{"api_version":"1","generated_at":"2026-04-22T23:30:30+00:00","cve":"CVE-2020-26146","urls":{"html":"https://cve.report/CVE-2020-26146","api":"https://cve.report/api/cve/CVE-2020-26146.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-26146","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-26146"},"summary":{"title":"CVE-2020-26146","description":"An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WPA, WPA2, and WPA3 implementations reassemble fragments with non-consecutive packet numbers. An adversary can abuse this to exfiltrate selected fragments. This vulnerability is exploitable when another device sends fragmented frames and the WEP, CCMP, or GCMP data-confidentiality protocol is used. Note that WEP is vulnerable to this attack by design.","state":"PUBLISHED","assigner":"mitre","published_at":"2021-05-11 20:15:08","updated_at":"2026-04-14 09:16:26"},"problem_types":["CWE-20","n/a"],"metrics":[{"version":"3.1","source":"nvd@nist.gov","type":"Primary","score":"5.3","severity":"MEDIUM","vector":"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N","baseScore":5.3,"baseSeverity":"MEDIUM","attackVector":"ADJACENT_NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"HIGH","availabilityImpact":"NONE"}},{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"2.9","severity":"","vector":"AV:A/AC:M/Au:N/C:N/I:P/A:N","data":{"version":"2.0","vectorString":"AV:A/AC:M/Au:N/C:N/I:P/A:N","baseScore":2.9,"accessVector":"ADJACENT_NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"}}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md","name":"https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"],"title":"fragattacks/SUMMARY.md at master · vanhoefm/fragattacks · GitHub","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-019200.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-019200.html","refsource":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.fragattacks.com","name":"https://www.fragattacks.com","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"],"title":"FragAttacks: Security flaws in all Wi-Fi devices","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-913875.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-913875.html","refsource":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63","name":"https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"],"title":"Security Advisory 0063 - Arista","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWu","name":"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWu","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"],"title":"Multiple Vulnerabilities in Frame Aggregation and Fragmentation Implementations of 802.11 Specification Affecting Cisco Products: May 2021","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.openwall.com/lists/oss-security/2021/05/11/12","name":"http://www.openwall.com/lists/oss-security/2021/05/11/12","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Mailing List","Third Party Advisory"],"title":"oss-security - various 802.11 security issues - fragattacks.com","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-26146","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-26146","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"n/a","version":"affected n/a","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W1748-1 M12","version":"affected V3.0.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W1748-1 M12","version":"affected V3.0.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W1750D (JP)","version":"affected V8.7.1.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W1750D (ROW)","version":"affected V8.7.1.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W1750D (USA)","version":"affected V8.7.1.3 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W1788-1 M12","version":"affected V3.0.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W1788-2 EEC M12","version":"affected V3.0.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W1788-2 M12","version":"affected V3.0.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W1788-2IA M12","version":"affected V3.0.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W721-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W721-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W721-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W721-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W722-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W722-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W722-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W722-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W722-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W722-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45 (USA)","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45 (USA)","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W738-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W738-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W738-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W738-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W761-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W761-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W761-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W761-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45 (USA)","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45 (USA)","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12 EEC (USA)","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12 EEC (USA)","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 SFP","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 SFP","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 SFP","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 SFP","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2IA RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2IA RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2IA RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2IA RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE WAM763-1","version":"affected V1.2.