{"api_version":"1","generated_at":"2026-05-13T06:36:52+00:00","cve":"CVE-2020-28210","urls":{"html":"https://cve.report/CVE-2020-28210","api":"https://cve.report/api/cve/CVE-2020-28210.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-28210","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-28210"},"summary":{"title":"CVE-2020-28210","description":"A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability exists in EcoStruxure Building Operation WebStation V2.0 - V3.1 that could cause an attacker to inject HTML and JavaScript code into the user's browser.","state":"PUBLIC","assigner":"cybersecurity@schneider-electric.com","published_at":"2020-11-19 21:15:00","updated_at":"2022-01-31 19:33:00"},"problem_types":["CWE-79"],"metrics":[],"references":[{"url":"https://www.se.com/ww/en/download/document/SEVD-2020-315-04/","name":"https://www.se.com/ww/en/download/document/SEVD-2020-315-04/","refsource":"MISC","tags":["Vendor Advisory"],"title":"Security Notification - EcoStruxure™ Building Operation (EBO) | Schneider Electric","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-28210","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-28210","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2020","cve_id":"28210","vulnerable":"1","versionEndIncluding":"3.1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"ecostruxure_building_operation","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"28210","vulnerable":"1","versionEndIncluding":"3.1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"se","cpe5":"ecostruxure_building_operation","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2020-28210","ASSIGNER":"cybersecurity@schneider-electric.com","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"EcoStruxure Building Operation WebStation V2.0 - V3.1","version":{"version_data":[{"version_value":"EcoStruxure Building Operation WebStation V2.0 - V3.1"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-79: Improper Neutralization of Input During Web Page Generation (Cross-siteScripting Stored)"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://www.se.com/ww/en/download/document/SEVD-2020-315-04/","url":"https://www.se.com/ww/en/download/document/SEVD-2020-315-04/"}]},"description":{"description_data":[{"lang":"eng","value":"A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability exists in EcoStruxure Building Operation WebStation V2.0 - V3.1 that could cause an attacker to inject HTML and JavaScript code into the user's browser."}]}},"nvd":{"publishedDate":"2020-11-19 21:15:00","lastModifiedDate":"2022-01-31 19:33:00","problem_types":["CWE-79"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE","baseScore":6.1,"baseSeverity":"MEDIUM"},"exploitabilityScore":2.8,"impactScore":2.7},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:N/I:P/A:N","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE","baseScore":4.3},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:ecostruxure_building_operation:*:*:*:*:*:*:*:*","versionStartIncluding":"2.0","versionEndIncluding":"3.1","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"28210","Ordinal":"189946","Title":"CVE-2020-28210","CVE":"CVE-2020-28210","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"28210","Ordinal":"1","NoteData":"A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability exists in EcoStruxure Building Operation WebStation V2.0 - V3.1 that could cause an attacker to inject HTML and JavaScript code into the user's browser.","Type":"Description","Title":null},{"CveYear":"2020","CveId":"28210","Ordinal":"2","NoteData":"2020-11-19","Type":"Other","Title":"Published"},{"CveYear":"2020","CveId":"28210","Ordinal":"3","NoteData":"2020-11-19","Type":"Other","Title":"Modified"}]}}}