{"api_version":"1","generated_at":"2026-04-23T01:33:13+00:00","cve":"CVE-2021-22699","urls":{"html":"https://cve.report/CVE-2021-22699","api":"https://cve.report/api/cve/CVE-2021-22699.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-22699","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-22699"},"summary":{"title":"CVE-2021-22699","description":"Improper Input Validation vulnerability exists in Modicon M241/M251 logic controllers firmware prior to V5.1.9.1 that could cause denial of service when specific crafted requests are sent to the controller over HTTP.","state":"PUBLIC","assigner":"cybersecurity@schneider-electric.com","published_at":"2021-05-26 20:15:00","updated_at":"2022-02-03 16:14:00"},"problem_types":["CWE-20"],"metrics":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-05","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-05","refsource":"MISC","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-22699","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-22699","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"22699","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"modicon_m241","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"22699","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"schneider-electric","cpe5":"modicon_m241_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"22699","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"modicon_m251","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"22699","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"schneider-electric","cpe5":"modicon_m251_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"22699","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"se","cpe5":"modicon_m241","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"22699","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"se","cpe5":"modicon_m241_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"22699","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"se","cpe5":"modicon_m251","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"22699","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"se","cpe5":"modicon_m251_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2021-22699","qid":"590812","title":"Schneider Electric Modicon M241 and M251 Logic Controllers Vulnerability (SEVD-2021-130-05)"}]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2021-22699","ASSIGNER":"cybersecurity@schneider-electric.com","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"Modicon M241/M251 logic controllers firmware prior to V5.1.9.1","version":{"version_data":[{"version_value":"Modicon M241/M251 logic controllers firmware prior to V5.1.9.1"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-20: Improper Input Validation"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-05","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-05"}]},"description":{"description_data":[{"lang":"eng","value":"Improper Input Validation vulnerability exists in Modicon M241/M251 logic controllers firmware prior to V5.1.9.1 that could cause denial of service when specific crafted requests are sent to the controller over HTTP."}]}},"nvd":{"publishedDate":"2021-05-26 20:15:00","lastModifiedDate":"2022-02-03 16:14:00","problem_types":["CWE-20"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:C","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"COMPLETE","baseScore":7.8},"severity":"HIGH","exploitabilityScore":10,"impactScore":6.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:schneider-electric:modicon_m241_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"5.1.9.1","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:schneider-electric:modicon_m241:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:schneider-electric:modicon_m251_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"5.1.9.1","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:schneider-electric:modicon_m251:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"22699","Ordinal":"197431","Title":"CVE-2021-22699","CVE":"CVE-2021-22699","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"22699","Ordinal":"1","NoteData":"Improper Input Validation vulnerability exists in Modicon M241/M251 logic controllers firmware prior to V5.1.9.1 that could cause denial of service when specific crafted requests are sent to the controller over HTTP.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"22699","Ordinal":"2","NoteData":"2021-05-26","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"22699","Ordinal":"3","NoteData":"2021-05-26","Type":"Other","Title":"Modified"}]}}}