC2"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:webex_wireless_phone_860_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.4\\(0\\)","matchCriteriaId":"C80751CD-A4EE-45F5-83B3-E5D24C274B98"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:webex_wireless_phone_860:-:*:*:*:*:*:*:*","matchCriteriaId":"DC3CC529-4C57-4A21-8936-FD4222F2D350"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:webex_wireless_phone_840_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.4\\(0\\)","matchCriteriaId":"336CF15F-5AD9-41FD-8606-1531F37FBE1E"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:webex_wireless_phone_840:-:*:*:*:*:*:*:*","matchCriteriaId":"922CC404-372F-4F14-B820-67473C0938FA"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5778-1gy00-0ab0_firmware:-:*:*:*:*:*:m12:*","matchCriteriaId":"D5BDAE9A-9065-4CAE-8031-D294F31E2946"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5778-1gy00-0ab0:-:*:*:*:*:*:m12:*","matchCriteriaId":"B6D89D68-199F-42E2-84D0-97D3FF59F05F"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5778-1gy00-0aa0_firmware:-:*:*:*:*:*:m12:*","matchCriteriaId":"0E2D01D5-2DE9-4AD9-93D9-9C44F08B2BEE"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5778-1gy00-0aa0:-:*:*:*:*:*:m12:*","matchCriteriaId":"21A17252-75C3-46B4-927A-124354169DC8"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5721-1fc00-0aa0_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"5A333C23-A56B-48F6-992E-3BF0BD93F730"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5721-1fc00-0aa0:-:*:*:*:*:*:rj45:*","matchCriteriaId":"F941751F-76BB-4B0B-88B6-CFDBEA4FC2A7"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5721-1fc00-0ab0_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"867FE297-7913-43B1-AFF5-A4345FE7DF62"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5721-1fc00-0ab0:-:*:*:*:*:*:rj45:*","matchCriteriaId":"EB4AEAD7-F842-4E6E-9F44-73356C1874AF"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5722-1fc00-0aa0_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"840CD560-0324-41FB-B51E-77AEEEDC86BC"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5722-1fc00-0aa0:-:*:*:*:*:*:rj45:*","matchCriteriaId":"B9CFC662-6AA7-4528-B7DF-1ABF16DF0DAB"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5722-1fc00-0ab0_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"2EB47ED3-1063-4A3F-B4BB-8671CE96E0B0"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5722-1fc00-0ab0:-:*:*:*:*:*:rj45:*","matchCriteriaId":"664E9B08-2FA7-4257-B4DA-E3BB510E1E7A"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5722-1fc00-0ac0_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"E7DCBC95-FEC1-40B3-A81D-179FC97EFEBB"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5722-1fc00-0ac0:-:*:*:*:*:*:rj45:*","matchCriteriaId":"626DA25C-2DCA-4BFD-8A55-85BD1321D79F"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5734-1fx00-0aa0_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"EF32DD9B-2036-49AD-9547-956CAE3CD785"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5734-1fx00-0aa0:-:*:*:*:*:*:rj45:*","matchCriteriaId":"54DFFDC5-6BB7-4C97-B531-E6FD3CC7A533"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5734-1fx00-0aa6_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"4B303C52-44D8-4AA6-87C7-2659F7C1610E"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5734-1fx00-0aa6:-:*:*:*:*:*:rj45:*","matchCriteriaId":"7F935667-D4C4-45BE-9D39-9B7A40BD80A9"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5734-1fx00-0ab0_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"FF6314D0-5604-4CD1-8C5F-134AC492483E"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5734-1fx00-0ab0:-:*:*:*:*:*:rj45:*","matchCriteriaId":"5F103B12-A8CD-4B32-BFE3-940E3B4E7317"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5734-1fx00-0ab6_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"5B894