{"api_version":"1","generated_at":"2026-07-23T13:15:41+00:00","cve":"CVE-2020-7529","urls":{"html":"https://cve.report/CVE-2020-7529","api":"https://cve.report/api/cve/CVE-2020-7529.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-7529","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-7529"},"summary":{"title":"CVE-2020-7529","description":"A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Transversal') vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows an attacker to place content in any unprotected folder on the target system using a crafted .RCZ file.","state":"PUBLIC","assigner":"cybersecurity@schneider-electric.com","published_at":"2020-09-16 16:15:00","updated_at":"2020-09-21 19:32:00"},"problem_types":["CWE-22"],"metrics":[],"references":[{"url":"https://www.se.com/ww/en/download/document/SEVD-2020-252-01/","name":"https://www.se.com/ww/en/download/document/SEVD-2020-252-01/","refsource":"MISC","tags":["Vendor Advisory"],"title":"Security Notification - SCADAPack 7x Remote Connect and SCADAPack x70 Security Administrator (V1.2) | Schneider Electric","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-7529","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-7529","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2020","cve_id":"7529","vulnerable":"1","versionEndIncluding":"3.6.3.574","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"scadapack_7x_remote_connect","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2020-7529","ASSIGNER":"cybersecurity@schneider-electric.com","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"SCADAPack 7x Remote Connect V3.6.3.574 and prior.","version":{"version_data":[{"version_value":"SCADAPack 7x Remote Connect V3.6.3.574 and prior."}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Transversal') "}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://www.se.com/ww/en/download/document/SEVD-2020-252-01/","url":"https://www.se.com/ww/en/download/document/SEVD-2020-252-01/"}]},"description":{"description_data":[{"lang":"eng","value":"A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Transversal') vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows an attacker to place content in any unprotected folder on the target system using a crafted .RCZ file."}]}},"nvd":{"publishedDate":"2020-09-16 16:15:00","lastModifiedDate":"2020-09-21 19:32:00","problem_types":["CWE-22"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"HIGH","availabilityImpact":"NONE","baseScore":5.5,"baseSeverity":"MEDIUM"},"exploitabilityScore":1.8,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:N/I:P/A:N","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE","baseScore":4.3},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:scadapack_7x_remote_connect:*:*:*:*:*:*:*:*","versionEndIncluding":"3.6.3.574","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"7529","Ordinal":"167808","Title":"CVE-2020-7529","CVE":"CVE-2020-7529","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"7529","Ordinal":"1","NoteData":"A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Transversal') vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows an attacker to place content in any unprotected folder on the target system using a crafted .RCZ file.","Type":"Description","Title":null},{"CveYear":"2020","CveId":"7529","Ordinal":"2","NoteData":"2020-09-16","Type":"Other","Title":"Published"},{"CveYear":"2020","CveId":"7529","Ordinal":"3","NoteData":"2020-09-16","Type":"Other","Title":"Modified"}]}}}