{"api_version":"1","generated_at":"2026-04-22T21:37:41+00:00","cve":"CVE-2020-26147","urls":{"html":"https://cve.report/CVE-2020-26147","api":"https://cve.report/api/cve/CVE-2020-26147.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-26147","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-26147"},"summary":{"title":"CVE-2020-26147","description":"An issue was discovered in the Linux kernel 5.8.9. The WEP, WPA, WPA2, and WPA3 implementations reassemble fragments even though some of them were sent in plaintext. This vulnerability can be abused to inject packets and/or exfiltrate selected fragments when another device sends fragmented frames and the WEP, CCMP, or GCMP data-confidentiality protocol is used.","state":"PUBLISHED","assigner":"mitre","published_at":"2021-05-11 20:15:08","updated_at":"2026-04-14 10:16:18"},"problem_types":["NVD-CWE-Other","n/a"],"metrics":[{"version":"3.1","source":"nvd@nist.gov","type":"Primary","score":"5.4","severity":"MEDIUM","vector":"CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:N","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:N","baseScore":5.4,"baseSeverity":"MEDIUM","attackVector":"ADJACENT_NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"HIGH","availabilityImpact":"NONE"}},{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"3.2","severity":"","vector":"AV:A/AC:H/Au:N/C:P/I:P/A:N","data":{"version":"2.0","vectorString":"AV:A/AC:H/Au:N/C:P/I:P/A:N","baseScore":3.2,"accessVector":"ADJACENT_NETWORK","accessComplexity":"HIGH","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"NONE"}}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md","name":"https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"],"title":"fragattacks/SUMMARY.md at master · vanhoefm/fragattacks · GitHub","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-019200.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-019200.html","refsource":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://www.fragattacks.com","name":"https://www.fragattacks.com","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Product"],"title":"FragAttacks: Security flaws in all Wi-Fi devices","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-913875.html","name":"https://cert-portal.siemens.com/productcert/html/ssa-913875.html","refsource":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","tags":[],"title":"","mime":"","httpstatus":"","archivestatus":"0"},{"url":"https://lists.debian.org/debian-lts-announce/2021/06/msg00020.html","name":"https://lists.debian.org/debian-lts-announce/2021/06/msg00020.html","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Mailing List","Third Party Advisory"],"title":"[SECURITY] [DLA 2689-1] linux security update","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://lists.debian.org/debian-lts-announce/2021/06/msg00019.html","name":"https://lists.debian.org/debian-lts-announce/2021/06/msg00019.html","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Mailing List","Third Party Advisory"],"title":"[SECURITY] [DLA 2690-1] linux-4.19 security update","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63","name":"https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"],"title":"Security Advisory 0063 - Arista","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWu","name":"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWu","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"],"title":"Multiple Vulnerabilities in Frame Aggregation and Fragmentation Implementations of 802.11 Specification Affecting Cisco Products: May 2021","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://www.openwall.com/lists/oss-security/2021/05/11/12","name":"http://www.openwall.com/lists/oss-security/2021/05/11/12","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Mailing List","Patch","Third Party Advisory"],"title":"oss-security - various 802.11 security issues - fragattacks.com","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-26147","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-26147","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"n/a","version":"affected n/a","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W1748-1 M12","version":"affected V3.0.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W1748-1 M12","version":"affected V3.0.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W1788-1 M12","version":"affected V3.0.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W1788-2 EEC M12","version":"affected V3.0.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W1788-2 M12","version":"affected V3.0.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W1788-2IA M12","version":"affected V3.0.