{"api_version":"1","generated_at":"2026-07-23T11:17:39+00:00","cve":"CVE-2020-7515","urls":{"html":"https://cve.report/CVE-2020-7515","api":"https://cve.report/api/cve/CVE-2020-7515.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-7515","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-7515"},"summary":{"title":"CVE-2020-7515","description":"A CWE-321: Use of hard-coded cryptographic key stored in cleartext vulnerability exists in Easergy Builder V1.4.7.2 and prior which could allow an attacker to decrypt a password.","state":"PUBLIC","assigner":"cybersecurity@schneider-electric.com","published_at":"2020-07-23 21:15:00","updated_at":"2021-12-10 21:28:00"},"problem_types":["CWE-798"],"metrics":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2020-161-05","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2020-161-05","refsource":"MISC","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://www.se.com/ww/en/download/document/SEVD-2020-161-05","name":"https://www.se.com/ww/en/download/document/SEVD-2020-161-05","refsource":"MISC","tags":["Vendor Advisory"],"title":"Security Notification - Easergy Builder | Schneider Electric","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-7515","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-7515","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2020","cve_id":"7515","vulnerable":"1","versionEndIncluding":"1.4.7.2","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"easergy_builder","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2020-7515","qid":"591045","title":"Schneider Electric Easergy Builder Multiple Vulnerabilities (SEVD-2020-161-05)"}]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2020-7515","ASSIGNER":"cybersecurity@schneider-electric.com","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"Easergy Builder V1.4.7.2 and prior","version":{"version_data":[{"version_value":"Easergy Builder V1.4.7.2 and prior"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-798: Use of Hard-coded Credentials"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2020-161-05","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2020-161-05"}]},"description":{"description_data":[{"lang":"eng","value":"A CWE-321: Use of hard-coded cryptographic key stored in cleartext vulnerability exists in Easergy Builder V1.4.7.2 and prior which could allow an attacker to decrypt a password."}]}},"nvd":{"publishedDate":"2020-07-23 21:15:00","lastModifiedDate":"2021-12-10 21:28:00","problem_types":["CWE-798"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:P/I:N/A:N","accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":2.1},"severity":"LOW","exploitabilityScore":3.9,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:easergy_builder:*:*:*:*:*:*:*:*","versionEndIncluding":"1.4.7.2","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"7515","Ordinal":"167794","Title":"CVE-2020-7515","CVE":"CVE-2020-7515","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"7515","Ordinal":"1","NoteData":"A CWE-321: Use of hard-coded cryptographic key stored in cleartext vulnerability exists in Easergy Builder V1.4.7.2 and prior which could allow an attacker to decrypt a password.","Type":"Description","Title":null},{"CveYear":"2020","CveId":"7515","Ordinal":"2","NoteData":"2020-07-23","Type":"Other","Title":"Published"},{"CveYear":"2020","CveId":"7515","Ordinal":"3","NoteData":"2021-06-11","Type":"Other","Title":"Modified"}]}}}