{"api_version":"1","generated_at":"2026-07-23T20:14:24+00:00","cve":"CVE-2021-22752","urls":{"html":"https://cve.report/CVE-2021-22752","api":"https://cve.report/api/cve/CVE-2021-22752.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-22752","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-22752"},"summary":{"title":"CVE-2021-22752","description":"A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing size checks, when a malicious WSP (Workspace) file is being parsed by IGSS Definition.","state":"PUBLIC","assigner":"cybersecurity@schneider-electric.com","published_at":"2021-06-11 16:15:00","updated_at":"2021-06-15 18:42:00"},"problem_types":["CWE-787"],"metrics":[],"references":[{"url":"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-01","name":"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-01","refsource":"MISC","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-22752","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-22752","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"22752","vulnerable":"1","versionEndIncluding":"15.0.0.21140","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"interactive_graphical_scada_system","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2021-22752","ASSIGNER":"cybersecurity@schneider-electric.com","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"IGSS Definition (Def.exe) V15.0.0.21140 and prior","version":{"version_data":[{"version_value":"IGSS Definition (Def.exe) V15.0.0.21140 and prior"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-787: Out-of-bounds write"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-01","url":"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-01"}]},"description":{"description_data":[{"lang":"eng","value":"A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing size checks, when a malicious WSP (Workspace) file is being parsed by IGSS Definition."}]}},"nvd":{"publishedDate":"2021-06-11 16:15:00","lastModifiedDate":"2021-06-15 18:42:00","problem_types":["CWE-787"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":6.8},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*","versionEndIncluding":"15.0.0.21140","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"22752","Ordinal":"197484","Title":"CVE-2021-22752","CVE":"CVE-2021-22752","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"22752","Ordinal":"1","NoteData":"A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing size checks, when a malicious WSP (Workspace) file is being parsed by IGSS Definition.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"22752","Ordinal":"2","NoteData":"2021-06-11","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"22752","Ordinal":"3","NoteData":"2021-06-11","Type":"Other","Title":"Modified"}]}}}