{"api_version":"1","generated_at":"2026-04-23T20:20:46+00:00","cve":"CVE-2021-20608","urls":{"html":"https://cve.report/CVE-2021-20608","api":"https://cve.report/api/cve/CVE-2021-20608.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-20608","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-20608"},"summary":{"title":"CVE-2021-20608","description":"Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior allows a remote unauthenticated attacker to cause a DoS condition in GX Works2 by getting GX Works2 to read a tampered program file from a Mitsubishi Electric PLC by sending malicious crafted packets to tamper with the program file.","state":"PUBLIC","assigner":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","published_at":"2021-12-17 17:15:00","updated_at":"2021-12-27 18:30:00"},"problem_types":["NVD-CWE-Other"],"metrics":[],"references":[{"url":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-020_en.pdf","name":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-020_en.pdf","refsource":"MISC","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"200"},{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-350-04","name":"https://us-cert.cisa.gov/ics/advisories/icsa-21-350-04","refsource":"MISC","tags":[],"title":"Mitsubishi Electric GX Works2 | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://jvn.jp/vu/JVNVU93019896/index.html","name":"https://jvn.jp/vu/JVNVU93019896/index.html","refsource":"MISC","tags":[],"title":"JVNVU#93019896: 三菱電機製GX Works2における長さパラメータの不整合時の不適切な取り扱いに関する脆弱性","mime":"text/xml","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-20608","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-20608","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"20608","vulnerable":"1","versionEndIncluding":"1.606g","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"mitsubishielectric","cpe5":"gx_works2","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2021-20608","qid":"590797","title":"Mitsubishi Electric GX Works2 Denial of Service (DoS) Vulnerability (ICSA-21-350-04)"}]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2021-20608","ASSIGNER":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"GX Works2","version":{"version_data":[{"version_value":"versions 1.606G and prior"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Improper Handling of Length Parameter Inconsistency"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-020_en.pdf","url":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-020_en.pdf"},{"refsource":"MISC","name":"https://jvn.jp/vu/JVNVU93019896/index.html","url":"https://jvn.jp/vu/JVNVU93019896/index.html"},{"refsource":"MISC","name":"https://us-cert.cisa.gov/ics/advisories/icsa-21-350-04","url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-350-04"}]},"description":{"description_data":[{"lang":"eng","value":"Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior allows a remote unauthenticated attacker to cause a DoS condition in GX Works2 by getting GX Works2 to read a tampered program file from a Mitsubishi Electric PLC by sending malicious crafted packets to tamper with the program file."}]}},"nvd":{"publishedDate":"2021-12-17 17:15:00","lastModifiedDate":"2021-12-27 18:30:00","problem_types":["NVD-CWE-Other"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:P","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL","baseScore":5},"severity":"MEDIUM","exploitabilityScore":10,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*","versionEndIncluding":"1.606g","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"20608","Ordinal":"194653","Title":"CVE-2021-20608","CVE":"CVE-2021-20608","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"20608","Ordinal":"1","NoteData":"Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior allows a remote unauthenticated attacker to cause a DoS condition in GX Works2 by getting GX Works2 to read a tampered program file from a Mitsubishi Electric PLC by sending malicious crafted packets to tamper with the program file.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"20608","Ordinal":"2","NoteData":"2021-12-17","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"20608","Ordinal":"3","NoteData":"2021-12-17","Type":"Other","Title":"Modified"}]}}}