{"api_version":"1","generated_at":"2026-07-24T00:04:11+00:00","cve":"CVE-2021-22793","urls":{"html":"https://cve.report/CVE-2021-22793","api":"https://cve.report/api/cve/CVE-2021-22793.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-22793","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-22793"},"summary":{"title":"CVE-2021-22793","description":"A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exist in AccuSine PCS+ / PFV+ (Versions prior to V1.6.7) and AccuSine PCSn (Versions prior to V2.2.4) that could allow an authenticated attacker to access the device via FTP protocol.","state":"PUBLIC","assigner":"cybersecurity@schneider-electric.com","published_at":"2021-09-02 17:15:00","updated_at":"2021-09-13 20:26:00"},"problem_types":["CWE-200"],"metrics":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-05","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-05","refsource":"MISC","tags":["Patch","Vendor Advisory"],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"200"},{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-01","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-01","refsource":"MISC","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-22793","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-22793","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"22793","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"accusine_pcsn","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"22793","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"schneider-electric","cpe5":"accusine_pcsn_active_harmonic_filter_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"22793","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"schneider-electric","cpe5":"accusine_pcsp_pfvp_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"22793","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"accusine_pcs\\+","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"22793","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"schneider-electric","cpe5":"accusine_pfv\\+","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2021-22793","qid":"590784","title":"Schneider Electric AccuSine PCSn/PCS+/PFV+ Vulnerability (SEVD-2021-222-05)"}]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2021-22793","ASSIGNER":"cybersecurity@schneider-electric.com","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"AccuSine PCS+ / PFV+ (Versions prior to V1.6.7) and AccuSine PCSn (Versions prior to V2.2.4)","version":{"version_data":[{"version_value":"AccuSine PCS+ / PFV+ (Versions prior to V1.6.7) and AccuSine PCSn (Versions prior to V2.2.4)"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-200: Exposure of Sensitive Information to an Unauthorized Actor"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-01","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-01"}]},"description":{"description_data":[{"lang":"eng","value":"A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exist in AccuSine PCS+ / PFV+ (Versions prior to V1.6.7) and AccuSine PCSn (Versions prior to V2.2.4) that could allow an authenticated attacker to access the device via FTP protocol."}]}},"nvd":{"publishedDate":"2021-09-02 17:15:00","lastModifiedDate":"2021-09-13 20:26:00","problem_types":["CWE-200"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.2,"baseSeverity":"HIGH"},"exploitabilityScore":1.2,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":6.5},"severity":"MEDIUM","exploitabilityScore":8,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:schneider-electric:accusine_pcsp_pfvp_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"001.006.007","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:schneider-electric:accusine_pcs\\+:-:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:schneider-electric:accusine_pfv\\+:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:schneider-electric:accusine_pcsn_active_harmonic_filter_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"002.002.004","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:schneider-electric:accusine_pcsn:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"22793","Ordinal":"197525","Title":"CVE-2021-22793","CVE":"CVE-2021-22793","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"22793","Ordinal":"1","NoteData":"A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exist in AccuSine PCS+ / PFV+ (Versions prior to V1.6.7) and AccuSine PCSn (Versions prior to V2.2.4) that could allow an authenticated attacker to access the device via FTP protocol.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"22793","Ordinal":"2","NoteData":"2021-09-02","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"22793","Ordinal":"3","NoteData":"2021-09-02","Type":"Other","Title":"Modified"}]}}}