{"api_version":"1","generated_at":"2026-06-29T19:04:17+00:00","cve":"CVE-2021-33000","urls":{"html":"https://cve.report/CVE-2021-33000","api":"https://cve.report/api/cve/CVE-2021-33000.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-33000","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-33000"},"summary":{"title":"CVE-2021-33000","description":"Parsing a maliciously crafted project file may cause a heap-based buffer overflow, which may allow an attacker to perform arbitrary code execution. User interaction is required on the WebAccess HMI Designer (versions 2.1.9.95 and prior).","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2021-06-24 18:15:00","updated_at":"2021-07-01 14:23:00"},"problem_types":["CWE-787"],"metrics":[],"references":[{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-173-01","name":"https://us-cert.cisa.gov/ics/advisories/icsa-21-173-01","refsource":"MISC","tags":[],"title":"Advantech WebAccess HMI Designer (Update A) | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-33000","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-33000","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"33000","vulnerable":"1","versionEndIncluding":"2.1.9.95","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"advantech","cpe5":"webaccess\\/hmi_designer","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33000","vulnerable":"1","versionEndIncluding":"2.1.9.95","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"advantech","cpe5":"webaccess_hmi_designer","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2021-33000","qid":"590684","title":"Advantech WebAccess HMI Designer Multiple Vulnerabilities (ICSA-21-173-01)"}]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2021-33000","ASSIGNER":"ics-cert@hq.dhs.gov","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"WebAccess HMI Designer","version":{"version_data":[{"version_value":"versions 2.1.9.95 and prior"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"HEAP-BASED BUFFER OVERFLOW CWE-122"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://us-cert.cisa.gov/ics/advisories/icsa-21-173-01","url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-173-01"}]},"description":{"description_data":[{"lang":"eng","value":"Parsing a maliciously crafted project file may cause a heap-based buffer overflow, which may allow an attacker to perform arbitrary code execution. User interaction is required on the WebAccess HMI Designer (versions 2.1.9.95 and prior)."}]}},"nvd":{"publishedDate":"2021-06-24 18:15:00","lastModifiedDate":"2021-07-01 14:23:00","problem_types":["CWE-787"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":6.8},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:advantech:webaccess\\/hmi_designer:*:*:*:*:*:*:*:*","versionEndIncluding":"2.1.9.95","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"33000","Ordinal":"208390","Title":"CVE-2021-33000","CVE":"CVE-2021-33000","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"33000","Ordinal":"1","NoteData":"Parsing a maliciously crafted project file may cause a heap-based buffer overflow, which may allow an attacker to perform arbitrary code execution. User interaction is required on the WebAccess HMI Designer (versions 2.1.9.95 and prior).","Type":"Description","Title":null},{"CveYear":"2021","CveId":"33000","Ordinal":"2","NoteData":"2021-06-24","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"33000","Ordinal":"3","NoteData":"2021-06-24","Type":"Other","Title":"Modified"}]}}}