{"api_version":"1","generated_at":"2026-04-23T02:18:54+00:00","cve":"CVE-2021-32025","urls":{"html":"https://cve.report/CVE-2021-32025","api":"https://cve.report/api/cve/CVE-2021-32025.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-32025","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-32025"},"summary":{"title":"CVE-2021-32025","description":"An elevation of privilege vulnerability in the QNX Neutrino Kernel of affected versions of QNX Software Development Platform version(s) 6.4.0 to 7.0, QNX Momentics all 6.3.x versions, QNX OS for Safety versions 1.0.0 to 1.0.2, QNX OS for Safety versions 2.0.0 to 2.0.1, QNX for Medical versions 1.0.0 to 1.1.1, and QNX OS for Medical version 2.0.0 could allow an attacker to potentially access data, modify behavior, or permanently crash the system.","state":"PUBLIC","assigner":"secure@blackberry.com","published_at":"2022-03-10 17:42:00","updated_at":"2022-07-12 17:42:00"},"problem_types":["NVD-CWE-noinfo"],"metrics":[],"references":[{"url":"http://support.blackberry.com/kb/articleDetail?articleNumber=000090868","name":"http://support.blackberry.com/kb/articleDetail?articleNumber=000090868","refsource":"MISC","tags":[],"title":"QNX-2022-001 Vulnerability in QNX Neutrino Kernel Impacts QNX Software Development Platform (SDP), QNX OS for Medical, and QNX OS for Safety","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-32025","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-32025","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"32025","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"blackberry","cpe5":"qnx_momentics","cpe6":"6.3.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"32025","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"blackberry","cpe5":"qnx_momentics","cpe6":"6.3.2","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"32025","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"blackberry","cpe5":"qnx_os_for_medical","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"32025","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"blackberry","cpe5":"qnx_os_for_medical","cpe6":"2.0.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"32025","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"blackberry","cpe5":"qnx_os_for_safety","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"32025","vulnerable":"1","versionEndIncluding":"7.0","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"blackberry","cpe5":"qnx_software_development_platform","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2021-32025","ASSIGNER":"secure@blackberry.com","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"QNX Software Development Platform (SDP), QNX OS for Medical (QOSM), and QNX OS for Safety (QOS)","version":{"version_data":[{"version_value":"QNX SDP 6.4.0 to 7.0"},{"version_value":"QNX Momentics all 6.3.x versions"},{"version_value":"QNX OS for Safety versions 1.0.0 to 1.0.2 safety products compliant with IEC 61508 and/or ISO 26262"},{"version_value":"QNX OS for Safety versions 2.0.0 to 2.0.1 safety products compliant with IEC 61508 and/or ISO 26262"},{"version_value":"QNX OS for Medical versions 1.0.0 to 1.1.1 safety products compliant with IEC 62304"},{"version_value":"QNX OS for Medical versions 2.0.0 safety product compliant with IEC 62304"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Elevation of privilege"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"http://support.blackberry.com/kb/articleDetail?articleNumber=000090868","url":"http://support.blackberry.com/kb/articleDetail?articleNumber=000090868"}]},"description":{"description_data":[{"lang":"eng","value":"An elevation of privilege vulnerability in the QNX Neutrino Kernel of affected versions of QNX Software Development Platform version(s) 6.4.0 to 7.0, QNX Momentics all 6.3.x versions, QNX OS for Safety versions 1.0.0 to 1.0.2, QNX OS for Safety versions 2.0.0 to 2.0.1, QNX for Medical versions 1.0.0 to 1.1.1, and QNX OS for Medical version 2.0.0 could allow an attacker to potentially access data, modify behavior, or permanently crash the system."}]}},"nvd":{"publishedDate":"2022-03-10 17:42:00","lastModifiedDate":"2022-07-12 17:42:00","problem_types":["NVD-CWE-noinfo"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:C/I:C/A:C","accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE","baseScore":7.2},"severity":"HIGH","exploitabilityScore":3.9,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:blackberry:qnx_software_development_platform:*:*:*:*:*:*:*:*","versionStartIncluding":"6.4.0","versionEndIncluding":"7.0","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:blackberry:qnx_os_for_medical:2.0.0:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:blackberry:qnx_os_for_medical:*:*:*:*:*:*:*:*","versionStartIncluding":"1.0","versionEndExcluding":"1.1.2","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:blackberry:qnx_os_for_safety:*:*:*:*:*:*:*:*","versionStartIncluding":"2.0.0","versionEndExcluding":"2.0.2","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:blackberry:qnx_os_for_safety:*:*:*:*:*:*:*:*","versionStartIncluding":"1.0.0","versionEndExcluding":"1.0.3","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:blackberry:qnx_momentics:6.3.0:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:blackberry:qnx_momentics:6.3.2:*:*:*:*:*:*:*","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"32025","Ordinal":"207354","Title":"CVE-2021-32025","CVE":"CVE-2021-32025","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"32025","Ordinal":"1","NoteData":"** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided.","Type":"Description","Title":null}]}}}