{"api_version":"1","generated_at":"2026-07-23T13:22:11+00:00","cve":"CVE-2021-22796","urls":{"html":"https://cve.report/CVE-2021-22796","api":"https://cve.report/api/cve/CVE-2021-22796.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-22796","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-22796"},"summary":{"title":"CVE-2021-22796","description":"A CWE-287: Improper Authentication vulnerability exists that could allow remote code execution when a malicious file is uploaded. Affected Product: C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)","state":"PUBLIC","assigner":"cybersecurity@schneider-electric.com","published_at":"2022-02-11 18:15:00","updated_at":"2022-02-23 19:53:00"},"problem_types":["CWE-287"],"metrics":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01","refsource":"MISC","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-22796","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-22796","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"22796","vulnerable":"1","versionEndIncluding":"2.11.7","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"schneider-electric","cpe5":"c-gate_server","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2021-22796","ASSIGNER":"cybersecurity@schneider-electric.com","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)","version":{"version_data":[{"version_value":"C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-287: Improper Authentication"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01"}]},"description":{"description_data":[{"lang":"eng","value":"A CWE-287: Improper Authentication vulnerability exists that could allow remote code execution when a malicious file is uploaded. Affected Product: C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)"}]}},"nvd":{"publishedDate":"2022-02-11 18:15:00","lastModifiedDate":"2022-02-23 19:53:00","problem_types":["CWE-287"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":6.8},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:schneider-electric:c-gate_server:*:*:*:*:*:*:*:*","versionEndIncluding":"2.11.7","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"22796","Ordinal":"197528","Title":"CVE-2021-22796","CVE":"CVE-2021-22796","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"22796","Ordinal":"1","NoteData":"A CWE-287: Improper Authentication vulnerability exists that could allow remote code execution when a malicious file is uploaded. Affected Product: C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)","Type":"Description","Title":null},{"CveYear":"2021","CveId":"22796","Ordinal":"2","NoteData":"2022-02-11","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"22796","Ordinal":"3","NoteData":"2022-02-11","Type":"Other","Title":"Modified"}]}}}