{"api_version":"1","generated_at":"2026-07-24T01:47:57+00:00","cve":"CVE-2021-32948","urls":{"html":"https://cve.report/CVE-2021-32948","api":"https://cve.report/api/cve/CVE-2021-32948.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-32948","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-32948"},"summary":{"title":"CVE-2021-32948","description":"An out-of-bounds write issue exists in the DWG file-reading procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2021-06-17 13:15:00","updated_at":"2023-02-14 12:15:00"},"problem_types":["CWE-787"],"metrics":[],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-21-984/","name":"https://www.zerodayinitiative.com/advisories/ZDI-21-984/","refsource":"MISC","tags":[],"title":"ZDI-21-984 | Zero Day Initiative","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf","refsource":"CONFIRM","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf","refsource":"CONFIRM","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"200"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf","refsource":"CONFIRM","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02","name":"https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02","refsource":"MISC","tags":[],"title":"Open Design Alliance Drawings SDK | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-32948","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-32948","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"32948","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"opendesign","cpe5":"drawings_sdk","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"32948","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"comos","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"32948","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"jt2go","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"32948","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"teamcenter_visualization","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2021-32948","ASSIGNER":"ics-cert@hq.dhs.gov","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"Drawings SDK","version":{"version_data":[{"version_value":"All versions prior to 2022.4"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"OUT-OF-BOUNDS WRITE CWE-787"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02","url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02"},{"refsource":"CONFIRM","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf"},{"refsource":"MISC","name":"https://www.zerodayinitiative.com/advisories/ZDI-21-984/","url":"https://www.zerodayinitiative.com/advisories/ZDI-21-984/"},{"refsource":"CONFIRM","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf"},{"refsource":"CONFIRM","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"}]},"description":{"description_data":[{"lang":"eng","value":"An out-of-bounds write issue exists in the DWG file-reading procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process."}]}},"nvd":{"publishedDate":"2021-06-17 13:15:00","lastModifiedDate":"2023-02-14 12:15:00","problem_types":["CWE-787"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":6.8},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:opendesign:drawings_sdk:*:*:*:*:*:*:*:*","versionEndExcluding":"2022.4","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*","versionEndExcluding":"13.2.0.1","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*","versionEndExcluding":"13.2.0.1","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:comos:*:*:*:*:*:*:*:*","versionEndExcluding":"10.4.1","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"32948","Ordinal":"208338","Title":"CVE-2021-32948","CVE":"CVE-2021-32948","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"32948","Ordinal":"1","NoteData":"An out-of-bounds write issue exists in the DWG file-reading procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"32948","Ordinal":"2","NoteData":"2021-06-17","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"32948","Ordinal":"3","NoteData":"2021-08-18","Type":"Other","Title":"Modified"}]}}}