{"api_version":"1","generated_at":"2026-06-13T19:07:59+00:00","cve":"CVE-2021-33012","urls":{"html":"https://cve.report/CVE-2021-33012","api":"https://cve.report/api/cve/CVE-2021-33012.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-33012","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-33012"},"summary":{"title":"CVE-2021-33012","description":"Rockwell Automation MicroLogix 1100, all versions, allows a remote, unauthenticated attacker sending specially crafted commands to cause the PLC to fault when the controller is switched to RUN mode, which results in a denial-of-service condition. If successfully exploited, this vulnerability will cause the controller to fault whenever the controller is switched to RUN mode.","state":"PUBLISHED","assigner":"icscert","published_at":"2021-07-09 15:15:08","updated_at":"2026-06-03 14:16:24"},"problem_types":["CWE-20","NVD-CWE-noinfo","CWE-20 IMPROPER INPUT VALIDATION CWE-20"],"metrics":[{"version":"3.1","source":"nvd@nist.gov","type":"Primary","score":"8.6","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H","baseScore":8.6,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"}},{"version":"3.1","source":"ADP","type":"DECLARED","score":"7.5","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","data":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"}},{"version":"3.1","source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","score":"7.5","severity":"HIGH","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","data":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"}},{"version":"2.0","source":"nvd@nist.gov","type":"Primary","score":"5","severity":"","vector":"AV:N/AC:L/Au:N/C:N/I:N/A:P","data":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:P","baseScore":5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL"}}],"references":[{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-189-01","name":"https://us-cert.cisa.gov/ics/advisories/icsa-21-189-01","refsource":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"],"title":"Rockwell Automation MicroLogix 1100 | CISA","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-33012","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-33012","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[{"source":"CNA","vendor":"n/a","product":"Rockwell Automation MicroLogix 1100","version":"affected All Versions","platforms":[]}],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"33012","vulnerable":"0","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"rockwellautomation","cpe5":"micrologix_1100","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33012","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"rockwellautomation","cpe5":"micrologix_1100_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":{"cve_year":"2021","cve_id":"33012","cve":"CVE-2021-33012","epss":"0.035470000","percentile":"0.879210000","score_date":"2026-06-08","updated_at":"2026-06-09 00:12:52"},"legacy_qids":[{"cve":"CVE-2021-33012","qid":"590749","title":"Rockwell Automation MicroLogix 1100 Vulnerability (ICSA-21-189-01)"}]},"source_records":{"cve_program":{"containers":{"adp":[{"providerMetadata":{"dateUpdated":"2024-08-03T23:42:19.616Z","orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE"},"references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-189-01"}],"title":"CVE Program Container"},{"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"}},{"other":{"content":{"id":"CVE-2021-33012","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-06-03T13:17:35.412176Z","version":"2.0.3"},"type":"ssvc"}}],"providerMetadata":{"dateUpdated":"2026-06-03T13:18:00.338Z","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP"},"title":"CISA ADP Vulnrichment"}],"cna":{"affected":[{"product":"Rockwell Automation MicroLogix 1100","vendor":"n/a","versions":[{"status":"affected","version":"All Versions"}]}],"descriptions":[{"lang":"en","value":"Rockwell Automation MicroLogix 1100, all versions, allows a remote, unauthenticated attacker sending specially crafted commands to cause the PLC to fault when the controller is switched to RUN mode, which results in a denial-of-service condition. If successfully exploited, this vulnerability will cause the controller to fault whenever the controller is switched to RUN mode."}],"problemTypes":[{"descriptions":[{"cweId":"CWE-20","description":"IMPROPER INPUT VALIDATION CWE-20","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2021-07-09T14:03:55.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"tags":["x_refsource_MISC"],"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-189-01"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2021-33012","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Rockwell Automation MicroLogix 1100","version":{"version_data":[{"version_value":"All Versions"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Rockwell Automation MicroLogix 1100, all versions, allows a remote, unauthenticated attacker sending specially crafted commands to cause the PLC to fault when the controller is switched to RUN mode, which results in a denial-of-service condition. If successfully exploited, this vulnerability will cause the controller to fault whenever the controller is switched to RUN mode."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"IMPROPER INPUT VALIDATION CWE-20"}]}]},"references":{"reference_data":[{"name":"https://us-cert.cisa.gov/ics/advisories/icsa-21-189-01","refsource":"MISC","url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-189-01"}]}}}},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2021-33012","datePublished":"2021-07-09T14:03:55.000Z","dateReserved":"2021-05-13T00:00:00.000Z","dateUpdated":"2026-06-03T13:18:00.338Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"},"nvd":{"publishedDate":"2021-07-09 15:15:08","lastModifiedDate":"2026-06-03 14:16:24","problem_types":["CWE-20","NVD-CWE-noinfo","CWE-20 IMPROPER INPUT VALIDATION CWE-20"],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H","baseScore":8.6,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":4},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:P","baseScore":5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":10,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:micrologix_1100_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"D5252A0C-A923-4BA0-A857-9BF21F8BF79B"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:rockwellautomation:micrologix_1100:-:*:*:*:*:*:*:*","matchCriteriaId":"DA42C7F4-EEC1-44D2-BD46-237969FF6E1A"}]}]}]},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"33012","Ordinal":"1","Title":"CVE-2021-33012","CVE":"CVE-2021-33012","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"33012","Ordinal":"1","NoteData":"Rockwell Automation MicroLogix 1100, all versions, allows a remote, unauthenticated attacker sending specially crafted commands to cause the PLC to fault when the controller is switched to RUN mode, which results in a denial-of-service condition. If successfully exploited, this vulnerability will cause the controller to fault whenever the controller is switched to RUN mode.","Type":"Description","Title":"CVE-2021-33012"},{"CveYear":"2021","CveId":"33012","Ordinal":"2","NoteData":"2021-07-09","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"33012","Ordinal":"3","NoteData":"2021-07-09","Type":"Other","Title":"Modified"}]}}}