{"api_version":"1","generated_at":"2026-07-24T21:11:12+00:00","cve":"CVE-2021-22716","urls":{"html":"https://cve.report/CVE-2021-22716","api":"https://cve.report/api/cve/CVE-2021-22716.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-22716","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-22716"},"summary":{"title":"CVE-2021-22716","description":"A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)","state":"PUBLIC","assigner":"cybersecurity@schneider-electric.com","published_at":"2021-04-13 19:15:00","updated_at":"2022-11-18 23:15:00"},"problem_types":["CWE-732"],"metrics":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01","refsource":"MISC","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"200"},{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-105-01","name":"https://us-cert.cisa.gov/ics/advisories/icsa-21-105-01","refsource":"MISC","tags":[],"title":"Schneider Electric C-Bus Toolkit | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2021-103-01_C-Bus_Toolkit_C-Gate_Server_Security_Notification.pdf","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2021-103-01_C-Bus_Toolkit_C-Gate_Server_Security_Notification.pdf","refsource":"MISC","tags":[],"title":"","mime":"","httpstatus":"-1","archivestatus":"404"},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-21-562/","name":"https://www.zerodayinitiative.com/advisories/ZDI-21-562/","refsource":"MISC","tags":[],"title":"ZDI-21-562 | Zero Day Initiative","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-22716","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-22716","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"22716","vulnerable":"1","versionEndIncluding":"1.15.7","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"c-bus_toolkit","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","DATE_PUBLIC":"2022-11-08T16:45:00.000Z","ID":"CVE-2021-22716","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"C-Bus Toolkit","version":{"version_data":[{"version_affected":"<","version_name":"V","version_value":"1.15.9"}]}}]},"vendor_name":"Schneider Electric"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)"}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-732 Incorrect Permission Assignment for Critical Resource"}]}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2021-103-01_C-Bus_Toolkit_C-Gate_Server_Security_Notification.pdf","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2021-103-01_C-Bus_Toolkit_C-Gate_Server_Security_Notification.pdf"},{"refsource":"MISC","url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-105-01","name":"https://us-cert.cisa.gov/ics/advisories/icsa-21-105-01"}]},"source":{"discovery":"UNKNOWN"}},"nvd":{"publishedDate":"2021-04-13 19:15:00","lastModifiedDate":"2022-11-18 23:15:00","problem_types":["CWE-732"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:P/I:P/A:P","accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":4.6},"severity":"MEDIUM","exploitabilityScore":3.9,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:c-bus_toolkit:*:*:*:*:*:*:*:*","versionEndIncluding":"1.15.7","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"22716","Ordinal":"197448","Title":"CVE-2021-22716","CVE":"CVE-2021-22716","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"22716","Ordinal":"1","NoteData":"A CWE-269: Improper Privilege Management vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when an unprivileged user modifies a file.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"22716","Ordinal":"2","NoteData":"2021-04-13","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"22716","Ordinal":"3","NoteData":"2021-05-11","Type":"Other","Title":"Modified"}]}}}