E95-F49A-42ED-888D-4727F41F1A63"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5734-1fx00-0ab6:-:*:*:*:*:*:rj45:*","matchCriteriaId":"6F7BFBE4-92CA-4D23-8136-605C83B7E66C"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5738-1gy00-0aa0_firmware:-:*:*:*:*:*:m12:*","matchCriteriaId":"F083F822-DDE4-4D14-81F0-4EFD60DB13CD"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5738-1gy00-0aa0:-:*:*:*:*:*:m12:*","matchCriteriaId":"377B769F-0394-4E64-BF82-AAB8ADE562B8"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5738-1gy00-0ab0_firmware:-:*:*:*:*:*:m12:*","matchCriteriaId":"8BB35C1E-C9E7-4803-9AC1-ADFCBCA1052E"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5738-1gy00-0ab0:-:*:*:*:*:*:m12:*","matchCriteriaId":"49160650-CDA3-4E4C-BE42-BB84EB19F7E5"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5748-1fc00-0aa0_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"F6D3DD37-BAF7-4DBD-85D6-A6FEAE19DFFE"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5748-1fc00-0aa0:-:*:*:*:*:*:rj45:*","matchCriteriaId":"6E04CD9F-35B4-4E99-821F-D219980AE2CA"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5748-1fc00-0ab0_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"285EA838-3D9B-46EE-A9DB-9349500FC3D3"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5748-1fc00-0ab0:-:*:*:*:*:*:rj45:*","matchCriteriaId":"70DE2F72-4AB0-4D0C-AD1F-4D924CB6784C"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5748-1gd00-0aa0_firmware:-:*:*:*:*:*:m12:*","matchCriteriaId":"362FFD56-CFBF-4F66-974F-41FEE79D15AB"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5748-1gd00-0aa0:-:*:*:*:*:*:m12:*","matchCriteriaId":"C34A9FA4-119C-4B3A-BA67-B7305ED073A0"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5748-1gd00-0ab0_firmware:-:*:*:*:*:*:m12:*","matchCriteriaId":"D5CD5D61-1DF5-4B1B-8F9B-8786563BE8E3"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5748-1gd00-0ab0:-:*:*:*:*:*:m12:*","matchCriteriaId":"8B7DAEE3-5390-4981-A577-991A42696AC9"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5761-1fc00-0aa0_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"2E784308-225C-4FD1-87AF-A2D052CD87A4"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5761-1fc00-0aa0:-:*:*:*:*:*:rj45:*","matchCriteriaId":"62F306FD-D399-4D3B-9F4A-6605B035DFE9"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5761-1fc00-0ab0_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"792D3327-54FF-4DF1-826C-670C2B91DAC6"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5761-1fc00-0ab0:-:*:*:*:*:*:rj45:*","matchCriteriaId":"4BE9B963-6B95-49DC-A499-3DE4DC269036"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5774-1fx00-0aa0_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"7EED502F-EBE4-4DED-822E-8CA310A354B4"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5774-1fx00-0aa0:-:*:*:*:*:*:rj45:*","matchCriteriaId":"3C8D09C4-AB99-498A-BDA9-20F040BA57B8"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5774-1fx00-0aa6_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"EEF16762-3BCD-4908-BDFC-EE1DC34023D5"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5774-1fx00-0aa6:-:*:*:*:*:*:rj45:*","matchCriteriaId":"3DAC6CD0-C5D8-4C87-BC35-93E49FDFB55B"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5774-1fx00-0ab0_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"ADAF404C-8334-4754-90B6-5C1E6CCD1F76"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5774-1fx00-0ab0:-:*:*:*:*:*:rj45:*","matchCriteriaId":"AAF3FA1B-6774-4AC1-B040-BE5815859FD2"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5774-1fx00-0ab6_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"92E3C47A-CCF6-4B3B-9B08-5D03186C817D"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5774-1fx00-0ab6:-:*:*:*:*:*:rj45:*","matchCriteriaId":"EC1F4E15-3C06-4133-8435-1A76ACD6EF62"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5774-1fy00