{"api_version":"1","generated_at":"2026-06-05T15:09:02+00:00","cve":"CVE-2020-5725","urls":{"html":"https://cve.report/CVE-2020-5725","api":"https://cve.report/api/cve/CVE-2020-5725.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-5725","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-5725"},"summary":{"title":"CVE-2020-5725","description":"The Grandstream UCM6200 series before 1.0.20.22 is vulnerable to an SQL injection via the HTTP server's websockify endpoint. A remote unauthenticated attacker can invoke the login action with a crafted username and, through the use of timing attacks, can discover user passwords.","state":"PUBLIC","assigner":"vulnreport@tenable.com","published_at":"2020-03-30 20:15:00","updated_at":"2020-03-31 17:15:00"},"problem_types":["CWE-89"],"metrics":[],"references":[{"url":"https://www.tenable.com/security/research/tra-2020-17","name":"https://www.tenable.com/security/research/tra-2020-17","refsource":"CONFIRM","tags":["Exploit","Third Party Advisory"],"title":"Grandstream UCM62xx Multiple SQL Injections - Research Advisory | Tenable®","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"http://packetstormsecurity.com/files/156976/Grandstream-UCM6200-Series-WebSocket-1.0.20.20-SQL-Injection.html","name":"http://packetstormsecurity.com/files/156976/Grandstream-UCM6200-Series-WebSocket-1.0.20.20-SQL-Injection.html","refsource":"MISC","tags":[],"title":"Grandstream UCM6200 Series WebSocket 1.0.20.20 SQL Injection ≈ Packet Storm","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-5725","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-5725","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2020","cve_id":"5725","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"grandstream","cpe5":"ucm6202","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"5725","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"grandstream","cpe5":"ucm6202","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"5725","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"grandstream","cpe5":"ucm6202_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"5725","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"grandstream","cpe5":"ucm6202_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"5725","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"grandstream","cpe5":"ucm6204","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"5725","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"grandstream","cpe5":"ucm6204","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"5725","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"grandstream","cpe5":"ucm6204_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"5725","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"grandstream","cpe5":"ucm6204_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"5725","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"grandstream","cpe5":"ucm6208","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"5725","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"grandstream","cpe5":"ucm6208","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"5725","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"grandstream","cpe5":"ucm6208_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"5725","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"grandstream","cpe5":"ucm6208_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2020-5725","ASSIGNER":"vulnreport@tenable.com","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"Grandstream UCM6200 series","version":{"version_data":[{"version_value":"1.0.20.20 and below"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"SQL Injection (CWE-89)"}]}]},"references":{"reference_data":[{"refsource":"CONFIRM","name":"https://www.tenable.com/security/research/tra-2020-17","url":"https://www.tenable.com/security/research/tra-2020-17"},{"refsource":"MISC","name":"http://packetstormsecurity.com/files/156976/Grandstream-UCM6200-Series-WebSocket-1.0.20.20-SQL-Injection.html","url":"http://packetstormsecurity.com/files/156976/Grandstream-UCM6200-Series-WebSocket-1.0.20.20-SQL-Injection.html"}]},"description":{"description_data":[{"lang":"eng","value":"The Grandstream UCM6200 series before 1.0.20.22 is vulnerable to an SQL injection via the HTTP server's websockify endpoint. A remote unauthenticated attacker can invoke the login action with a crafted username and, through the use of timing attacks, can discover user passwords."}]}},"nvd":{"publishedDate":"2020-03-30 20:15:00","lastModifiedDate":"2020-03-31 17:15:00","problem_types":["CWE-89"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":5.9,"baseSeverity":"MEDIUM"},"exploitabilityScore":2.2,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:N/A:N","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":4.3},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:grandstream:ucm6202_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.20.22","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:grandstream:ucm6202:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:grandstream:ucm6204_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.20.22","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:grandstream:ucm6204:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:grandstream:ucm6208_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.20.22","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:grandstream:ucm6208:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"5725","Ordinal":"165971","Title":"CVE-2020-5725","CVE":"CVE-2020-5725","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"5725","Ordinal":"1","NoteData":"The Grandstream UCM6200 series before 1.0.20.22 is vulnerable to an SQL injection via the HTTP server's websockify endpoint. A remote unauthenticated attacker can invoke the login action with a crafted username and, through the use of timing attacks, can discover user passwords.","Type":"Description","Title":null},{"CveYear":"2020","CveId":"5725","Ordinal":"2","NoteData":"2020-03-30","Type":"Other","Title":"Published"},{"CveYear":"2020","CveId":"5725","Ordinal":"3","NoteData":"2020-03-31","Type":"Other","Title":"Modified"}]}}}