{"api_version":"1","generated_at":"2026-07-23T20:58:47+00:00","cve":"CVE-2021-34332","urls":{"html":"https://cve.report/CVE-2021-34332","api":"https://cve.report/api/cve/CVE-2021-34332.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-34332","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-34332"},"summary":{"title":"CVE-2021-34332","description":"A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. A malformed input file could result in an infinite loop condition that leads to denial of service condition. An attacker could leverage this vulnerability to consume excessive resources. (CNVD-C-2021-79300)","state":"PUBLIC","assigner":"productcert@siemens.com","published_at":"2021-07-13 11:15:00","updated_at":"2021-07-15 18:08:00"},"problem_types":["CWE-835"],"metrics":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf","name":"N/A","refsource":"CONFIRM","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-34332","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-34332","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"34332","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"jt2go","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"34332","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"siemens","cpe5":"teamcenter_visualization","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2021-34332","qid":"590501","title":"Siemens JT2Go Multiple Vulnerabilities(ICSA-21-194-15)"}]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2021-34332","STATE":"PUBLIC"},"data_format":"MITRE","data_version":"4.0","data_type":"CVE","affects":{"vendor":{"vendor_data":[{"vendor_name":"Siemens","product":{"product_data":[{"product_name":"JT2Go","version":{"version_data":[{"version_value":"All versions < V13.2"}]}},{"product_name":"Teamcenter Visualization","version":{"version_data":[{"version_value":"All versions < V13.2"}]}}]}}]}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-835: Loop with Unreachable Exit Condition ('Infinite Loop')"}]}]},"description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. A malformed input file could result in an infinite loop condition that leads to denial of service condition. An attacker could leverage this vulnerability to consume excessive resources. (CNVD-C-2021-79300)"}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf","name":"https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf"}]}},"nvd":{"publishedDate":"2021-07-13 11:15:00","lastModifiedDate":"2021-07-15 18:08:00","problem_types":["CWE-835"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH","baseScore":5.5,"baseSeverity":"MEDIUM"},"exploitabilityScore":1.8,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:N/I:N/A:P","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL","baseScore":4.3},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*","versionEndExcluding":"13.2.0","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*","versionEndExcluding":"13.2.0","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"34332","Ordinal":"209779","Title":"CVE-2021-34332","CVE":"CVE-2021-34332","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"34332","Ordinal":"1","NoteData":"A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. A malformed input file could result in an infinite loop condition that leads to denial of service condition. An attacker could leverage this vulnerability to consume excessive resources. (CNVD-C-2021-79300)","Type":"Description","Title":null},{"CveYear":"2021","CveId":"34332","Ordinal":"2","NoteData":"2021-07-13","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"34332","Ordinal":"3","NoteData":"2021-07-13","Type":"Other","Title":"Modified"}]}}}