{"api_version":"1","generated_at":"2026-05-04T08:41:04+00:00","cve":"CVE-2021-30127","urls":{"html":"https://cve.report/CVE-2021-30127","api":"https://cve.report/api/cve/CVE-2021-30127.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-30127","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-30127"},"summary":{"title":"CVE-2021-30127","description":"TerraMaster F2-210 devices through 2021-04-03 use UPnP to make the admin web server accessible over the Internet on TCP port 8181, which is arguably inconsistent with the \"It is only available on the local network\" documentation. NOTE: manually editing /etc/upnp.json provides a partial but undocumented workaround.","state":"PUBLIC","assigner":"cve@mitre.org","published_at":"2021-04-03 18:15:00","updated_at":"2022-07-12 17:42:00"},"problem_types":["NVD-CWE-Other"],"metrics":[],"references":[{"url":"https://kn100.me/terramaster-nas-exposing-itself-over-upnp/","name":"https://kn100.me/terramaster-nas-exposing-itself-over-upnp/","refsource":"MISC","tags":[],"title":"Terramaster NAS exposing itself with UPNP","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://news.ycombinator.com/item?id=26681984","name":"https://news.ycombinator.com/item?id=26681984","refsource":"MISC","tags":[],"title":"My NAS exposes itself over the internet without permission | Hacker News","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-30127","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-30127","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"30127","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"terra-master","cpe5":"f2-210","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"30127","vulnerable":"1","versionEndIncluding":"2021-04-03","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"terra-master","cpe5":"f2-210_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2021-30127","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"TerraMaster F2-210 devices through 2021-04-03 use UPnP to make the admin web server accessible over the Internet on TCP port 8181, which is arguably inconsistent with the \"It is only available on the local network\" documentation. NOTE: manually editing /etc/upnp.json provides a partial but undocumented workaround."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"url":"https://kn100.me/terramaster-nas-exposing-itself-over-upnp/","refsource":"MISC","name":"https://kn100.me/terramaster-nas-exposing-itself-over-upnp/"},{"url":"https://news.ycombinator.com/item?id=26681984","refsource":"MISC","name":"https://news.ycombinator.com/item?id=26681984"}]}},"nvd":{"publishedDate":"2021-04-03 18:15:00","lastModifiedDate":"2022-07-12 17:42:00","problem_types":["NVD-CWE-Other"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"LOW","baseScore":7.3,"baseSeverity":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.4},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":7.5},"severity":"HIGH","exploitabilityScore":10,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:terra-master:f2-210_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2021-04-03","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:terra-master:f2-210:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"30127","Ordinal":"205358","Title":"CVE-2021-30127","CVE":"CVE-2021-30127","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"30127","Ordinal":"1","NoteData":"TerraMaster F2-210 devices through 2021-04-03 use UPnP to make the admin web server accessible over the Internet on TCP port 8181, which is arguably inconsistent with the \"It is only available on the local network\" documentation. NOTE: manually editing /etc/upnp.json provides a partial but undocumented workaround.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"30127","Ordinal":"2","NoteData":"2021-04-03","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"30127","Ordinal":"3","NoteData":"2021-04-03","Type":"Other","Title":"Modified"}]}}}