{"api_version":"1","generated_at":"2026-04-23T17:03:53+00:00","cve":"CVE-2021-21819","urls":{"html":"https://cve.report/CVE-2021-21819","api":"https://cve.report/api/cve/CVE-2021-21819.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-21819","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-21819"},"summary":{"title":"CVE-2021-21819","description":"A code execution vulnerability exists in the Libcli Test Environment functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to arbitrary command execution. An attacker can send a sequence of requests to trigger this vulnerability.","state":"PUBLIC","assigner":"talos-cna@cisco.com","published_at":"2021-07-16 11:15:00","updated_at":"2022-07-29 14:52:00"},"problem_types":["CWE-78"],"metrics":[],"references":[{"url":"https://talosintelligence.com/vulnerability_reports/TALOS-2021-1284","name":"https://talosintelligence.com/vulnerability_reports/TALOS-2021-1284","refsource":"MISC","tags":[],"title":"TALOS-2021-1284 ||  Cisco Talos Intelligence Group - Comprehensive Threat Intelligence","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-21819","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-21819","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"21819","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"dlink","cpe5":"dir-3040","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"21819","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"dlink","cpe5":"dir-3040_firmware","cpe6":"1.13b03","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2021-21819","ASSIGNER":"talos-cna@cisco.com","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"D-Link","version":{"version_data":[{"version_value":"D-LINK DIR-3040 1.13B03"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://talosintelligence.com/vulnerability_reports/TALOS-2021-1284","url":"https://talosintelligence.com/vulnerability_reports/TALOS-2021-1284"}]},"description":{"description_data":[{"lang":"eng","value":"A code execution vulnerability exists in the Libcli Test Environment functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to arbitrary command execution. An attacker can send a sequence of requests to trigger this vulnerability."}]},"impact":{"cvss":{"baseScore":9.1,"baseSeverity":"Critical","vectorString":"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","version":"3.0"}}},"nvd":{"publishedDate":"2021-07-16 11:15:00","lastModifiedDate":"2022-07-29 14:52:00","problem_types":["CWE-78"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.2,"baseSeverity":"HIGH"},"exploitabilityScore":1.2,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE","baseScore":9},"severity":"HIGH","exploitabilityScore":8,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:dlink:dir-3040_firmware:1.13b03:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:dlink:dir-3040:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"21819","Ordinal":"196508","Title":"CVE-2021-21819","CVE":"CVE-2021-21819","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"21819","Ordinal":"1","NoteData":"A code execution vulnerability exists in the Libcli Test Environment functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to arbitrary command execution. An attacker can send a sequence of requests to trigger this vulnerability.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"21819","Ordinal":"2","NoteData":"2021-07-16","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"21819","Ordinal":"3","NoteData":"2021-07-16","Type":"Other","Title":"Modified"}]}}}