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE WAM766-1","version":"affected V1.2.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE WAM766-1 (US)","version":"affected V1.2.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE WAM766-1 EEC","version":"affected V1.2.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE WAM766-1 EEC (US)","version":"affected V1.2.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE WUM763-1","version":"affected V1.2.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE WUM763-1","version":"affected V1.2.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE WUM766-1","version":"affected V1.2.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE WUM766-1 (USA)","version":"affected V1.2.0 custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2020","cve_id":"26146","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"arista","cpe5":"c-100","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"arista","cpe5":"c-100_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"arista","cpe5":"c-110","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"arista","cpe5":"c-110_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"arista","cpe5":"c-120","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"arista","cpe5":"c-120_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"arista","cpe5":"c-130","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"arista","cpe5":"c-130_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"arista","cpe5":"c-200","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"arista","cpe5":"c-200_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"arista","cpe5":"c-230","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"arista","cpe5":"c-230_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"arista","cpe5":"c-235","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"arista","cpe5":"c-235_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"arista","cpe5":"c-250","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"arista","cpe5":"c-250_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"arista","cpe5":"c-260","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"arista","cpe5":"c-260_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"arista","cpe5":"c-65","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"arista","cpe5":"c-65_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"arista","cpe5":"c-75","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"arista","cpe5":"c-75_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"arista","cpe5":"o-105","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"arista","cpe5":"o-105_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"arista","cpe5":"o-90","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"arista","cpe5":"o-90_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"arista","cpe5":"w-118","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"arista","cpe5":"w-118_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"arista","cpe5":"w-68","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"arista","cpe5":"w-68_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"samsung","cpe5":"galaxy_i9305","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"samsung","cpe5":"galaxy_i9305_firmware","cpe6":"4.4.4","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"scalance_w1700_ieee_802.11ac","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"scalance_w1700_ieee_802.11ac_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"scalance_w1750d","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"scalance_w1750d_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"scalance_w700_ieee_802.11n","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"26146","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"scalance_w700_ieee_802.11n_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2020","cve_id":"26146","cve":"CVE-2020-26146","epss":"0.014090000","percentile":"0.805160000","score_date":"2026-04-15","updated_at":"2026-04-16 00:13:56"},"legacy_qids":[{"cve":"CVE-2020-26146","qid":"159403","title":"Oracle Enterprise Linux Security Update for Unbreakable Enterprise kernel (ELSA-2021-9459)"},{"cve":"CVE-2020-26146","qid":"159492","title":"Oracle Enterprise Linux Security Update for kernel (ELSA-2021-4356)"},{"cve":"CVE-2020-26146","qid":"239816","title":"Red Hat Update for kernel security (RHSA-2021:4356)"},{"cve":"CVE-2020-26146","qid":"239879","title":"Red Hat Update for kernel-rt (RHSA-2021:4140)"},{"cve":"CVE-2020-26146","qid":"390248","title":"Oracle Managed Virtualization (VM) Server for x86 Security Update for kernel (OVMSA-2021-0035)"},{"cve":"CVE-2020-26146","qid":"43828","title":"HPE ArubaOS Multiple Vulnerabilities (ARUBA-PSA-2021-011)"},{"cve":"CVE-2020-26146","qid":"591035","title":"Siemens SCALANCE FragAttacks Multiple Vulnerabilities (ICSA-22-104-04) (SSA-913875)"},{"cve":"CVE-2020-26146","qid":"591104","title":"Mitsubishi Electric GT25-WLAN (Update