{"api_version":"1","generated_at":"2026-04-21T14:07:31+00:00","cve":"CVE-2021-33626","urls":{"html":"https://cve.report/CVE-2021-33626","api":"https://cve.report/api/cve/CVE-2021-33626.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-33626","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-33626"},"summary":{"title":"CVE-2021-33626","description":"A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution.","state":"PUBLIC","assigner":"cve@mitre.org","published_at":"2021-10-01 03:15:00","updated_at":"2022-04-24 02:03:00"},"problem_types":["CWE-829"],"metrics":[],"references":[{"url":"https://www.insyde.com/security-pledge/SA-2021001","name":"https://www.insyde.com/security-pledge/SA-2021001","refsource":"MISC","tags":[],"title":"Security Advisory | Insyde Software","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://www.insyde.com/security-pledge","name":"https://www.insyde.com/security-pledge","refsource":"MISC","tags":[],"title":"Insyde's Security Pledge | Insyde Software","mime":"text/html","httpstatus":"200","archivestatus":"200"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf","refsource":"CONFIRM","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"200"},{"url":"https://security.netapp.com/advisory/ntap-20220216-0006/","name":"https://security.netapp.com/advisory/ntap-20220216-0006/","refsource":"CONFIRM","tags":[],"title":"CVE-2021-33626 InsydeH2O Vulnerability in NetApp Products | NetApp Product Security","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-33626","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-33626","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"33626","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"insyde","cpe5":"insydeh2o","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"ruggedcom_apr1808","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"ruggedcom_apr1808_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simatic_field_pg_m5","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simatic_field_pg_m5_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simatic_field_pg_m6","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simatic_field_pg_m6_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simatic_ipc127e","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simatic_ipc127e_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simatic_ipc227g","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simatic_ipc227g_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simatic_ipc277g","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simatic_ipc277g_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simatic_ipc327g","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simatic_ipc327g_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simatic_ipc377g","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simatic_ipc377g_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simatic_ipc427e","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simatic_ipc427e_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simatic_ipc477e","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simatic_ipc477e_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simatic_ipc477e_pro","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simatic_ipc477e_pro_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simatic_ipc627e","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simatic_ipc627e_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simatic_ipc647e","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simatic_ipc647e_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simatic_ipc677e","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simatic_ipc677e_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simatic_ipc847e","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simatic_ipc847e_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"siemens","cpe5":"simatic_itp1000","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"33626","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"siemens","cpe5":"simatic_itp1000_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2021-33626","qid":"590981","title":"Siemens Industrial Products Insyde BIOS Multiple Vulnerabilities (SSA-306654)"}]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2021-33626","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"url":"https://www.insyde.com/security-pledge","refsource":"MISC","name":"https://www.insyde.com/security-pledge"},{"refsource":"MISC","name":"https://www.insyde.com/security-pledge/SA-2021001","url":"https://www.insyde.com/security-pledge/SA-2021001"},{"refsource":"CONFIRM","name":"https://security.netapp.com/advisory/ntap-20220216-0006/","url":"https://security.netapp.com/advisory/ntap-20220216-0006/"},{"refsource":"CONFIRM","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"}]},"source":{"discovery":"INTERNAL"}},"nvd":{"publishedDate":"2021-10-01 03:15:00","lastModifiedDate":"2022-04-24 02:03:00","problem_types":["CWE-829"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:P/I:P/A:P","accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":4.6},"severity":"MEDIUM","exploitabilityScore":3.9,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*","versionStartIncluding":"5.3","versionEndExcluding":"5.34.44","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*","versionStartIncluding":"5.2","versionEndExcluding":"5.25.44","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*","versionStartIncluding":"5.1","versionEndExcluding":"5.16.25","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*","versionStartIncluding":"5.4","versionEndExcluding":"5.42.44","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*","versionStartIncluding":"5.3","versionEndExcluding":"5.35.25","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*","versionStartIncluding":"5.2","versionEndExcluding":"5.26.25","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*","versionStartIncluding":"5.4","versionEndExcluding":"5.43.25","cpe_name":[]}]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:ruggedcom_apr1808_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:ruggedcom_apr1808:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simatic_field_pg_m6_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simatic_field_pg_m6:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simatic_ipc127e_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simatic_ipc127e:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simatic_ipc227g_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simatic_ipc227g:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simatic_ipc277g_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simatic_ipc277g:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simatic_ipc327g_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simatic_ipc327g:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simatic_ipc377g_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simatic_ipc377g:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simatic_ipc427e_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simatic_ipc477e_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simatic_ipc477e_pro_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simatic_ipc477e_pro:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simatic_ipc627e_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simatic_ipc627e:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simatic_ipc647e_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simatic_ipc677e_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simatic_ipc677e:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simatic_ipc847e_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:siemens:simatic_itp1000_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"33626","Ordinal":"209037","Title":"CVE-2021-33626","CVE":"CVE-2021-33626","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"33626","Ordinal":"1","NoteData":"A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"33626","Ordinal":"2","NoteData":"2021-09-30","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"33626","Ordinal":"3","NoteData":"2022-02-02","Type":"Other","Title":"Modified"}]}}}