{"api_version":"1","generated_at":"2026-04-23T20:23:10+00:00","cve":"CVE-2021-20599","urls":{"html":"https://cve.report/CVE-2021-20599","api":"https://cve.report/api/cve/CVE-2021-20599.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-20599","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-20599"},"summary":{"title":"CVE-2021-20599","description":"Cleartext transmission of sensitive information vulnerability in MELSEC iQ-R series Safety CPU R08/16/32/120SFCPU firmware versions \"26\" and prior and MELSEC iQ-R series SIL2 Process CPU R08/16/32/120PSFCPU all versions allows a remote unauthenticated attacker to login to a target CPU module by obtaining credentials other than password.","state":"PUBLIC","assigner":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","published_at":"2021-10-14 15:15:00","updated_at":"2022-10-14 17:15:00"},"problem_types":["CWE-639"],"metrics":[],"references":[{"url":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-011_en.pdf","name":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-011_en.pdf","refsource":"MISC","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"200"},{"url":"https://jvn.jp/vu/JVNVU98578731","name":"https://jvn.jp/vu/JVNVU98578731","refsource":"MISC","tags":[],"title":"JVNVU#98578731: 三菱電機製 MELSEC iQ-R シリーズ CPU ユニットにおける複数の脆弱性","mime":"text/xml","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-21-287-03","name":"https://www.cisa.gov/uscert/ics/advisories/icsa-21-287-03","refsource":"MISC","tags":[],"title":"Mitsubishi Electric MELSEC iQ-R Series | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-20599","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-20599","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"20599","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"r08psfcpu","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20599","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"r08psfcpu_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20599","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"r08sfcpu","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20599","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"r08sfcpu_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20599","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"r120psfcpu","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20599","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"r120psfcpu_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20599","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"r120sfcpu","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20599","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"r120sfcpu_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20599","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"r16psfcpu","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20599","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"r16psfcpu_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20599","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"r16sfcpu","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20599","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"r16sfcpu_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20599","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"r32psfcpu","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20599","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"r32psfcpu_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20599","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"mitsubishielectric","cpe5":"r32sfcpu","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20599","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"mitsubishielectric","cpe5":"r32sfcpu_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2021-20599","qid":"590650","title":"Mitsubishi Electric MELSEC iQ-R Series Authorization Bypass Through User-controlled Key Vulnerability (ICSA-21-287-03)"}]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2021-20599","ASSIGNER":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"Mitsubishi Electric MELSEC iQ-R series Safety CPU R08/16/32/120SFCPU; Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU R08/16/32/120PSFCPU","version":{"version_data":[{"version_value":"Mitsubishi Electric MELSEC iQ-R series Safety CPU R08/16/32/120SFCPU Firmware versions \"26\" and prior"},{"version_value":"Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU R08/16/32/120PSFCPU All versions"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Cleartext transmission of sensitive information"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-011_en.pdf","url":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-011_en.pdf"},{"refsource":"MISC","name":"https://jvn.jp/vu/JVNVU98578731","url":"https://jvn.jp/vu/JVNVU98578731"},{"refsource":"MISC","name":"https://www.cisa.gov/uscert/ics/advisories/icsa-21-287-03","url":"https://www.cisa.gov/uscert/ics/advisories/icsa-21-287-03"}]},"description":{"description_data":[{"lang":"eng","value":"Cleartext transmission of sensitive information vulnerability in MELSEC iQ-R series Safety CPU R08/16/32/120SFCPU firmware versions \"26\" and prior and MELSEC iQ-R series SIL2 Process CPU R08/16/32/120PSFCPU all versions allows a remote unauthenticated attacker to login to a target CPU module by obtaining credentials other than password."}]}},"nvd":{"publishedDate":"2021-10-14 15:15:00","lastModifiedDate":"2022-10-14 17:15:00","problem_types":["CWE-639"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":7.5,"baseSeverity":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":5},"severity":"MEDIUM","exploitabilityScore":10,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:r08sfcpu_firmware:*:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:r08sfcpu:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:r16sfcpu_firmware:*:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:r16sfcpu:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:r32sfcpu_firmware:*:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:r32sfcpu:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:r120sfcpu_firmware:*:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:r120sfcpu:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:r08psfcpu_firmware:*:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:r08psfcpu:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:r16psfcpu_firmware:*:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:r16psfcpu:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:r32psfcpu_firmware:*:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:r32psfcpu:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:mitsubishielectric:r120psfcpu_firmware:*:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:mitsubishielectric:r120psfcpu:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"20599","Ordinal":"194644","Title":"CVE-2021-20599","CVE":"CVE-2021-20599","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"20599","Ordinal":"1","NoteData":"Authorization bypass through user-controlled key vulnerability in MELSEC iQ-R series Safety CPU R08/16/32/120SFCPU all versions and MELSEC iQ-R series SIL2 Process CPU R08/16/32/120PSFCPU all versions allows an remote unauthenticated attacker to login to a target CPU module by obtaining credentials other than password.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"20599","Ordinal":"2","NoteData":"2021-10-14","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"20599","Ordinal":"3","NoteData":"2021-10-14","Type":"Other","Title":"Modified"}]}}}