{"api_version":"1","generated_at":"2026-07-23T13:41:26+00:00","cve":"CVE-2021-34577","urls":{"html":"https://cve.report/CVE-2021-34577","api":"https://cve.report/api/cve/CVE-2021-34577.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-34577","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-34577"},"summary":{"title":"CVE-2021-34577","description":"In the Kaden PICOFLUX AiR water meter an adversary can read the values through wireless M-Bus mode 5 with a hardcoded shared key while being adjacent to the device.","state":"PUBLIC","assigner":"info@cert.vde.com","published_at":"2022-11-09 17:15:00","updated_at":"2022-11-15 16:57:00"},"problem_types":["CWE-798"],"metrics":[],"references":[{"url":"https://www.fit.vutbr.cz/~polcak/CVE-2021-34577","name":"https://www.fit.vutbr.cz/~polcak/CVE-2021-34577","refsource":"MISC","tags":[],"title":"","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-34577","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-34577","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"34577","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"kadenvodomery","cpe5":"picoflux_air","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"34577","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"kadenvodomery","cpe5":"picoflux_air_firmware","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"data_version":"4.0","data_type":"CVE","data_format":"MITRE","CVE_data_meta":{"ID":"CVE-2021-34577","ASSIGNER":"info@cert.vde.com","STATE":"PUBLIC"},"description":{"description_data":[{"lang":"eng","value":"In the Kaden PICOFLUX AiR water meter an adversary can read the values through wireless M-Bus mode 5 with a hardcoded shared key while being adjacent to the device."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-798 Use of Hard-coded Credentials","cweId":"CWE-798"}]}]},"affects":{"vendor":{"vendor_data":[{"vendor_name":"Kaden","product":{"product_data":[{"product_name":"PICOFLUX AiR","version":{"version_data":[{"version_value":"all","version_affected":"="}]}}]}}]}},"references":{"reference_data":[{"url":"https://www.fit.vutbr.cz/~polcak/CVE-2021-34577","refsource":"MISC","name":"https://www.fit.vutbr.cz/~polcak/CVE-2021-34577"}]},"generator":{"engine":"Vulnogram 0.1.0-dev"},"source":{"discovery":"EXTERNAL"},"credits":[{"lang":"en","value":"Libor POLČÁK reported to CERT@VDE"}],"impact":{"cvss":[{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"NONE","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"}]}},"nvd":{"publishedDate":"2022-11-09 17:15:00","lastModifiedDate":"2022-11-15 16:57:00","problem_types":["CWE-798"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE","baseScore":6.5,"baseSeverity":"MEDIUM"},"exploitabilityScore":2.8,"impactScore":3.6}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:kadenvodomery:picoflux_air_firmware:-:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:kadenvodomery:picoflux_air:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"34577","Ordinal":"210042","Title":"CVE-2021-34577","CVE":"CVE-2021-34577","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"34577","Ordinal":"1","NoteData":"** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided.","Type":"Description","Title":null}]}}}