{"api_version":"1","generated_at":"2026-07-23T23:23:13+00:00","cve":"CVE-2020-8464","urls":{"html":"https://cve.report/CVE-2020-8464","api":"https://cve.report/api/cve/CVE-2020-8464.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-8464","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-8464"},"summary":{"title":"CVE-2020-8464","description":"A vulnerability in Trend Micro InterScan Web Security Virtual Appliance 6.5 SP2 could allow an attacker to send requests that appear to come from the localhost which could expose the product's admin interface to users who would not normally have access.","state":"PUBLIC","assigner":"security@trendmicro.com","published_at":"2020-12-17 21:15:00","updated_at":"2020-12-22 17:32:00"},"problem_types":["CWE-918"],"metrics":[],"references":[{"url":"https://sec-consult.com/vulnerability-lab/advisory/multiple-critical-vulnerabilities-in-trend-micro-interscan-web-security-virtual-appliance/","name":"N/A","refsource":"N/A","tags":["Exploit","Third Party Advisory"],"title":"Multiple critical vulnerabilities in Trend Micro InterScan Web Security Virtual Appliance (IWSVA)","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://success.trendmicro.com/solution/000283077","name":"N/A","refsource":"N/A","tags":["Vendor Advisory"],"title":"SECURITY BULLETIN:  December 2020 Security Bulletin for Trend Micro InterScan Web Security Virtual Appliance (IWSVA) 6.5 SP2","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-8464","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-8464","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2020","cve_id":"8464","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trendmicro","cpe5":"interscan_web_security_virtual_appliance","cpe6":"6.5","cpe7":"sp2","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"8464","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"trendmicro","cpe5":"interscan_web_security_virtual_appliance","cpe6":"6.5","cpe7":"sp2","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"security@trendmicro.com","ID":"CVE-2020-8464","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Trend Micro InterScan Web Security Virtual Appliance","version":{"version_data":[{"version_value":"6.5 SP2"}]}}]},"vendor_name":"Trend Micro"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability in Trend Micro InterScan Web Security Virtual Appliance 6.5 SP2 could allow an attacker to send requests that appear to come from the localhost which could expose the product's admin interface to users who would not normally have access."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Authentication Bypass"}]}]},"references":{"reference_data":[{"url":"https://success.trendmicro.com/solution/000283077","refsource":"MISC","name":"https://success.trendmicro.com/solution/000283077"},{"url":"https://sec-consult.com/vulnerability-lab/advisory/multiple-critical-vulnerabilities-in-trend-micro-interscan-web-security-virtual-appliance/","refsource":"MISC","name":"https://sec-consult.com/vulnerability-lab/advisory/multiple-critical-vulnerabilities-in-trend-micro-interscan-web-security-virtual-appliance/"}]}},"nvd":{"publishedDate":"2020-12-17 21:15:00","lastModifiedDate":"2020-12-22 17:32:00","problem_types":["CWE-918"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":7.5,"baseSeverity":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":5},"severity":"MEDIUM","exploitabilityScore":10,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:trendmicro:interscan_web_security_virtual_appliance:6.5:sp2:*:*:*:*:*:*","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"8464","Ordinal":"168803","Title":"CVE-2020-8464","CVE":"CVE-2020-8464","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"8464","Ordinal":"1","NoteData":"A vulnerability in Trend Micro InterScan Web Security Virtual Appliance 6.5 SP2 could allow an attacker to send requests that appear to come from the localhost which could expose the product's admin interface to users who would not normally have access.","Type":"Description","Title":null},{"CveYear":"2020","CveId":"8464","Ordinal":"2","NoteData":"2020-12-17","Type":"Other","Title":"Published"},{"CveYear":"2020","CveId":"8464","Ordinal":"3","NoteData":"2020-12-17","Type":"Other","Title":"Modified"}]}}}