{"api_version":"1","generated_at":"2026-07-23T10:04:48+00:00","cve":"CVE-2020-7478","urls":{"html":"https://cve.report/CVE-2020-7478","api":"https://cve.report/api/cve/CVE-2020-7478.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-7478","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-7478"},"summary":{"title":"CVE-2020-7478","description":"A CWE-22: Improper Limitation of a Pathname to a Restricted Directory exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a remote unauthenticated attacker to read arbitrary files from the IGSS server PC on an unrestricted or shared network when the IGSS Update Service is enabled.","state":"PUBLIC","assigner":"cybersecurity@schneider-electric.com","published_at":"2020-03-23 20:15:00","updated_at":"2022-10-07 01:58:00"},"problem_types":["CWE-22"],"metrics":[],"references":[{"url":"https://www.se.com/ww/en/download/document/SEVD-2020-070-01/","name":"https://www.se.com/ww/en/download/document/SEVD-2020-070-01/","refsource":"MISC","tags":["Vendor Advisory"],"title":"Security Notification - IGSS (Interactive Graphical SCADA System) | Schneider Electric","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-20-371/","name":"https://www.zerodayinitiative.com/advisories/ZDI-20-371/","refsource":"MISC","tags":[],"title":"ZDI-20-371 | Zero Day Initiative","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-7478","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-7478","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2020","cve_id":"7478","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"interactive_graphical_scada_system","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"7478","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"interactive_graphical_scada_system","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2020-7478","ASSIGNER":"cybersecurity@schneider-electric.com","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"IGSS (Interactive Graphical SCADA System) (IGSS Version prior to 14.0.0.20009)","version":{"version_data":[{"version_value":"IGSS (Interactive Graphical SCADA System) (Versions 14 and prior using the service: IGSSupdate)"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-22: Improper Limitation of a Pathname to a Restricted Directory"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://www.se.com/ww/en/download/document/SEVD-2020-070-01/","url":"https://www.se.com/ww/en/download/document/SEVD-2020-070-01/"},{"refsource":"MISC","name":"https://www.zerodayinitiative.com/advisories/ZDI-20-371/","url":"https://www.zerodayinitiative.com/advisories/ZDI-20-371/"}]},"description":{"description_data":[{"lang":"eng","value":"A CWE-22: Improper Limitation of a Pathname to a Restricted Directory exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a remote unauthenticated attacker to read arbitrary files from the IGSS server PC on an unrestricted or shared network when the IGSS Update Service is enabled."}]}},"nvd":{"publishedDate":"2020-03-23 20:15:00","lastModifiedDate":"2022-10-07 01:58:00","problem_types":["CWE-22"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":7.5,"baseSeverity":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":5},"severity":"MEDIUM","exploitabilityScore":10,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*","versionStartIncluding":"14.0","versionEndExcluding":"14.0.0.20009","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"7478","Ordinal":"167757","Title":"CVE-2020-7478","CVE":"CVE-2020-7478","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"7478","Ordinal":"1","NoteData":"A CWE-22: Improper Limitation of a Pathname to a Restricted Directory exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a remote unauthenticated attacker to read arbitrary files from the IGSS server PC on an unrestricted or shared network when the IGSS Update Service is enabled.","Type":"Description","Title":null},{"CveYear":"2020","CveId":"7478","Ordinal":"2","NoteData":"2020-03-23","Type":"Other","Title":"Published"},{"CveYear":"2020","CveId":"7478","Ordinal":"3","NoteData":"2020-04-03","Type":"Other","Title":"Modified"}]}}}