{"api_version":"1","generated_at":"2026-04-23T10:44:16+00:00","cve":"CVE-2021-20999","urls":{"html":"https://cve.report/CVE-2021-20999","api":"https://cve.report/api/cve/CVE-2021-20999.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-20999","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-20999"},"summary":{"title":"CVE-2021-20999","description":"In Weidmüller u-controls and IoT-Gateways in versions up to 1.12.1 a network port intended only for device-internal usage is accidentally accessible via external network interfaces. By exploiting this vulnerability the device may be manipulated or the operation may be stopped.","state":"PUBLIC","assigner":"info@cert.vde.com","published_at":"2021-05-13 14:15:00","updated_at":"2023-11-07 03:29:00"},"problem_types":["NVD-CWE-Other"],"metrics":[],"references":[{"url":"https://cert.vde.com/en-us/advisories/vde-2021-016","name":"https://cert.vde.com/en-us/advisories/vde-2021-016","refsource":"CONFIRM","tags":[],"title":"WEIDMUELLER: Accidentally open network port in u-controls and IoT-Gateways — English (USA)","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-20999","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-20999","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"LEGACY","value":"Reported by Weidmüller.","lang":""}],"nvd_cpes":[{"cve_year":"2021","cve_id":"20999","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"weidmueller","cpe5":"iot-gw30","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20999","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"weidmueller","cpe5":"iot-gw30-4g-eu","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20999","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"weidmueller","cpe5":"iot-gw30-4g-eu_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20999","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"weidmueller","cpe5":"iot-gw30-4g-eu_firmware","cpe6":"1.11.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20999","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"weidmueller","cpe5":"iot-gw30-4g-eu_firmware","cpe6":"1.12.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20999","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"weidmueller","cpe5":"iot-gw30_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20999","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"weidmueller","cpe5":"iot-gw30_firmware","cpe6":"1.11.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20999","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"weidmueller","cpe5":"iot-gw30_firmware","cpe6":"1.12.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20999","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"weidmueller","cpe5":"uc20-wl2000-ac","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20999","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"weidmueller","cpe5":"uc20-wl2000-ac_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20999","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"weidmueller","cpe5":"uc20-wl2000-ac_firmware","cpe6":"1.11.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20999","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"weidmueller","cpe5":"uc20-wl2000-ac_firmware","cpe6":"1.12.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20999","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"weidmueller","cpe5":"uc20-wl2000-iot","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20999","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"weidmueller","cpe5":"uc20-wl2000-iot_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20999","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"weidmueller","cpe5":"uc20-wl2000-iot_firmware","cpe6":"1.11.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"20999","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"weidmueller","cpe5":"uc20-wl2000-iot_firmware","cpe6":"1.12.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"info@cert.vde.com","DATE_PUBLIC":"2021-05-04T10:00:00.000Z","ID":"CVE-2021-20999","STATE":"PUBLIC","TITLE":"WEIDMUELLER: Accidentally open network port in u-controls and IoT-Gateways"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"UC20-WL2000-AC (No. 1334950000)","version":{"version_data":[{"version_affected":"<=","version_name":"1.3.0","version_value":"1.9.0"},{"version_affected":"<=","version_name":"1.10.0","version_value":"1.10.2"},{"version_affected":"<=","version_name":"1.11.0","version_value":"1.12.1"}]}},{"product_name":"UC20-WL2000-IOT (No. 1334990000)","version":{"version_data":[{"version_affected":"<=","version_name":"1.3.0","version_value":"1.9.0"},{"version_affected":"<=","version_name":"1.10.0","version_value":"1.10.2"},{"version_affected":"<=","version_name":"1.11.0","version_value":"1.12.1"}]}},{"product_name":"IOT-GW30 (No. 2682620000)","version":{"version_data":[{"version_affected":"<=","version_name":"1.3.0","version_value":"1.9.0"},{"version_affected":"<=","version_name":"1.10.0","version_value":"1.10.2"},{"version_affected":"<=","version_name":"1.11.0","version_value":"1.12.1"}]}},{"product_name":"IOT-GW30-4G-EU (No. 2682630000)","version":{"version_data":[{"version_affected":"<=","version_name":"1.3.0","version_value":"1.9.0"},{"version_affected":"<=","version_name":"1.10.0","version_value":"1.10.2"},{"version_affected":"<=","version_name":"1.11.0","version_value":"1.12.1"}]}}]},"vendor_name":"Weidmüller"}]}},"credit":[{"lang":"eng","value":"Reported by Weidmüller."