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W721-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W721-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W721-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W721-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W722-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W722-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W722-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W722-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W722-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W722-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45 (USA)","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W734-1 RJ45 (USA)","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W738-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W738-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W738-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W738-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W748-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W761-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W761-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W761-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W761-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45 (USA)","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W774-1 RJ45 (USA)","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12 EEC (USA)","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W778-1 M12 EEC (USA)","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 SFP","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 SFP","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 SFP","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2 SFP","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2IA RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2IA RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2IA RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W786-2IA RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-1 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 M12 EEC","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 RJ45","version":"affected V6.6.0 custom","platforms":[]},{"source":"ADP","vendor":"Siemens","product":"SCALANCE W788-2 RJ45","version":"affected V6.6.0 custom","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2020","cve_id":"26147","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"linux","cpe5":"linux_kernel","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2020-26147","qid":"159338","title":"Oracle Enterprise Linux Security Update for Unbreakable Enterprise kernel (ELSA-2021-9404)"},{"cve":"CVE-2020-26147","qid":"159339","title":"Oracle Enterprise Linux Security Update for Unbreakable Enterprise kernel-container (ELSA-2021-9406)"},{"cve":"CVE-2020-26147","qid":"159399","title":"Oracle Enterprise Linux Security Update for Unbreakable Enterprise kernel (ELSA-2021-9452)"},{"cve":"CVE-2020-26147","qid":"159400","title":"Oracle Enterprise Linux Security Update for Unbreakable Enterprise kernel-container (ELSA-2021-9453)"},{"cve":"CVE-2020-26147","qid":"159403","title":"Oracle Enterprise Linux Security Update for Unbreakable Enterprise kernel (ELSA-2021-9459)"},{"cve":"CVE-2020-26147","qid":"159492","title":"Oracle Enterprise Linux Security Update for kernel (ELSA-2021-4356)"},{"cve":"CVE-2020-26147","qid":"178679","title":"Debian Security Update for linux-4.19 (DLA 2690-1)"},{"cve":"CVE-2020-26147","qid":"178680","title":"Debian Security Update for linux (DLA 2689-1)"},{"cve":"CVE-2020-26147","qid":"198416","title":"Ubuntu Security Notification for Linux kernel vulnerabilities (USN-4997-1)"},{"cve":"CVE-2020-26147","qid":"198417","title":"Ubuntu Security Notification for Linux kernel vulnerabilities (USN-4999-1)"},{"cve":"CVE-2020-26147","qid":"198418","title":"Ubuntu Security Notification for Linux kernel vulnerabilities (USN-5000-1)"},{"cve":"CVE-2020-26147","qid":"198419","title":"Ubuntu Security Notification for Linux kernel (OEM) vulnerabilities (USN-5001-1)"},{"cve":"CVE-2020-26147","qid":"198425","title":"Ubuntu Security Notification for Linux kernel (KVM) vulnerabilities (USN-5000-2)"},{"cve":"CVE-2020-26147","qid":"198426","title":"Ubuntu Security Notification for Linux kernel (KVM) vulnerabilities (USN-4997-2)"},{"cve":"CVE-2020-26147","qid":"198459","title":"Ubuntu Security Notification for Linux, Linux-aws, Linux-aws-hwe, Linux-azure, Linux-azure-4.15, Linux-gcp, (USN-5018-1)"},{"cve":"CVE-2020-26147","qid":"239816","title":"Red Hat Update for kernel security (RHSA-2021:4356)"},{"cve":"CVE-2020-26147","qid":"239879","title":"Red Hat Update for kernel-rt (RHSA-2021:4140)"},{"cve":"CVE-2020-26147","qid":"352831","title":"Amazon Linux Security Advisory for kernel: ALAC2012-2021-030"},{"cve":"CVE-2020-26147","qid":"352832","title":"Amazon Linux Security Advisory for kmod-sfc: ALAC2012-2021-031"},{"cve":"CVE-2020-26147","qid":"352833","title":"Amazon Linux Security Advisory for kmod-mlx5: ALAC2012-2021-032"},{"cve":"CVE-2020-26147","qid":"353147","title":"Amazon Linux Security Advisory for kernel : ALAS2KERNEL-5.4-2022-004"},{"cve":"CVE-2020-26147","qid":"353158","title":"Amazon Linux Security Advisory for kernel : ALAS2KERNEL-5.10-2022-002"},{"cve":"CVE-2020-26147","qid":"390248","title":"Oracle Managed Virtualization (VM) Server for x86 Security Update for kernel (OVMSA-2021-0035)"},{"cve":"CVE-2020-26147","qid":"591035","title":"Siemens SCALANCE FragAttacks Multiple Vulnerabilities (ICSA-22-104-04) (SSA-913875)"},{"cve":"CVE-2020-26147","qid":"591150","title":"Hitachi ABB Power Grids TropOS Multiple Vulnerabilities (ICSA-21-236-01,9AKK107992A4463)"},{"cve":"CVE-2020-26147","qid":"610373","title":"Google Android Devices October 2021 Security Patch Missing"},{"cve":"CVE-2020-26147","qid":"610383","title":"Google Android November 2021 Security