A) Multiple Vulnerabilities (ICSA-22-102-04)"},{"cve":"CVE-2020-26146","qid":"591150","title":"Hitachi ABB Power Grids TropOS Multiple Vulnerabilities (ICSA-21-236-01,9AKK107992A4463)"},{"cve":"CVE-2020-26146","qid":"610373","title":"Google Android Devices October 2021 Security Patch Missing"},{"cve":"CVE-2020-26146","qid":"610381","title":"Google Android November 2021 Security Patch Missing for Huawei EMUI"},{"cve":"CVE-2020-26146","qid":"610383","title":"Google Android November 2021 Security Patch Missing for LGE"},{"cve":"CVE-2020-26146","qid":"671441","title":"EulerOS Security Update for kernel (EulerOS-SA-2022-1366)"},{"cve":"CVE-2020-26146","qid":"671703","title":"EulerOS Security Update for kernel (EulerOS-SA-2022-1735)"},{"cve":"CVE-2020-26146","qid":"940265","title":"AlmaLinux Security Update for kernel (ALSA-2021:4356)"}]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-04T15:49:07.202Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"name":"20210511 Multiple Vulnerabilities in Frame Aggregation and Fragmentation Implementations of 802.11 Specification Affecting Cisco Products: May 2021","tags":["vendor-advisory","x_refsource_CISCO","x_transferred"],"url":"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWu"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.fragattacks.com"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md"},{"name":"[oss-security] 20210511 various 802.11 security issues - fragattacks.com","tags":["mailing-list","x_refsource_MLIST","x_transferred"],"url":"http://www.openwall.com/lists/oss-security/2021/05/11/12"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63"}],"title":"CVE Program Container"},{"affected":[{"defaultStatus":"unknown","product":"SCALANCE W1748-1 M12","vendor":"Siemens","versions":[{"lessThan":"V3.0.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W1748-1 M12","vendor":"Siemens","versions":[{"lessThan":"V3.0.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W1750D (JP)","vendor":"Siemens","versions":[{"lessThan":"V8.7.1.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W1750D (ROW)","vendor":"Siemens","versions":[{"lessThan":"V8.7.1.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W1750D (USA)","vendor":"Siemens","versions":[{"lessThan":"V8.7.1.3","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W1788-1 M12","vendor":"Siemens","versions":[{"lessThan":"V3.0.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W1788-2 EEC M12","vendor":"Siemens","versions":[{"lessThan":"V3.0.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W1788-2 M12","vendor":"Siemens","versions":[{"lessThan":"V3.0.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W1788-2IA M12","vendor":"Siemens","versions":[{"lessThan":"V3.0.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W721-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W721-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W721-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W721-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W722-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W722-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W722-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W722-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W722-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W722-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45 (USA)","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45 (USA)","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W738-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W738-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W738-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W738-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W761-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W761-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W761-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W761-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45 (USA)","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45 (USA)","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12 EEC (USA)","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12 EEC (USA)","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 SFP","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 SFP","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 SFP","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 SFP","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2IA RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2IA RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2IA RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2IA RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE WAM763-1","vendor":"Siemens","versions":[{"lessThan":"V1.2.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE WAM766-1","vendor":"Siemens","versions":[{"lessThan":"V1.2.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE WAM766-1 (US)","vendor":"Siemens","versions":[{"lessThan":"V1.2.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE WAM766-1 EEC","vendor":"Siemens","versions":[{"lessThan":"V1.2.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE WAM766-1 EEC (US)","vendor":"Siemens","versions":[{"lessThan":"V1.2.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE WUM763-1","vendor":"Siemens","versions":[{"lessThan":"V1.2.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE WUM763-1","vendor":"Siemens","versions":[{"lessThan":"V1.2.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE WUM766-1","vendor":"Siemens","versions":[{"lessThan":"V1.2.