}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"In Weidmüller u-controls and IoT-Gateways in versions up to 1.12.1 a network port intended only for device-internal usage is accidentally accessible via external network interfaces. By exploiting this vulnerability the device may be manipulated or the operation may be stopped."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.4,"baseSeverity":"CRITICAL","confidentialityImpact":"LOW","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-668 Exposure of Resource to Wrong Sphere"}]}]},"references":{"reference_data":[{"name":"https://cert.vde.com/en-us/advisories/vde-2021-016","refsource":"CONFIRM","url":"https://cert.vde.com/en-us/advisories/vde-2021-016"}]},"solution":[{"lang":"eng","value":"Weidmüller recommends upgrading affected devices to the current firmware version 1.12.3 or higher which fixes this vulnerability."}],"source":{"advisory":"VDE-2021-016","defect":["VDE-2021-016"],"discovery":"INTERNAL"},"work_around":[{"lang":"eng","value":"Restrict access to the network the device is connected to.\nDo not directly connect the device to the internet."}]},"nvd":{"publishedDate":"2021-05-13 14:15:00","lastModifiedDate":"2023-11-07 03:29:00","problem_types":["NVD-CWE-Other"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL"},"exploitabilityScore":3.9,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":7.5},"severity":"HIGH","exploitabilityScore":10,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:weidmueller:uc20-wl2000-ac_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"1.3.0","versionEndExcluding":"1.9.1","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:weidmueller:uc20-wl2000-ac_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"1.10.0","versionEndExcluding":"1.10.3","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:weidmueller:uc20-wl2000-ac_firmware:1.11.0:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:weidmueller:uc20-wl2000-ac_firmware:1.12.1:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:weidmueller:uc20-wl2000-ac:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:weidmueller:uc20-wl2000-iot_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"1.3.0","versionEndExcluding":"1.9.1","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:weidmueller:uc20-wl2000-iot_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"1.10.0","versionEndExcluding":"1.10.3","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:weidmueller:uc20-wl2000-iot_firmware:1.11.0:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:weidmueller:uc20-wl2000-iot_firmware:1.12.1:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:weidmueller:uc20-wl2000-iot:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:weidmueller:iot-gw30_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"1.3.0","versionEndExcluding":"1.9.1","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:weidmueller:iot-gw30_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"1.10.0","versionEndExcluding":"1.10.3","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:weidmueller:iot-gw30_firmware:1.11.0:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:weidmueller:iot-gw30_firmware:1.12.1:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:weidmueller:iot-gw30:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:weidmueller:iot-gw30-4g-eu_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"1.3.0","versionEndExcluding":"1.9.1","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:weidmueller:iot-gw30-4g-eu_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"1.10.0","versionEndExcluding":"1.10.3","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:weidmueller:iot-gw30-4g-eu_firmware:1.11.0:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:weidmueller:iot-gw30-4g-eu_firmware:1.12.1:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:weidmueller:iot-gw30-4g-eu:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"20999","Ordinal":"195044","Title":"CVE-2021-20999","CVE":"CVE-2021-20999","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"20999","Ordinal":"1","NoteData":"In Weidmüller u-controls and IoT-Gateways in versions up to 1.12.1 a network port intended only for device-internal usage is accidentally accessible via external network interfaces. By exploiting this vulnerability the device may be manipulated or the operation may be stopped.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"20999","Ordinal":"2","NoteData":"2021-05-13","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"20999","Ordinal":"3","NoteData":"2021-05-13","Type":"Other","Title":"Modified"}]}}}