{"api_version":"1","generated_at":"2026-04-23T04:10:52+00:00","cve":"CVE-2021-23281","urls":{"html":"https://cve.report/CVE-2021-23281","api":"https://cve.report/api/cve/CVE-2021-23281.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-23281","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-23281"},"summary":{"title":"CVE-2021-23281","description":"Eaton Intelligent Power Manager (IPM) prior to 1.69 is vulnerable to unauthenticated remote code execution vulnerability. IPM software does not sanitize the date provided via coverterCheckList action in meta_driver_srv.js class. Attackers can send a specially crafted packet to make IPM connect to rouge SNMP server and execute attacker-controlled code.","state":"PUBLIC","assigner":"CybersecurityCOE@eaton.com","published_at":"2021-04-13 19:15:00","updated_at":"2021-04-20 17:55:00"},"problem_types":["CWE-94"],"metrics":[],"references":[{"url":"https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-intelligent-power-manager-ipm-vulnerability-advisory.pdf","name":"https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-intelligent-power-manager-ipm-vulnerability-advisory.pdf","refsource":"MISC","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-23281","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-23281","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"LEGACY","value":"Amir Preminger from Claroty research","lang":""}],"nvd_cpes":[{"cve_year":"2021","cve_id":"23281","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"eaton","cpe5":"intelligent_power_manager","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"AKA":"Code Injection","ASSIGNER":"CybersecurityCOE@eaton.com","DATE_PUBLIC":"2021-04-01T07:00:00.000Z","ID":"CVE-2021-23281","STATE":"PUBLIC","TITLE":"Remote Code execution"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Intelligent Power manager (IPM)","version":{"version_data":[{"version_affected":"<","version_value":"1.69"}]}}]},"vendor_name":"Eaton"}]}},"credit":[{"lang":"eng","value":"Amir Preminger from Claroty research "}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Eaton Intelligent Power Manager (IPM) prior to 1.69 is vulnerable to unauthenticated remote code execution vulnerability. IPM software does not sanitize the date provided via coverterCheckList action in meta_driver_srv.js class. Attackers can send a specially crafted packet to make IPM connect to rouge SNMP server and execute attacker-controlled code."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":10,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-94 Improper Control of Generation of Code ('Code Injection')"}]}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-intelligent-power-manager-ipm-vulnerability-advisory.pdf","name":"https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-intelligent-power-manager-ipm-vulnerability-advisory.pdf"}]},"solution":[{"lang":"eng","value":"upgrade the software to latest version 1.69"}],"source":{"advisory":"ETN-VA-2021-1000","defect":["ETN-VA-2021-1000"],"discovery":"EXTERNAL"},"work_around":[{"lang":"eng","value":"To prevent the exploitation of the issues and safeguard the software from malicious entities, Eaton recommends blocking ports 4679 & 4680 at the enterprise network or home network where Intelligent Power Manager (IPM) software is installed and used"}]},"nvd":{"publishedDate":"2021-04-13 19:15:00","lastModifiedDate":"2021-04-20 17:55:00","problem_types":["CWE-94"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":10,"baseSeverity":"CRITICAL"},"exploitabilityScore":3.9,"impactScore":6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":7.5},"severity":"HIGH","exploitabilityScore":10,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:eaton:intelligent_power_manager:*:*:*:*:*:*:*:*","versionEndExcluding":"1.69","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"23281","Ordinal":"198008","Title":"CVE-2021-23281","CVE":"CVE-2021-23281","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"23281","Ordinal":"1","NoteData":"Eaton Intelligent Power Manager (IPM) prior to 1.69 is vulnerable to unauthenticated remote code execution vulnerability. IPM software does not sanitize the date provided via coverterCheckList action in meta_driver_srv.js class. Attackers can send a specially crafted packet to make IPM connect to rouge SNMP server and execute attacker-controlled code.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"23281","Ordinal":"2","NoteData":"2021-04-13","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"23281","Ordinal":"3","NoteData":"2021-04-13","Type":"Other","Title":"Modified"}]}}}