{"api_version":"1","generated_at":"2026-04-23T07:01:05+00:00","cve":"CVE-2021-28643","urls":{"html":"https://cve.report/CVE-2021-28643","api":"https://cve.report/api/cve/CVE-2021-28643.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-28643","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-28643"},"summary":{"title":"CVE-2021-28643","description":"Acrobat Reader DC versions 2021.005.20054 (and earlier), 2020.004.30005 (and earlier) and 2017.011.30197 (and earlier) are affected by a Type Confusion vulnerability. An unauthenticated attacker could leverage this vulnerability to disclose sensitive memory information in the context of the current user. Exploitation of this issue requires user interaction in that a victim must open a malicious file.","state":"PUBLIC","assigner":"psirt@adobe.com","published_at":"2021-08-20 19:15:00","updated_at":"2021-08-26 23:55:00"},"problem_types":["CWE-843"],"metrics":[],"references":[{"url":"https://helpx.adobe.com/security/products/acrobat/apsb21-51.html","name":"https://helpx.adobe.com/security/products/acrobat/apsb21-51.html","refsource":"MISC","tags":[],"title":"Adobe Security Bulletin","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-28643","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-28643","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"28643","vulnerable":"1","versionEndIncluding":"17.011.30197","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"adobe","cpe5":"acrobat_dc","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"classic","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"28643","vulnerable":"1","versionEndIncluding":"20.004.30005","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"adobe","cpe5":"acrobat_dc","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"classic","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"28643","vulnerable":"1","versionEndIncluding":"21.005.20054","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"adobe","cpe5":"acrobat_dc","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"continuous","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"28643","vulnerable":"1","versionEndIncluding":"17.011.30197","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"adobe","cpe5":"acrobat_reader_dc","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"classic","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"28643","vulnerable":"1","versionEndIncluding":"20.004.30005","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"adobe","cpe5":"acrobat_reader_dc","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"classic","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"28643","vulnerable":"1","versionEndIncluding":"21.005.20054","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"adobe","cpe5":"acrobat_reader_dc","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"continuous","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2021-28643","qid":"375700","title":"Adobe Security Update for Adobe Acrobat and Adobe Reader (APSB21-51)"}]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"psirt@adobe.com","DATE_PUBLIC":"2021-07-13T23:00:00.000Z","ID":"CVE-2021-28643","STATE":"PUBLIC","TITLE":"Adobe Acrobat Pro DC embedDocAsDataObject Type Confusion Information Disclosure Vulnerability"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Acrobat Reader","version":{"version_data":[{"version_affected":"<=","version_value":"2020.004.30005"},{"version_affected":"<=","version_value":"2017.011.30197"},{"version_affected":"<=","version_value":"2021.005.20054"},{"version_affected":"<=","version_value":"None"}]}}]},"vendor_name":"Adobe"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Acrobat Reader DC versions 2021.005.20054 (and earlier), 2020.004.30005 (and earlier) and 2017.011.30197 (and earlier) are affected by a Type Confusion vulnerability. An unauthenticated attacker could leverage this vulnerability to disclose sensitive memory information in the context of the current user. Exploitation of this issue requires user interaction in that a victim must open a malicious file."}]},"impact":{"cvss":{"attackComplexity":"Low","attackVector":"Local","availabilityImpact":"None","baseScore":3.3,"baseSeverity":"Low","confidentialityImpact":"Low","integrityImpact":"None","privilegesRequired":"None","scope":"Unchanged","userInteraction":"Required","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Access of Resource Using Incompatible Type ('Type Confusion') (CWE-843)"}]}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://helpx.adobe.com/security/products/acrobat/apsb21-51.html","name":"https://helpx.adobe.com/security/products/acrobat/apsb21-51.html"}]},"source":{"discovery":"EXTERNAL"}},"nvd":{"publishedDate":"2021-08-20 19:15:00","lastModifiedDate":"2021-08-26 23:55:00","problem_types":["CWE-843"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":3.3,"baseSeverity":"LOW"},"exploitabilityScore":1.8,"impactScore":1.4},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:N/A:N","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":4.3},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:adobe:acrobat_reader_dc:*:*:*:*:classic:*:*:*","versionStartIncluding":"17.011.30059","versionEndIncluding":"17.011.30197","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:adobe:acrobat_dc:*:*:*:*:classic:*:*:*","versionStartIncluding":"17.011.30059","versionEndIncluding":"17.011.30197","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:adobe:acrobat_dc:*:*:*:*:continuous:*:*:*","versionStartIncluding":"15.008.20082","versionEndIncluding":"21.005.20054","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:adobe:acrobat_dc:*:*:*:*:classic:*:*:*","versionStartIncluding":"20.001.30005","versionEndIncluding":"20.004.30005","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:adobe:acrobat_reader_dc:*:*:*:*:continuous:*:*:*","versionStartIncluding":"15.008.20082","versionEndIncluding":"21.005.20054","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:adobe:acrobat_reader_dc:*:*:*:*:classic:*:*:*","versionStartIncluding":"20.001.30005","versionEndIncluding":"20.004.30005","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"28643","Ordinal":"203814","Title":"CVE-2021-28643","CVE":"CVE-2021-28643","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"28643","Ordinal":"1","NoteData":"Acrobat Reader DC versions 2021.005.20054 (and earlier), 2020.004.30005 (and earlier) and 2017.011.30197 (and earlier) are affected by a Type Confusion vulnerability. An unauthenticated attacker could leverage this vulnerability to disclose sensitive memory information in the context of the current user. Exploitation of this issue requires user interaction in that a victim must open a malicious file.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"28643","Ordinal":"2","NoteData":"2021-08-20","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"28643","Ordinal":"3","NoteData":"2021-08-20","Type":"Other","Title":"Modified"}]}}}