Patch Missing for LGE"},{"cve":"CVE-2020-26147","qid":"671051","title":"EulerOS Security Update for kernel (EulerOS-SA-2021-2663)"},{"cve":"CVE-2020-26147","qid":"671441","title":"EulerOS Security Update for kernel (EulerOS-SA-2022-1366)"},{"cve":"CVE-2020-26147","qid":"671703","title":"EulerOS Security Update for kernel (EulerOS-SA-2022-1735)"},{"cve":"CVE-2020-26147","qid":"690816","title":"Free Berkeley Software Distribution (FreeBSD) Security Update for freebsd-kernel (8d20bd48-a4f3-11ec-90de-1c697aa5a594)"},{"cve":"CVE-2020-26147","qid":"750117","title":"SUSE Enterprise Linux Security Update for the Linux Kernel (SUSE-SU-2021:1891-1)"},{"cve":"CVE-2020-26147","qid":"750118","title":"SUSE Enterprise Linux Security Update for the Linux Kernel (SUSE-SU-2021:1890-1)"},{"cve":"CVE-2020-26147","qid":"750121","title":"SUSE Enterprise Linux Security Update for the Linux Kernel (SUSE-SU-2021:1888-1)"},{"cve":"CVE-2020-26147","qid":"750125","title":"SUSE Enterprise Linux Security Update for the Linux Kernel (SUSE-SU-2021:1887-1)"},{"cve":"CVE-2020-26147","qid":"750126","title":"SUSE Enterprise Linux Security Update for the Linux Kernel (SUSE-SU-2021:1889-1)"},{"cve":"CVE-2020-26147","qid":"750139","title":"SUSE Enterprise Linux Security Update for the Linux Kernel (SUSE-SU-2021:1913-1)"},{"cve":"CVE-2020-26147","qid":"750140","title":"SUSE Enterprise Linux Security Update for the Linux Kernel (SUSE-SU-2021:1912-1)"},{"cve":"CVE-2020-26147","qid":"750171","title":"OpenSUSE Security Update for the Linux Kernel (openSUSE-SU-2021:0843-1)"},{"cve":"CVE-2020-26147","qid":"750650","title":"SUSE Enterprise Linux Security Update for the Linux Kernel (SUSE-SU-2021:1975-1)"},{"cve":"CVE-2020-26147","qid":"750652","title":"SUSE Enterprise Linux Security Update for the Linux Kernel (SUSE-SU-2021:1977-1)"},{"cve":"CVE-2020-26147","qid":"750741","title":"OpenSUSE Security Update for the Linux Kernel (openSUSE-SU-2021:0947-1)"},{"cve":"CVE-2020-26147","qid":"750762","title":"OpenSUSE Security Update for the Linux Kernel (openSUSE-SU-2021:1977-1)"},{"cve":"CVE-2020-26147","qid":"750766","title":"OpenSUSE Security Update for the Linux Kernel (openSUSE-SU-2021:1975-1)"},{"cve":"CVE-2020-26147","qid":"750864","title":"SUSE Enterprise Linux Security Update for the Linux Kernel (SUSE-SU-2021:2421-1)"},{"cve":"CVE-2020-26147","qid":"750880","title":"SUSE Enterprise Linux Security Update for the Linux Kernel (SUSE-SU-2021:2451-1)"},{"cve":"CVE-2020-26147","qid":"940265","title":"AlmaLinux Security Update for kernel (ALSA-2021:4356)"}]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-04T15:49:07.202Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"name":"20210511 Multiple Vulnerabilities in Frame Aggregation and Fragmentation Implementations of 802.11 Specification Affecting Cisco Products: May 2021","tags":["vendor-advisory","x_refsource_CISCO","x_transferred"],"url":"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWu"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.fragattacks.com"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md"},{"name":"[oss-security] 20210511 various 802.11 security issues - fragattacks.com","tags":["mailing-list","x_refsource_MLIST","x_transferred"],"url":"http://www.openwall.com/lists/oss-security/2021/05/11/12"},{"name":"[debian-lts-announce] 20210623 [SECURITY] [DLA 2689-1] linux security update","tags":["mailing-list","x_refsource_MLIST","x_transferred"],"url":"https://lists.debian.org/debian-lts-announce/2021/06/msg00020.html"},{"name":"[debian-lts-announce] 20210623 [SECURITY] [DLA 2690-1] linux-4.19 security update","tags":["mailing-list","x_refsource_MLIST","x_transferred"],"url":"https://lists.debian.org/debian-lts-announce/2021/06/msg00019.html"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63"}],"title":"CVE Program Container"},{"affected":[{"defaultStatus":"unknown","product":"SCALANCE W1748-1 M12","vendor":"Siemens","versions":[{"lessThan":"V3.0.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W1748-1 M12","vendor":"Siemens","versions":[{"lessThan":"V3.0.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W1788-1 M12","vendor":"Siemens","versions":[{"lessThan":"V3.0.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W1788-2 EEC M12","vendor":"Siemens","versions":[{"lessThan":"V3.0.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W1788-2 M12","vendor":"Siemens","versions":[{"lessThan":"V3.0.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W1788-2IA M12","vendor":"Siemens","versions":[{"lessThan":"V3.0.