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE WUM766-1 (USA)","vendor":"Siemens","versions":[{"lessThan":"V1.2.0","status":"affected","version":"0","versionType":"custom"}]}],"providerMetadata":{"dateUpdated":"2026-04-14T08:49:11.814Z","orgId":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","shortName":"siemens-SADP"},"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-913875.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-019200.html"}],"x_adpType":"supplier"}],"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"descriptions":[{"lang":"en","value":"An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WPA, WPA2, and WPA3 implementations reassemble fragments with non-consecutive packet numbers. An adversary can abuse this to exfiltrate selected fragments. This vulnerability is exploitable when another device sends fragmented frames and the WEP, CCMP, or GCMP data-confidentiality protocol is used. Note that WEP is vulnerable to this attack by design."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2021-10-28T14:28:30.000Z","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre"},"references":[{"name":"20210511 Multiple Vulnerabilities in Frame Aggregation and Fragmentation Implementations of 802.11 Specification Affecting Cisco Products: May 2021","tags":["vendor-advisory","x_refsource_CISCO"],"url":"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWu"},{"tags":["x_refsource_MISC"],"url":"https://www.fragattacks.com"},{"tags":["x_refsource_MISC"],"url":"https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md"},{"name":"[oss-security] 20210511 various 802.11 security issues - fragattacks.com","tags":["mailing-list","x_refsource_MLIST"],"url":"http://www.openwall.com/lists/oss-security/2021/05/11/12"},{"tags":["x_refsource_CONFIRM"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf"},{"tags":["x_refsource_MISC"],"url":"https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2020-26146","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WPA, WPA2, and WPA3 implementations reassemble fragments with non-consecutive packet numbers. An adversary can abuse this to exfiltrate selected fragments. This vulnerability is exploitable when another device sends fragmented frames and the WEP, CCMP, or GCMP data-confidentiality protocol is used. Note that WEP is vulnerable to this attack by design."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"20210511 Multiple Vulnerabilities in Frame Aggregation and Fragmentation Implementations of 802.11 Specification Affecting Cisco Products: May 2021","refsource":"CISCO","url":"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWu"},{"name":"https://www.fragattacks.com","refsource":"MISC","url":"https://www.fragattacks.com"},{"name":"https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md","refsource":"MISC","url":"https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md"},{"name":"[oss-security] 20210511 various 802.11 security issues - fragattacks.com","refsource":"MLIST","url":"http://www.openwall.com/lists/oss-security/2021/05/11/12"},{"name":"https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf","refsource":"CONFIRM","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf"},{"name":"https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63","refsource":"MISC","url":"https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63"}]}}}},"cveMetadata":{"assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","assignerShortName":"mitre","cveId":"CVE-2020-26146","datePublished":"2021-05-11T19:39:07.000Z","dateReserved":"2020-09-29T00:00:00.000Z","dateUpdated":"2026-04-14T08:49:11.814Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2021-05-11 20:15:08","lastModifiedDate":"2026-04-14 09:16:26","problem_types":["CWE-20","n/a"],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N","baseScore":5.3,"baseSeverity":"MEDIUM","attackVector":"ADJACENT_NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":1.6,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:A/AC:M/Au:N/C:N/I:P/A:N","baseScore":2.9,"accessVector":"ADJACENT_NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"LOW","exploitabilityScore":5.5,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:samsung:galaxy_i9305_firmware:4.4.4:*:*:*:*:*:*:*","matchCriteriaId":"B5CFC281-DDBA-4511-A271-FCFFA337E2B9"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:samsung:galaxy_i9305:-:*:*:*:*:*:*:*","matchCriteriaId":"79194A52-BFFC-448B-9032-F29D2A5971BE"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:arista:c-250_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"10.0.1-31","matchCriteriaId":"B22D5837-A2CC-41AB-8252-1724345AEDC5"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:arista:c-250:-:*:*:*:*:*:*:*","matchCriteriaId":"EE97F0AD-8658-476A-8E22-DA67A5FD9F73"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:arista:c-260_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"10.0.1-31","matchCriteriaId":"4180BE58-3CA0-4FFD-B5BE-44E36FDE5F89"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:arista:c-260:-:*:*:*:*:*:*:*","matchCriteriaId":"A006A8BD-D56E-40C2-ADD2-C11759153808"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:arista:c-230_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"10.0.1-31","matchCriteriaId":"59BE4F3A-477A-4DE9-B293-F2AF2CCED9A3"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:arista:c-230:-:*:*:*:*:*:*:*","matchCriteriaId":"29B18F4E-4968-493A-BC90-5D8D7F619F39"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:arista:c-235_