{"api_version":"1","generated_at":"2026-07-24T00:13:30+00:00","cve":"CVE-2021-27208","urls":{"html":"https://cve.report/CVE-2021-27208","api":"https://cve.report/api/cve/CVE-2021-27208.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-27208","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-27208"},"summary":{"title":"CVE-2021-27208","description":"When booting a Zync-7000 SOC device from nand flash memory, the nand driver in the ROM does not validate the inputs when reading in any parameters in the nand’s parameter page. IF a field read in from the parameter page is too large, this causes a buffer overflow that could lead to arbitrary code execution. Physical access and modification of the board assembly on which the Zynq-7000 SoC device mounted is needed to replace the original NAND flash memory with a NAND flash emulation device for this attack to be successful.","state":"PUBLIC","assigner":"cve@mitre.org","published_at":"2021-03-15 13:15:00","updated_at":"2021-03-30 12:52:00"},"problem_types":["CWE-120"],"metrics":[],"references":[{"url":"http://www.onfi.org/specifications","name":"http://www.onfi.org/specifications","refsource":"MISC","tags":["Not Applicable"],"title":"Specifications - ONFI","mime":"text/html","httpstatus":"200","archivestatus":"0"},{"url":"https://www.xilinx.com/products/silicon-devices/soc/zynq-7000.html","name":"https://www.xilinx.com/products/silicon-devices/soc/zynq-7000.html","refsource":"MISC","tags":["Product","Vendor Advisory"],"title":"Zynq-7000 All Programmable SoC","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.xilinx.com/support/answers/76201.html","name":"https://www.xilinx.com/support/answers/76201.html","refsource":"MISC","tags":["Vendor Advisory"],"title":"AR# 76201: Design Advisory for Zynq-7000 SoC: Buffer Overflow in the BootROM NAND Driver","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-27208","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-27208","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"27208","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"xilinx","cpe5":"zynq-7000","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"27208","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"xilinx","cpe5":"zynq-7000s","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"27208","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"xilinx","cpe5":"zynq-7000s_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"27208","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"xilinx","cpe5":"zynq-7000_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2021-27208","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"When booting a Zync-7000 SOC device from nand flash memory, the nand driver in the ROM does not validate the inputs when reading in any parameters in the nand’s parameter page. IF a field read in from the parameter page is too large, this causes a buffer overflow that could lead to arbitrary code execution. Physical access and modification of the board assembly on which the Zynq-7000 SoC device mounted is needed to replace the original NAND flash memory with a NAND flash emulation device for this attack to be successful."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://www.xilinx.com/products/silicon-devices/soc/zynq-7000.html","url":"https://www.xilinx.com/products/silicon-devices/soc/zynq-7000.html"},{"refsource":"MISC","name":"https://www.xilinx.com/support/answers/76201.html","url":"https://www.xilinx.com/support/answers/76201.html"},{"refsource":"MISC","name":"http://www.onfi.org/specifications","url":"http://www.onfi.org/specifications"}]}},"nvd":{"publishedDate":"2021-03-15 13:15:00","lastModifiedDate":"2021-03-30 12:52:00","problem_types":["CWE-120"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"PHYSICAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":6.8,"baseSeverity":"MEDIUM"},"exploitabilityScore":0.9,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:P/I:P/A:P","accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":4.6},"severity":"MEDIUM","exploitabilityScore":3.9,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:xilinx:zynq-7000s_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:xilinx:zynq-7000s:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:xilinx:zynq-7000_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:xilinx:zynq-7000:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"27208","Ordinal":"202298","Title":"CVE-2021-27208","CVE":"CVE-2021-27208","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"27208","Ordinal":"1","NoteData":"When booting a Zync-7000 SOC device from nand flash memory, the nand driver in the ROM does not validate the inputs when reading in any parameters in the nand’s parameter page. IF a field read in from the parameter page is too large, this causes a buffer overflow that could lead to arbitrary code execution. Physical access and modification of the board assembly on which the Zynq-7000 SoC device mounted is needed to replace the original NAND flash memory with a NAND flash emulation device for this attack to be successful.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"27208","Ordinal":"2","NoteData":"2021-03-15","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"27208","Ordinal":"3","NoteData":"2021-03-24","Type":"Other","Title":"Modified"}]}}}