{"api_version":"1","generated_at":"2026-06-29T21:50:53+00:00","cve":"CVE-2021-33004","urls":{"html":"https://cve.report/CVE-2021-33004","api":"https://cve.report/api/cve/CVE-2021-33004.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-33004","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-33004"},"summary":{"title":"CVE-2021-33004","description":"The affected product is vulnerable to memory corruption condition due to lack of proper validation of user supplied files, which may allow an attacker to execute arbitrary code. User interaction is required on the WebAccess HMI Designer (versions 2.1.9.95 and prior).","state":"PUBLIC","assigner":"ics-cert@hq.dhs.gov","published_at":"2021-06-24 18:15:00","updated_at":"2022-07-02 18:15:00"},"problem_types":["CWE-787"],"metrics":[],"references":[{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-173-01","name":"https://us-cert.cisa.gov/ics/advisories/icsa-21-173-01","refsource":"MISC","tags":[],"title":"Advantech WebAccess HMI Designer (Update A) | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-33004","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-33004","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"33004","vulnerable":"1","versionEndIncluding":"2.1.9.95","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"advantech","cpe5":"webaccess\\/hmi_designer","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2021-33004","qid":"590684","title":"Advantech WebAccess HMI Designer Multiple Vulnerabilities (ICSA-21-173-01)"}]},"source_records":{"cve_program":{"data_type":"CVE","data_format":"MITRE","data_version":"4.0","CVE_data_meta":{"ID":"CVE-2021-33004","ASSIGNER":"ics-cert@hq.dhs.gov","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"vendor_name":"n/a","product":{"product_data":[{"product_name":"WebAccess HMI Designer","version":{"version_data":[{"version_value":"versions 2.1.9.95 and prior"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"IMPROPER RESTRICTION OF OPERATION WITHIN THE BOUNDS OF A MEMORY BUFFER CWE-119"}]}]},"references":{"reference_data":[{"refsource":"MISC","name":"https://us-cert.cisa.gov/ics/advisories/icsa-21-173-01","url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-173-01"}]},"description":{"description_data":[{"lang":"eng","value":"The affected product is vulnerable to memory corruption condition due to lack of proper validation of user supplied files, which may allow an attacker to execute arbitrary code. User interaction is required on the WebAccess HMI Designer (versions 2.1.9.95 and prior)."}]}},"nvd":{"publishedDate":"2021-06-24 18:15:00","lastModifiedDate":"2022-07-02 18:15:00","problem_types":["CWE-787"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":6.8},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:advantech:webaccess\\/hmi_designer:*:*:*:*:*:*:*:*","versionEndIncluding":"2.1.9.95","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"33004","Ordinal":"208394","Title":"CVE-2021-33004","CVE":"CVE-2021-33004","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"33004","Ordinal":"1","NoteData":"The affected product is vulnerable to memory corruption condition due to lack of proper validation of user supplied files, which may allow an attacker to execute arbitrary code. User interaction is required on the WebAccess HMI Designer (versions 2.1.9.95 and prior).","Type":"Description","Title":null},{"CveYear":"2021","CveId":"33004","Ordinal":"2","NoteData":"2021-06-24","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"33004","Ordinal":"3","NoteData":"2021-06-24","Type":"Other","Title":"Modified"}]}}}