{"api_version":"1","generated_at":"2026-04-22T23:21:53+00:00","cve":"CVE-2020-6994","urls":{"html":"https://cve.report/CVE-2020-6994","api":"https://cve.report/api/cve/CVE-2020-6994.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-6994","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-6994"},"summary":{"title":"CVE-2020-6994","description":"A buffer overflow vulnerability was found in some devices of Hirschmann Automation and Control HiOS and HiSecOS. The vulnerability is due to improper parsing of URL arguments. An attacker could exploit this vulnerability by specially crafting HTTP requests to overflow an internal buffer. The following devices using HiOS Version 07.0.02 and lower are affected: RSP, RSPE, RSPS, RSPL, MSP, EES, EES, EESX, GRS, OS, RED. The following devices using HiSecOS Version 03.2.00 and lower are affected: EAGLE20/30.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2020-04-03 19:15:00","updated_at":"2021-06-17 17:22:00"},"problem_types":["CWE-120"],"metrics":[],"references":[{"url":"https://www.us-cert.gov/ics/advisories/icsa-20-091-01","name":"https://www.us-cert.gov/ics/advisories/icsa-20-091-01","refsource":"MISC","tags":["Mitigation","Third Party Advisory","US Government Resource"],"title":"Hirschmann Automation and Control HiOS and HiSecOS Products | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-6994","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-6994","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2020","cve_id":"6994","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"belden","cpe5":"hirschmann_eagle20","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"belden","cpe5":"hirschmann_eagle30","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"belden","cpe5":"hirschmann_embedded_ethernet_switch","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"belden","cpe5":"hirschmann_embedded_ethernet_switch_extended","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"belden","cpe5":"hirschmann_greyhound_swtich","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"1","versionEndIncluding":"07.0.02","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"belden","cpe5":"hirschmann_hios","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"1","versionEndIncluding":"03.2.00","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"belden","cpe5":"hirschmann_hisecos","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"belden","cpe5":"hirschmann_mice_switch_power","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"belden","cpe5":"hirschmann_octopus","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"belden","cpe5":"hirschmann_prp_redbox","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"belden","cpe5":"hirschmann_rail_switch_power","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"belden","cpe5":"hirschmann_rail_switch_power_enhanced","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"belden","cpe5":"hirschmann_rail_switch_power_lite","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"belden","cpe5":"hirschmann_rail_switch_power_smart","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hirschmann","cpe5":"eagle20","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hirschmann","cpe5":"eagle20","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hirschmann","cpe5":"eagle30","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hirschmann","cpe5":"eagle30","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hirschmann","cpe5":"embedded_ethernet_switch","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hirschmann","cpe5":"embedded_ethernet_switch","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hirschmann","cpe5":"embedded_ethernet_switch_extended","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hirschmann","cpe5":"embedded_ethernet_switch_extended","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hirschmann","cpe5":"greyhound_swtich","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hirschmann","cpe5":"greyhound_swtich","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"1","versionEndIncluding":"07.0.02","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hirschmann","cpe5":"hios","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"1","versionEndIncluding":"03.2.00","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hirschmann","cpe5":"hisecos","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hirschmann","cpe5":"mice_switch_power","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hirschmann","cpe5":"mice_switch_power","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hirschmann","cpe5":"octopus","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hirschmann","cpe5":"octopus","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hirschmann","cpe5":"prp_redbox","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hirschmann","cpe5":"prp_redbox","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hirschmann","cpe5":"rail_switch_power","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hirschmann","cpe5":"rail_switch_power","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hirschmann","cpe5":"rail_switch_power_enhanced","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hirschmann","cpe5":"rail_switch_power_enhanced","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hirschmann","cpe5":"rail_switch_power_lite","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hirschmann","cpe5":"rail_switch_power_lite","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hirschmann","cpe5":"rail_switch_power_smart","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"6994","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hirschmann","cpe5":"rail_switch_power_smart","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2020-6994","qid":"591151","title":"Hitachi Energy AFS660/AFS665 Vulnerability (ICSA-22-270-01,8DBD000122)"},{"cve":"CVE-2020-6994","qid":"591366","title":"Hitachi Energy AFF660/665 Series Stack-based Buffer Overflow Vulnerability (ICSA-22-263-02, 8DBD000122)"}]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2020-6994","ASSIGNER":"ics-cert@hq.dhs.gov","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Hirschmann Automation and Control GmbH, a division of Belden Inc.","product":{"product_data":[{"product_name":"HiOS for the following devices RSP, RSPE, RSPS, RSPL, MSP, EES, EES, EESX, GRS, OS, RED","version":{"version_data":[{"version_value":"07.0.02 and lower"}]}},{"product_name":"HiSecOS for device EAGLE20/30","version":{"version_data":[{"version_value":"03.2.00 and lower"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"BUFFER COPY WITHOUT CHECKING SIZE OF INPUT ('CLASSIC BUFFER OVERFLOW') CWE-12"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://www.us-cert.gov/ics/advisories/icsa-20-091-01","url":"https://www.us-cert.gov/ics/advisories/icsa-20-091-01"}]},"description":{"description_data":[{"lang":"eng","value":"A buffer overflow vulnerability was found in some devices of Hirschmann Automation and Control HiOS and HiSecOS. The vulnerability is due to improper parsing of URL arguments. An attacker could exploit this vulnerability by specially crafting HTTP requests to overflow an internal buffer. The following devices using HiOS Version 07.0.02 and lower are affected: RSP, RSPE, RSPS, RSPL, MSP, EES, EES, EESX, GRS, OS, RED. The following devices using HiSecOS Version 03.2.00 and lower are affected: EAGLE20/30."}]}},"nvd":{"publishedDate":"2020-04-03 19:15:00","lastModifiedDate":"2021-06-17 17:22:00","problem_types":["CWE-120"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL"},"exploitabilityScore":3.9,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":7.5},"severity":"HIGH","exploitabilityScore":10,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:belden:hirschmann_hios:*:*:*:*:*:*:*:*","versionEndIncluding":"07.0.02","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:belden:hirschmann_embedded_ethernet_switch:-:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:belden:hirschmann_embedded_ethernet_switch_extended:-:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:belden:hirschmann_greyhound_swtich:-:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:belden:hirschmann_mice_switch_power:-:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:belden:hirschmann_octopus:-:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:belden:hirschmann_prp_redbox:-:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:belden:hirschmann_rail_switch_power:-:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:belden:hirschmann_rail_switch_power_enhanced:-:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:belden:hirschmann_rail_switch_power_lite:-:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:belden:hirschmann_rail_switch_power_smart:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:belden:hirschmann_hisecos:*:*:*:*:*:*:*:*","versionEndIncluding":"03.2.00","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:belden:hirschmann_eagle20:-:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:belden:hirschmann_eagle30:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"6994","Ordinal":"167265","Title":"CVE-2020-6994","CVE":"CVE-2020-6994","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"6994","Ordinal":"1","NoteData":"A buffer overflow vulnerability was found in some devices of Hirschmann Automation and Control HiOS and HiSecOS. The vulnerability is due to improper parsing of URL arguments. An attacker could exploit this vulnerability by specially crafting HTTP requests to overflow an internal buffer. The following devices using HiOS Version 07.0.02 and lower are affected: RSP, RSPE, RSPS, RSPL, MSP, EES, EES, EESX, GRS, OS, RED. The following devices using HiSecOS Version 03.2.00 and lower are affected: EAGLE20/30.","Type":"Description","Title":null},{"CveYear":"2020","CveId":"6994","Ordinal":"2","NoteData":"2020-04-03","Type":"Other","Title":"Published"},{"CveYear":"2020","CveId":"6994","Ordinal":"3","NoteData":"2020-04-03","Type":"Other","Title":"Modified"}]}}}