-0ta0_firmware:-:*:*:*:*:*:m12_ecc:*","matchCriteriaId":"403F0AD8-E663-479C-A45B-352B257F0247"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5774-1fy00-0ta0:-:*:*:*:*:*:m12_ecc:*","matchCriteriaId":"21439D8A-680E-489E-A1E2-4C31B49E82BF"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5774-1fy00-0tb0_firmware:-:*:*:*:*:*:m12_ecc:*","matchCriteriaId":"DF180BB2-E8DD-4B9C-92C4-A8DD5EB83446"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5774-1fy00-0tb0:-:*:*:*:*:*:m12_ecc:*","matchCriteriaId":"A2C0E215-F905-4B16-9D80-81B440BA1F8F"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5778-1gy00-0ta0_firmware:-:*:*:*:*:*:m12_ecc:*","matchCriteriaId":"9CD6B350-BA19-407D-9956-51D27A2E311C"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5778-1gy00-0ta0:-:*:*:*:*:*:m12_ecc:*","matchCriteriaId":"EA5D4E3B-48CE-4C4A-A09E-FAEE74720091"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5778-1gy00-0tb0_firmware:-:*:*:*:*:*:m12_ecc:*","matchCriteriaId":"57ECC858-88F1-4456-B7ED-D3B1847F354C"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5778-1gy00-0tb0:-:*:*:*:*:*:m12_ecc:*","matchCriteriaId":"5415EDBC-1FAB-486B-B874-B7D35860013F"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5786-1fc00-0aa0_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"7CB72EAF-7D3E-4C4F-A72D-9D1D085EC32A"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5786-1fc00-0aa0:-:*:*:*:*:*:rj45:*","matchCriteriaId":"889744B0-52CE-49BB-99BA-4B2B668DC3C2"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5786-1fc00-0ab0_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"3A12493B-2032-4F3A-A994-B502BF0EC814"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5786-1fc00-0ab0:-:*:*:*:*:*:rj45:*","matchCriteriaId":"774C7E40-0B01-4C1E-8EED-4E8A91B73E28"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5786-2fc00-0aa0_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"4E36CEFB-337C-4AD2-AAAC-43EF62E0E014"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5786-2fc00-0aa0:-:*:*:*:*:*:rj45:*","matchCriteriaId":"1E4695C5-F117-42A2-B3A2-50D4777EBA53"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5786-2fc00-0ab0_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"0C284514-F681-4B9E-9A1F-D3F7BE9B5C0F"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5786-2fc00-0ab0:-:*:*:*:*:*:rj45:*","matchCriteriaId":"851ECBFD-AC30-46BD-82F9-267A11199D06"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5786-2fc00-0ac0_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"2F31CE93-B417-41B0-8060-3116347424A0"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5786-2fc00-0ac0:-:*:*:*:*:*:rj45:*","matchCriteriaId":"DF581904-415F-4D9E-9A86-5342DE2FD4D8"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5786-2hc00-0aa0_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"F0306E3A-302F-4F70-8358-C13824F023E7"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5786-2hc00-0aa0:-:*:*:*:*:*:rj45:*","matchCriteriaId":"75A4F315-14FB-4E93-B74D-9E52682A6B0A"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5786-2hc00-0ab0_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"0E5EAC53-E32C-41DB-A2ED-F7DDA8F1B49A"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5786-2hc00-0ab0:-:*:*:*:*:*:rj45:*","matchCriteriaId":"BB7605ED-2ABB-4206-8ABC-3C1C1999DF17"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5788-1fc00-0aa0_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"F640E706-6912-4675-A3D8-B98374CB3324"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5788-1fc00-0aa0:-:*:*:*:*:*:rj45:*","matchCriteriaId":"8808A2F3-ECDE-46D3-AD0F-02BE2735A6BD"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5788-1fc00-0ab0_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"2BB7F4C9-E24F-420B-9DCA-9E7994E05971"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5788-1fc00-0ab0:-:*:*:*:*:*:rj45:*","matchCriteriaId":"ADB85459-E2D7-4ED4-A0CB-17B68061E250"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5788-1gd00-0aa0_firmware:-:*:*:*:*:*:m12:*","matchCriteriaId":"EA798D9C-36A3-41C8-B9FC-8123EC9BF452"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5788-1gd00-0aa0:-:*:*:*:*:*:m12:*","matchCriteriaId":"64284790-C465-410F-B871-B0226725DDDF"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5788-1gd00-0ab0_firmware:-:*:*:*:*:*:m12:*","matchCriteriaId":"C7290D90-688D-4BE7-8089-095959EEC46E"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5788-1gd00-0ab0:-:*:*:*:*:*:m12:*","matchCriteriaId":"D5246D7B-63BF-48BC-A98D-5A0646FDE6DB"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5788-2fc00-0aa0_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"BC05A12F-5ADB-4AC4-BBA1-A319330340E3"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5788-2fc00-0aa0:-:*:*:*:*:*:rj45:*","matchCriteriaId":"54B39530-AE99-4BBA-8C59-FAC84DDEF33A"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5788-2fc00-0ab0_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"34480D85-D445-41FF-B0FD-5D722A487F4A"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5788-2fc00-0ab0:-:*:*:*:*:*:rj45:*","matchCriteriaId":"634ADAA3-8F4A-44A5-BC88-1ED3F1EE61C8"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5788-2fc00-0ac0_firmware:-:*:*:*:*:*:rj45:*","matchCriteriaId":"9474FF4F-F936-4E72-8482-5D1C9C49C890"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5788-2fc00-0ac0:-:*:*:*:*:*:rj45:*","matchCriteriaId":"317D4551-6400-4E4E-8AB4-9024E4BE72E2"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5788-2gd00-0aa0_firmware:-:*:*:*:*:*:m12:*","matchCriteriaId":"73CB46CC-6647-4AAF-B3C8-042C776B8532"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5788-2gd00-0aa0:-:*:*:*:*:*:m12:*","matchCriteriaId":"0C9A1C83-A000-456A-A443-ECCC4A5900DC"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5788-2gd00-0ab0_firmware:-:*:*:*:*:*:m12:*","matchCriteriaId":"55B91BF8-1086-4721-8829-3D017341A25A"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5788-2gd00-0ab0:-:*:*:*:*:*:m12:*","matchCriteriaId":"ED8212AE-EC38-4F46-84FB-042AE480E53A"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5788-2gd00-0ta0_firmware:-:*:*:*:*:*:m12_ecc:*","matchCriteriaId":"B94BFF37-65A3-4F80-81F4-85647B4C2441"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5788-2gd00-0ta0:-:*:*:*:*:*:m12_ecc:*","matchCriteriaId":"9D9494C4-C03A-4B92-95B9-7D68FE604257"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5788-2gd00-0tb0_firmware:-:*:*:*:*:*:m12_ecc:*","matchCriteriaId":"E4D701C5-F94E-4ECF-B0F2-477B7DF6630F"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5788-2gd00-0tb0:-:*:*:*:*:*:m12_ecc:*","matchCriteriaId":"EFEFA2DE-F621-41FA-AB8A-9DF1F3762311"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:6gk5788-2gd00-0tc0_firmware:-:*:*:*:*:*:m12_ecc:*","matchCriteriaId":"466CEF9A-C71A-41DC-AD74-21FBA163E97F"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:6gk5788-2gd00-0tc0:-:*:*:*:*:*:m12_ecc:*","matchCriteriaId":"B69D6A0A-EC16-41F1-A1E6-38FADD9A190D"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"26141","Ordinal":"1","Title":"CVE-2020-26141","CVE":"CVE-2020-26141","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"26141","Ordinal":"1","NoteData":"An issue was discovered in the ALFA Windows 10 driver 6.1316.1209 for AWUS036H. The Wi-Fi implementation does not verify the Message Integrity Check (authenticity) of fragmented TKIP frames. An adversary can abuse this to inject and possibly decrypt packets in WPA or WPA2 networks that support the TKIP data-confidentiality protocol.","Type":"Description","Title":"CVE-2020-26141"},{"CveYear":"2020","CveId":"26141","Ordinal":"2","NoteData":"2021-05-11","Type":"Other","Title":"Published"},{"CveYear":"2020","CveId":"26141","Ordinal":"3","NoteData":"2021-10-28","Type":"Other","Title":"Modified"}]}}}