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W721-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W721-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W721-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W721-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W722-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W722-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W722-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W722-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W722-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W722-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45 (USA)","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W734-1 RJ45 (USA)","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W738-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W738-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W738-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W738-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W748-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W761-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W761-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W761-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W761-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45 (USA)","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W774-1 RJ45 (USA)","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12 EEC (USA)","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W778-1 M12 EEC (USA)","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 SFP","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 SFP","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 SFP","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2 SFP","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2IA RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2IA RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2IA RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W786-2IA RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-1 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 M12 EEC","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unknown","product":"SCALANCE W788-2 RJ45","vendor":"Siemens","versions":[{"lessThan":"V6.6.0","status":"affected","version":"0","versionType":"custom"}]}],"providerMetadata":{"dateUpdated":"2026-04-14T09:01:51.571Z","orgId":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","shortName":"siemens-SADP"},"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-913875.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-019200.html"}],"x_adpType":"supplier"}],"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"descriptions":[{"lang":"en","value":"An issue was discovered in the Linux kernel 5.8.9. The WEP, WPA, WPA2, and WPA3 implementations reassemble fragments even though some of them were sent in plaintext. This vulnerability can be abused to inject packets and/or exfiltrate selected fragments when another device sends fragmented frames and the WEP, CCMP, or GCMP data-confidentiality protocol is used."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2021-10-28T14:30:09.000Z","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre"},"references":[{"name":"20210511 Multiple Vulnerabilities in Frame Aggregation and Fragmentation Implementations of 802.11 Specification Affecting Cisco Products: May 2021","tags":["vendor-advisory","x_refsource_CISCO"],"url":"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWu"},{"tags":["x_refsource_MISC"],"url":"https://www.fragattacks.com"},{"tags":["x_refsource_MISC"],"url":"https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md"},{"name":"[oss-security] 20210511 various 802.11 security issues - fragattacks.com","tags":["mailing-list","x_refsource_MLIST"],"url":"http://www.openwall.com/lists/oss-security/2021/05/11/12"},{"name":"[debian-lts-announce] 20210623 [SECURITY] [DLA 2689-1] linux security update","tags":["mailing-list","x_refsource_MLIST"],"url":"https://lists.debian.org/debian-lts-announce/2021/06/msg00020.html"},{"name":"[debian-lts-announce] 20210623 [SECURITY] [DLA 2690-1] linux-4.19 security update","tags":["mailing-list","x_refsource_MLIST"],"url":"https://lists.debian.org/debian-lts-announce/2021/06/msg00019.html"},{"tags":["x_refsource_CONFIRM"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf"},{"tags":["x_refsource_MISC"],"url":"https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2020-26147","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An issue was discovered in the Linux kernel 5.8.9. The WEP, WPA, WPA2, and WPA3 implementations reassemble fragments even though some of them were sent in plaintext. This vulnerability can be abused to inject packets and/or exfiltrate selected fragments when another device sends fragmented frames and the WEP, CCMP, or GCMP data-confidentiality protocol is used."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"20210511 Multiple Vulnerabilities in Frame Aggregation and Fragmentation Implementations of 802.11 Specification Affecting Cisco Products: May 2021","refsource":"CISCO","url":"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWu"},{"name":"https://www.fragattacks.com","refsource":"MISC","url":"https://www.fragattacks.com"},{"name":"https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md","refsource":"MISC","url":"https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md"},{"name":"[oss-security] 20210511 various 802.11 security issues - fragattacks.com","refsource":"MLIST","url":"http://www.openwall.com/lists/oss-security/2021/05/11/12"},{"name":"[debian-lts-announce] 20210623 [SECURITY] [DLA 2689-1] linux security update","refsource":"MLIST","url":"https://lists.debian.org/debian-lts-announce/2021/06/msg00020.html"},{"name":"[debian-lts-announce] 20210623 [SECURITY] [DLA 2690-1] linux-4.19 security