{"api_version":"1","generated_at":"2026-07-23T09:38:13+00:00","cve":"CVE-2020-7577","urls":{"html":"https://cve.report/CVE-2020-7577","api":"https://cve.report/api/cve/CVE-2020-7577.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-7577","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-7577"},"summary":{"title":"CVE-2020-7577","description":"A vulnerability has been identified in Camstar Enterprise Platform (All versions), Opcenter Execution Core (All versions < V8.2). Through the use of several vulnerable fields of the application, an authenticated user could perform an SQL Injection attack by passing a modified SQL query downstream to the back-end server. The exploit of this vulnerability could be used to read, and potentially modify application data to which the user has access to.","state":"PUBLIC","assigner":"productcert@siemens.com","published_at":"2020-07-14 14:15:00","updated_at":"2020-07-17 18:03:00"},"problem_types":["CWE-89"],"metrics":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-604937.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-604937.pdf","refsource":"MISC","tags":["Vendor Advisory"],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-7577","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-7577","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2020","cve_id":"7577","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"opcenter_execution_core","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"7577","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"opcenter_execution_core","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2020-7577","STATE":"PUBLIC"},"data_format":"MITRE","data_version":"4.0","data_type":"CVE","affects":{"vendor":{"vendor_data":[{"vendor_name":"Siemens","product":{"product_data":[{"product_name":"Camstar Enterprise Platform","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"Opcenter Execution Core","version":{"version_data":[{"version_value":"All versions < V8.2"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')"}]}]},"description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in Camstar Enterprise Platform (All versions), Opcenter Execution Core (All versions < V8.2). Through the use of several vulnerable fields of the application, an authenticated user could perform an SQL Injection attack by passing a modified SQL query downstream to the back-end server. The exploit of this vulnerability could be used to read, and potentially modify application data to which the user has access to."}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-604937.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-604937.pdf"}]}},"nvd":{"publishedDate":"2020-07-14 14:15:00","lastModifiedDate":"2020-07-17 18:03:00","problem_types":["CWE-89"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"NONE","baseScore":8.1,"baseSeverity":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.2},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:P/A:N","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"NONE","baseScore":5.5},"severity":"MEDIUM","exploitabilityScore":8,"impactScore":4.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:opcenter_execution_core:*:*:*:*:*:*:*:*","versionEndExcluding":"8.2","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"7577","Ordinal":"167856","Title":"CVE-2020-7577","CVE":"CVE-2020-7577","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"7577","Ordinal":"1","NoteData":"A vulnerability has been identified in Camstar Enterprise Platform (All versions), Opcenter Execution Core (All versions < V8.2). Through the use of several vulnerable fields of the application, an authenticated user could perform an SQL Injection attack by passing a modified SQL query downstream to the back-end server. The exploit of this vulnerability could be used to read, and potentially modify application data to which the user has access to.","Type":"Description","Title":null},{"CveYear":"2020","CveId":"7577","Ordinal":"2","NoteData":"2020-07-14","Type":"Other","Title":"Published"},{"CveYear":"2020","CveId":"7577","Ordinal":"3","NoteData":"2021-01-12","Type":"Other","Title":"Modified"}]}}}