{"api_version":"1","generated_at":"2026-05-04T10:23:33+00:00","cve":"CVE-2020-29189","urls":{"html":"https://cve.report/CVE-2020-29189","api":"https://cve.report/api/cve/CVE-2020-29189.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-29189","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-29189"},"summary":{"title":"CVE-2020-29189","description":"Incorrect Access Control vulnerability in TerraMaster TOS <= 4.2.06 allows remote authenticated attackers to bypass read-only restriction and obtain full access to any folder within the NAS","state":"PUBLIC","assigner":"cve@mitre.org","published_at":"2020-12-24 15:15:00","updated_at":"2021-07-21 11:39:00"},"problem_types":["NVD-CWE-noinfo"],"metrics":[],"references":[{"url":"https://www.ihteam.net/advisory/terramaster-tos-multiple-vulnerabilities/","name":"https://www.ihteam.net/advisory/terramaster-tos-multiple-vulnerabilities/","refsource":"MISC","tags":["Exploit","Third Party Advisory"],"title":"TerraMaster TOS Multiple Vulnerabilities - IHTeam Security Blog","mime":"text/html","httpstatus":"200","archivestatus":"403"},{"url":"http://terramaster.com","name":"http://terramaster.com","refsource":"MISC","tags":["Vendor Advisory"],"title":"","mime":"","httpstatus":"-1","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-29189","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-29189","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2020","cve_id":"29189","vulnerable":"1","versionEndIncluding":"4.2.06","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"terra-master","cpe5":"tos","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2020-29189","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Incorrect Access Control vulnerability in TerraMaster TOS <= 4.2.06 allows remote authenticated attackers to bypass read-only restriction and obtain full access to any folder within the NAS"}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"url":"http://terramaster.com","refsource":"MISC","name":"http://terramaster.com"},{"refsource":"MISC","name":"https://www.ihteam.net/advisory/terramaster-tos-multiple-vulnerabilities/","url":"https://www.ihteam.net/advisory/terramaster-tos-multiple-vulnerabilities/"}]}},"nvd":{"publishedDate":"2020-12-24 15:15:00","lastModifiedDate":"2021-07-21 11:39:00","problem_types":["NVD-CWE-noinfo"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"NONE","baseScore":8.1,"baseSeverity":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.2},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:P/A:N","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"NONE","baseScore":5.5},"severity":"MEDIUM","exploitabilityScore":8,"impactScore":4.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:terra-master:tos:*:*:*:*:*:*:*:*","versionEndIncluding":"4.2.06","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"29189","Ordinal":"192254","Title":"CVE-2020-29189","CVE":"CVE-2020-29189","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"29189","Ordinal":"1","NoteData":"Incorrect Access Control vulnerability in TerraMaster TOS <= 4.2.06 allows remote authenticated attackers to bypass read-only restriction and obtain full access to any folder within the NAS","Type":"Description","Title":null},{"CveYear":"2020","CveId":"29189","Ordinal":"2","NoteData":"2020-12-24","Type":"Other","Title":"Published"},{"CveYear":"2020","CveId":"29189","Ordinal":"3","NoteData":"2020-12-24","Type":"Other","Title":"Modified"}]}}}