{"api_version":"1","generated_at":"2026-04-23T18:36:44+00:00","cve":"CVE-2021-33270","urls":{"html":"https://cve.report/CVE-2021-33270","api":"https://cve.report/api/cve/CVE-2021-33270.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-33270","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-33270"},"summary":{"title":"CVE-2021-33270","description":"D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_800462c4 in /formAdvFirewall. This vulnerability is triggered via a crafted POST request.","state":"PUBLIC","assigner":"cve@mitre.org","published_at":"2021-12-01 22:15:00","updated_at":"2021-12-03 14:01:00"},"problem_types":["CWE-787"],"metrics":[],"references":[{"url":"https://www.dlink.com/en/security-bulletin/","name":"https://www.dlink.com/en/security-bulletin/","refsource":"MISC","tags":[],"title":"Security Bulletin | D-Link","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln06","name":"https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln06","refsource":"MISC","tags":[],"title":"IoT-poc/D-Link-DIR809/vuln06 at master · Lnkvct/IoT-poc · GitHub","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-33270","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-33270","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"33270","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"dlink","cpe5":"dir-809","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33270","vulnerable":"1","versionEndIncluding":"1.12wwb03","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"dlink","cpe5":"dir-809_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2021-33270","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_800462c4 in /formAdvFirewall. This vulnerability is triggered via a crafted POST request."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"url":"https://www.dlink.com/en/security-bulletin/","refsource":"MISC","name":"https://www.dlink.com/en/security-bulletin/"},{"url":"https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln06","refsource":"MISC","name":"https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln06"}]}},"nvd":{"publishedDate":"2021-12-01 22:15:00","lastModifiedDate":"2021-12-03 14:01:00","problem_types":["CWE-787"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL"},"exploitabilityScore":3.9,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE","baseScore":10},"severity":"HIGH","exploitabilityScore":10,"impactScore":10,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:dlink:dir-809_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"1.12wwb03","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:dlink:dir-809:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"33270","Ordinal":"208672","Title":"CVE-2021-33270","CVE":"CVE-2021-33270","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"33270","Ordinal":"1","NoteData":"D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_800462c4 in /formAdvFirewall. This vulnerability is triggered via a crafted POST request.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"33270","Ordinal":"2","NoteData":"2021-12-01","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"33270","Ordinal":"3","NoteData":"2021-12-01","Type":"Other","Title":"Modified"}]}}}