update","refsource":"MLIST","url":"https://lists.debian.org/debian-lts-announce/2021/06/msg00019.html"},{"name":"https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf","refsource":"CONFIRM","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf"},{"name":"https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63","refsource":"MISC","url":"https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63"}]}}}},"cveMetadata":{"assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","assignerShortName":"mitre","cveId":"CVE-2020-26147","datePublished":"2021-05-11T19:40:19.000Z","dateReserved":"2020-09-29T00:00:00.000Z","dateUpdated":"2026-04-14T09:01:51.571Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2021-05-11 20:15:08","lastModifiedDate":"2026-04-14 10:16:18","problem_types":["NVD-CWE-Other","n/a"],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:N","baseScore":5.4,"baseSeverity":"MEDIUM","attackVector":"ADJACENT_NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":1.2,"impactScore":4.2}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:A/AC:H/Au:N/C:P/I:P/A:N","baseScore":3.2,"accessVector":"ADJACENT_NETWORK","accessComplexity":"HIGH","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"LOW","exploitabilityScore":3.2,"impactScore":4.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*","versionStartIncluding":"4.4","versionEndExcluding":"4.4.271","matchCriteriaId":"C2C083CF-3D4D-4AF0-8461-835F6AC264CC"},{"vulnerable":true,"criteria":"cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*","versionStartIncluding":"4.9","versionEndExcluding":"4.9.271","matchCriteriaId":"11580478-2F79-45B8-9BC0-FEF28259A4F5"},{"vulnerable":true,"criteria":"cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*","versionStartIncluding":"4.14","versionEndExcluding":"4.14.235","matchCriteriaId":"970E3D3C-8829-4599-95A7-AC63136CE48E"},{"vulnerable":true,"criteria":"cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*","versionStartIncluding":"4.19","versionEndExcluding":"4.19.193","matchCriteriaId":"FC7D3563-5878-403A-9BB7-6C44E6FE10A0"},{"vulnerable":true,"criteria":"cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*","versionStartIncluding":"5.4","versionEndExcluding":"5.4.124","matchCriteriaId":"01D49B11-5E8A-427F-B9BE-8A5174DEDD65"},{"vulnerable":true,"criteria":"cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*","versionStartIncluding":"5.10","versionEndExcluding":"5.10.42","matchCriteriaId":"B39B1E70-2AF7-4482-9ADF-45A1C04A4BC3"},{"vulnerable":true,"criteria":"cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*","versionStartIncluding":"5.12","versionEndExcluding":"5.12.9","matchCriteriaId":"3B1CFA77-6B5E-430C-AC49-3B3508F2D903"}]}]},{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*","matchCriteriaId":"DEECE5FC-CACF-4496-A3E7-164736409252"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:arista:c-75_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"AD2A3CCF-E8B5-4E7F-BCE7-DB70E8E72B4B"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:arista:c-75:-:*:*:*:*:*:*:*","matchCriteriaId":"8EE26D5A-486B-48F3-9C1C-4EE3FD8F0234"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:arista:o-90_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"0B9860B5-6CC7-4F29-9514-A469AF6B28F1"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:arista:o-90:-:*:*:*:*:*:*:*","matchCriteriaId":"41F9E4B2-63FC-4F53-9C12-7478B7B6AD48"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:arista:c-65_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"8C890ABE-5D64-4D7F-A67B-BC026649E0B3"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:arista:c-65:-:*:*:*:*:*:*:*","matchCriteriaId":"6B617EA3-E69E-43CA-99D4-86A408C55C90"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:arista:w-68_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"1C1EF830-C210-48DB-A3F8-FC706AC5F3C7"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:arista:w-68:-:*:*:*:*:*:*:*","matchCriteriaId":"9F03BB48-C89A-41F6-99DE-12FF95DCD9F2"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_w700_ieee_802.11n_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"F05D6764-79B4-4787-B2D2-E685910453C3"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_w700_ieee_802.11n:-:*:*:*:*:*:*:*","matchCriteriaId":"880644DA-9280-4498-AD72-5CBD59CC8142"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_w1700_ieee_802.11ac_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"180881A1-AA78-411E-B508-D4C0D7084E28"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_w1700_ieee_802.11ac:-:*:*:*:*:*:*:*","matchCriteriaId":"55CA7B83-9295-451A-9B78-832761A6BA79"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"26147","Ordinal":"1","Title":"CVE-2020-26147","CVE":"CVE-2020-26147","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"26147","Ordinal":"1","NoteData":"An issue was discovered in the Linux kernel 5.8.9. The WEP, WPA, WPA2, and WPA3 implementations reassemble fragments even though some of them were sent in plaintext. This vulnerability can be abused to inject packets and/or exfiltrate selected fragments when another device sends fragmented frames and the WEP, CCMP, or GCMP data-confidentiality protocol is used.","Type":"Description","Title":"CVE-2020-26147"},{"CveYear":"2020","CveId":"26147","Ordinal":"2","NoteData":"2021-05-11","Type":"Other","Title":"Published"},{"CveYear":"2020","CveId":"26147","Ordinal":"3","NoteData":"2021-10-28","Type":"Other","Title":"Modified"}]}}}