{"api_version":"1","generated_at":"2026-07-23T10:33:28+00:00","cve":"CVE-2021-20140","urls":{"html":"https://cve.report/CVE-2021-20140","api":"https://cve.report/api/cve/CVE-2021-20140.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-20140","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-20140"},"summary":{"title":"CVE-2021-20140","description":"An unauthenticated command injection vulnerability exists in the parameters of operation 10 in the controller_server service on Gryphon Tower routers. An unauthenticated remote attacker on the same network can execute commands as root on the device by sending a specially crafted malicious packet to the controller_server service on port 9999.","state":"PUBLIC","assigner":"vulnreport@tenable.com","published_at":"2021-12-09 16:15:00","updated_at":"2021-12-13 18:07:00"},"problem_types":["CWE-78"],"metrics":[],"references":[{"url":"https://www.tenable.com/security/research/tra-2021-51","name":"https://www.tenable.com/security/research/tra-2021-51","refsource":"MISC","tags":[],"title":"Multiple Vulnerabilities in Gryphon Tower Router - Research Advisory | Tenable®","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-20140","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-20140","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"20140","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"gryphonconnect","cpe5":"gryphon_tower","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20140","vulnerable":"1","versionEndIncluding":"04.0004.12","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"gryphonconnect","cpe5":"gryphon_tower_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2021-20140","ASSIGNER":"vulnreport@tenable.com","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"Gryphon Tower router","version":{"version_data":[{"version_value":"<= 04.0004.12 (Current)"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Command Injection"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://www.tenable.com/security/research/tra-2021-51","url":"https://www.tenable.com/security/research/tra-2021-51"}]},"description":{"description_data":[{"lang":"eng","value":"An unauthenticated command injection vulnerability exists in the parameters of operation 10 in the controller_server service on Gryphon Tower routers. An unauthenticated remote attacker on the same network can execute commands as root on the device by sending a specially crafted malicious packet to the controller_server service on port 9999."}]}},"nvd":{"publishedDate":"2021-12-09 16:15:00","lastModifiedDate":"2021-12-13 18:07:00","problem_types":["CWE-78"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:A/AC:L/Au:N/C:C/I:C/A:C","accessVector":"ADJACENT_NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE","baseScore":8.3},"severity":"HIGH","exploitabilityScore":6.5,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:gryphonconnect:gryphon_tower_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"04.0004.12","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:gryphonconnect:gryphon_tower:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"20140","Ordinal":"194129","Title":"CVE-2021-20140","CVE":"CVE-2021-20140","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"20140","Ordinal":"1","NoteData":"An unauthenticated command injection vulnerability exists in the parameters of operation 10 in the controller_server service on Gryphon Tower routers. An unauthenticated remote attacker on the same network can execute commands as root on the device by sending a specially crafted malicious packet to the controller_server service on port 9999.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"20140","Ordinal":"2","NoteData":"2021-12-09","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"20140","Ordinal":"3","NoteData":"2021-12-09","Type":"Other","Title":"Modified"}]}}}