{"api_version":"1","generated_at":"2026-07-23T23:05:07+00:00","cve":"CVE-2021-22710","urls":{"html":"https://cve.report/CVE-2021-22710","api":"https://cve.report/api/cve/CVE-2021-22710.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-22710","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-22710"},"summary":{"title":"CVE-2021-22710","description":"A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could cause remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.","state":"PUBLIC","assigner":"cybersecurity@schneider-electric.com","published_at":"2021-03-11 21:15:00","updated_at":"2021-03-18 19:31:00"},"problem_types":["CWE-119"],"metrics":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01","refsource":"MISC","tags":["Patch","Vendor Advisory"],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://www.se.com/ww/en/download/document/SEVD-2021-068-01","name":"https://www.se.com/ww/en/download/document/SEVD-2021-068-01","refsource":"MISC","tags":["Broken Link","Vendor Advisory"],"title":"My List","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-22710","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-22710","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"22710","vulnerable":"1","versionEndIncluding":"15.0.0.21041","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"interactive_graphical_scada_system","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2021-22710","ASSIGNER":"cybersecurity@schneider-electric.com","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior","version":{"version_data":[{"version_value":"Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://www.se.com/ww/en/download/document/SEVD-2021-068-01","url":"https://www.se.com/ww/en/download/document/SEVD-2021-068-01"},{"refsource":"MISC","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01"}]},"description":{"description_data":[{"lang":"eng","value":"A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could cause remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition."}]}},"nvd":{"publishedDate":"2021-03-11 21:15:00","lastModifiedDate":"2021-03-18 19:31:00","problem_types":["CWE-119"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:C/I:C/A:C","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE","baseScore":9.3},"severity":"HIGH","exploitabilityScore":8.6,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*","versionEndIncluding":"15.0.0.21041","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"22710","Ordinal":"197442","Title":"CVE-2021-22710","CVE":"CVE-2021-22710","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"22710","Ordinal":"1","NoteData":"A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could cause remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"22710","Ordinal":"2","NoteData":"2021-03-11","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"22710","Ordinal":"3","NoteData":"2021-03-11","Type":"Other","Title":"Modified"}]}}}