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"10.0.1-31","matchCriteriaId":"96A0A5F0-B046-4B53-92BC-D21705B1597C"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:arista:c-235:-:*:*:*:*:*:*:*","matchCriteriaId":"54878C0D-8842-490F-B556-76AF47A65891"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:arista:c-200_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"11.0.0-36","matchCriteriaId":"C62FEC63-9790-44DF-8AA0-050E89E883B1"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:arista:c-200:-:*:*:*:*:*:*:*","matchCriteriaId":"8F81C550-CE6F-4E68-A088-5EC0CEF40600"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:arista:c-120_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"11.0.0-36","matchCriteriaId":"DBABE602-480F-417B-8B5F-15312267FDF1"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:arista:c-120:-:*:*:*:*:*:*:*","matchCriteriaId":"AE3EC767-2ECA-44E4-AA03-9E2673A2B2F3"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:arista:c-130_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"11.0.0-36","matchCriteriaId":"FDF09C24-4E64-4365-994A-52001D3534B1"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:arista:c-130:-:*:*:*:*:*:*:*","matchCriteriaId":"81C15C55-207E-4030-AC2A-B2E3791D92B0"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:arista:c-100_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"11.0.0-36","matchCriteriaId":"42002393-9A4C-4409-9327-896F94FC1D75"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:arista:c-100:-:*:*:*:*:*:*:*","matchCriteriaId":"132AD177-3F7F-4CD7-9BD5-EE5A24CE671C"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:arista:c-110_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"11.0.0-36","matchCriteriaId":"FDB30A2A-BF19-4D82-A773-AFD64F2B2070"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:arista:c-110:-:*:*:*:*:*:*:*","matchCriteriaId":"C4E82587-A7A1-4057-896A-F30B9DF7C831"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:arista:o-105_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"11.0.0-36","matchCriteriaId":"FED1F85B-60E5-45C7-846B-956D91ECC0A6"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:arista:o-105:-:*:*:*:*:*:*:*","matchCriteriaId":"7A31FF47-55EE-451B-ABDD-CE82E8EFBC98"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:arista:w-118_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"11.0.0-36","matchCriteriaId":"D2658DB5-4E35-4F53-A278-CFA6DD3E683F"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:arista:w-118:-:*:*:*:*:*:*:*","matchCriteriaId":"5BEE861E-2604-42BD-ABAA-DA729F4EBDBC"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:arista:c-75_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"AD2A3CCF-E8B5-4E7F-BCE7-DB70E8E72B4B"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:arista:c-75:-:*:*:*:*:*:*:*","matchCriteriaId":"8EE26D5A-486B-48F3-9C1C-4EE3FD8F0234"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:arista:o-90_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"0B9860B5-6CC7-4F29-9514-A469AF6B28F1"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:arista:o-90:-:*:*:*:*:*:*:*","matchCriteriaId":"41F9E4B2-63FC-4F53-9C12-7478B7B6AD48"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:arista:c-65_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"8C890ABE-5D64-4D7F-A67B-BC026649E0B3"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:arista:c-65:-:*:*:*:*:*:*:*","matchCriteriaId":"6B617EA3-E69E-43CA-99D4-86A408C55C90"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:arista:w-68_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"1C1EF830-C210-48DB-A3F8-FC706AC5F3C7"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:arista:w-68:-:*:*:*:*:*:*:*","matchCriteriaId":"9F03BB48-C89A-41F6-99DE-12FF95DCD9F2"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_w700_ieee_802.11n_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"F05D6764-79B4-4787-B2D2-E685910453C3"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_w700_ieee_802.11n:-:*:*:*:*:*:*:*","matchCriteriaId":"880644DA-9280-4498-AD72-5CBD59CC8142"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_w1700_ieee_802.11ac_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"180881A1-AA78-411E-B508-D4C0D7084E28"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_w1700_ieee_802.11ac:-:*:*:*:*:*:*:*","matchCriteriaId":"55CA7B83-9295-451A-9B78-832761A6BA79"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_w1750d_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"8.7.1.3","matchCriteriaId":"B4603220-61F1-4686-B55D-F9F5D27F324A"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_w1750d:-:*:*:*:*:*:*:*","matchCriteriaId":"FBC30055-239F-4BB1-B2D1-E5E35F0D8911"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"26146","Ordinal":"1","Title":"CVE-2020-26146","CVE":"CVE-2020-26146","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"26146","Ordinal":"1","NoteData":"An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WPA, WPA2, and WPA3 implementations reassemble fragments with non-consecutive packet numbers. An adversary can abuse this to exfiltrate selected fragments. This vulnerability is exploitable when another device sends fragmented frames and the WEP, CCMP, or GCMP data-confidentiality protocol is used. Note that WEP is vulnerable to this attack by design.","Type":"Description","Title":"CVE-2020-26146"},{"CveYear":"2020","CveId":"26146","Ordinal":"2","NoteData":"2021-05-11","Type":"Other","Title":"Published"},{"CveYear":"2020","CveId":"26146","Ordinal":"3","NoteData":"2021-10-28","Type":"Other","Title":"Modified"}]}}}