{"api_version":"1","generated_at":"2026-07-23T13:39:51+00:00","cve":"CVE-2020-8768","urls":{"html":"https://cve.report/CVE-2020-8768","api":"https://cve.report/api/cve/CVE-2020-8768.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2020-8768","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2020-8768"},"summary":{"title":"CVE-2020-8768","description":"An issue was discovered on Phoenix Contact Emalytics Controller ILC 2050 BI before 1.2.3 and BI-L before 1.2.3 devices. There is an insecure mechanism for read and write access to the configuration of the device. The mechanism can be discovered by examining a link on the website of the device.","state":"PUBLIC","assigner":"cve@mitre.org","published_at":"2020-02-17 21:15:00","updated_at":"2022-01-01 19:38:00"},"problem_types":["CWE-732"],"metrics":[],"references":[{"url":"https://cert.vde.com/de-de/advisories/vde-2020-001","name":"https://cert.vde.com/de-de/advisories/vde-2020-001","refsource":"MISC","tags":["Third Party Advisory"],"title":"PHOENIX CONTACT Emalytics Controller ILC 2050 BI(L) allows unauthorised read and write access to the configuration file. — German (Germany)","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.us-cert.gov/ics/advisories/icsa-20-063-02","name":"https://www.us-cert.gov/ics/advisories/icsa-20-063-02","refsource":"MISC","tags":[],"title":"PHOENIX CONTACT Emalytics Controller ILC | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2020-8768","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2020-8768","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2020","cve_id":"8768","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"phoenixcontact","cpe5":"ilc_2050_bi","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"8768","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"phoenixcontact","cpe5":"ilc_2050_bi","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"8768","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"phoenixcontact","cpe5":"ilc_2050_bi-l","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"8768","vulnerable":"0","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"phoenixcontact","cpe5":"ilc_2050_bi-l","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"8768","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"phoenixcontact","cpe5":"ilc_2050_bi-l_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"8768","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"phoenixcontact","cpe5":"ilc_2050_bi-l_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"8768","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"phoenixcontact","cpe5":"ilc_2050_bi_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2020","cve_id":"8768","vulnerable":"1","versionEndIncluding":"1","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"phoenixcontact","cpe5":"ilc_2050_bi_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2020-8768","qid":"590570","title":"PHOENIX CONTACT Emalytics Controller ILC Incorrect Permission Assignment for Critical Resource Vulnerability (ICSA-20-063-02)"}]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2020-8768","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An issue was discovered on Phoenix Contact Emalytics Controller ILC 2050 BI before 1.2.3 and BI-L before 1.2.3 devices. There is an insecure mechanism for read and write access to the configuration of the device. The mechanism can be discovered by examining a link on the website of the device."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://cert.vde.com/de-de/advisories/vde-2020-001","url":"https://cert.vde.com/de-de/advisories/vde-2020-001"},{"refsource":"MISC","name":"https://www.us-cert.gov/ics/advisories/icsa-20-063-02","url":"https://www.us-cert.gov/ics/advisories/icsa-20-063-02"}]}},"nvd":{"publishedDate":"2020-02-17 21:15:00","lastModifiedDate":"2022-01-01 19:38:00","problem_types":["CWE-732"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":9.4,"baseSeverity":"CRITICAL"},"exploitabilityScore":3.9,"impactScore":5.5},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":7.5},"severity":"HIGH","exploitabilityScore":10,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:phoenixcontact:ilc_2050_bi_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.2.3","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:phoenixcontact:ilc_2050_bi:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:phoenixcontact:ilc_2050_bi-l_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.2.3","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:phoenixcontact:ilc_2050_bi-l:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2020","CveId":"8768","Ordinal":"169109","Title":"CVE-2020-8768","CVE":"CVE-2020-8768","Year":"2020"},"notes":[{"CveYear":"2020","CveId":"8768","Ordinal":"1","NoteData":"An issue was discovered on Phoenix Contact Emalytics Controller ILC 2050 BI before 1.2.3 and BI-L before 1.2.3 devices. There is an insecure mechanism for read and write access to the configuration of the device. The mechanism can be discovered by examining a link on the website of the device.","Type":"Description","Title":null},{"CveYear":"2020","CveId":"8768","Ordinal":"2","NoteData":"2020-02-17","Type":"Other","Title":"Published"},{"CveYear":"2020","CveId":"8768","Ordinal":"3","NoteData":"2020-03-11","Type":"Other","Title":"Modified"}]}}}