{"api_version":"1","generated_at":"2026-04-23T02:35:31+00:00","cve":"CVE-2020-8473","urls":{"html":"https://cve.report/CVE-2020-8473","api":"https://cve.report/api/cve/CVE-2020-8473.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-8473","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-8473"},"summary":{"title":"CVE-2020-8473","description":"Insufficient folder permissions used by system functions in ABB System 800xA Base (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploit the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications.","state":"PUBLIC","assigner":"cybersecurity@ch.abb.com","published_at":"2020-04-29 00:15:00","updated_at":"2020-05-14 14:49:00"},"problem_types":["CWE-732"],"metrics":[],"references":[{"url":"https://search.abb.com/library/Download.aspx?DocumentID=2PAA121106&LanguageCode=en&DocumentPartId=&Action=Launch","name":"https://search.abb.com/library/Download.aspx?DocumentID=2PAA121106&LanguageCode=en&DocumentPartId=&Action=Launch","refsource":"CONFIRM","tags":["Vendor Advisory"],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"0"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-8473","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-8473","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2020","cve_id":"8473","vulnerable":"1","versionEndIncluding":"6.1","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"abb","cpe5":"800xa_base_system","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@ch.abb.com","ID":"CVE-2020-8473","STATE":"PUBLIC","TITLE":"ABB System 800xA Weak File Permissions - ABB System 800xA Base"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"ABB","product":{"product_data":[{"product_name":"System 800xA Base","version":{"version_data":[{"version_value":"6.1 and earlier"}]}}]}}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Insufficient folder permissions used by system functions in ABB System 800xA Base (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploit the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.3,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-732 Incorrect Permission Assignment for Critical Resource"}]}]},"references":{"reference_data":[{"refsource":"CONFIRM","name":"https://search.abb.com/library/Download.aspx?DocumentID=2PAA121106&LanguageCode=en&DocumentPartId=&Action=Launch","url":"https://search.abb.com/library/Download.aspx?DocumentID=2PAA121106&LanguageCode=en&DocumentPartId=&Action=Launch"}]},"source":{"discovery":"UNKNOWN"}},"nvd":{"publishedDate":"2020-04-29 00:15:00","lastModifiedDate":"2020-05-14 14:49:00","problem_types":["CWE-732"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:P/I:C/A:C","accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE","baseScore":6.8},"severity":"MEDIUM","exploitabilityScore":3.9,"impactScore":9.5,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:abb:800xa_base_system:*:*:*:*:*:*:*:*","versionEndIncluding":"6.1","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"8473","Ordinal":"168812","Title":"CVE-2020-8473","CVE":"CVE-2020-8473","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"8473","Ordinal":"1","NoteData":"Insufficient folder permissions used by system functions in ABB System 800xA Base (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploit the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications.","Type":"Description","Title":null},{"CveYear":"2020","CveId":"8473","Ordinal":"2","NoteData":"2020-04-28","Type":"Other","Title":"Published"},{"CveYear":"2020","CveId":"8473","Ordinal":"3","NoteData":"2020-04-28","Type":"Other","Title":"Modified"}]}}}