{"api_version":"1","generated_at":"2026-07-24T22:41:08+00:00","cve":"CVE-2021-34593","urls":{"html":"https://cve.report/CVE-2021-34593","api":"https://cve.report/api/cve/CVE-2021-34593.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-34593","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-34593"},"summary":{"title":"CVE-2021-34593","description":"In CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56 unauthenticated crafted invalid requests may result in several denial-of-service conditions. Running PLC programs may be stopped, memory may be leaked, or further communication clients may be blocked from accessing the PLC.","state":"PUBLIC","assigner":"info@cert.vde.com","published_at":"2021-10-26 10:15:00","updated_at":"2022-04-12 18:05:00"},"problem_types":["CWE-755"],"metrics":[],"references":[{"url":"http://packetstormsecurity.com/files/165874/WAGO-750-8xxx-PLC-Denial-Of-Service-User-Enumeration.html","name":"http://packetstormsecurity.com/files/165874/WAGO-750-8xxx-PLC-Denial-Of-Service-User-Enumeration.html","refsource":"MISC","tags":[],"title":"WAGO 750-8xxx PLC Denial Of Service / User Enumeration ≈ Packet Storm","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=16877&token=8faab0fc1e069f4edfca5d5aba8146139f67a175&download=","name":"https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=16877&token=8faab0fc1e069f4edfca5d5aba8146139f67a175&download=","refsource":"CONFIRM","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"http://seclists.org/fulldisclosure/2021/Oct/64","name":"20211029 SEC Consult SA-20211028-0 :: Denial of Service in CODESYS V2","refsource":"FULLDISC","tags":[],"title":"Full Disclosure: SEC Consult SA-20211028-0 :: Denial of Service in CODESYS V2","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"http://packetstormsecurity.com/files/164716/CODESYS-2.4.7.0-Denial-Of-Service.html","name":"http://packetstormsecurity.com/files/164716/CODESYS-2.4.7.0-Denial-Of-Service.html","refsource":"MISC","tags":[],"title":"CODESYS 2.4.7.0 Denial Of Service ≈ Packet Storm","mime":"text/html","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-34593","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-34593","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"LEGACY","value":"This issue was discovered by Steffen Robertz and Gerhard Hechenberger from the SEC Consult Vulnerability Lab.","lang":""}],"nvd_cpes":[{"cve_year":"2021","cve_id":"34593","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"codesys","cpe5":"plcwinnt","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"34593","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"codesys","cpe5":"runtime_toolkit","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"34593","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"a","cpe4":"codesys","cpe5":"runtime_toolkit","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"x86","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"info@cert.vde.com","DATE_PUBLIC":"2021-10-25T14:00:00.000Z","ID":"CVE-2021-34593","STATE":"PUBLIC","TITLE":"CODESYS V2 runtime: unauthenticated invalid requests may result in denial-of-service"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"CODESYS V2 ","version":{"version_data":[{"version_affected":"<","version_name":"Runtime Toolkit 32 bit full","version_value":"V2.4.7.56"},{"version_affected":"<","version_name":"PLCWinNT","version_value":"V2.4.7.56"}]}}]},"vendor_name":"CODESYS"}]}},"credit":[{"lang":"eng","value":"This issue was discovered by Steffen Robertz and Gerhard Hechenberger from the SEC Consult Vulnerability Lab."}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"In CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56 unauthenticated crafted invalid requests may result in several denial-of-service conditions. Running PLC programs may be stopped, memory may be leaked, or further communication clients may be blocked from accessing the PLC."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-755 Improper Handling of Exceptional Conditions"}]}]},"references":{"reference_data":[{"name":"https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=16877&token=8faab0fc1e069f4edfca5d5aba8146139f67a175&download=","refsource":"CONFIRM","url":"https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=16877&token=8faab0fc1e069f4edfca5d5aba8146139f67a175&download="},{"refsource":"FULLDISC","name":"20211029 SEC Consult SA-20211028-0 :: Denial of Service in CODESYS V2","url":"http://seclists.org/fulldisclosure/2021/Oct/64"},{"refsource":"MISC","name":"http://packetstormsecurity.com/files/164716/CODESYS-2.4.7.0-Denial-Of-Service.html","url":"http://packetstormsecurity.com/files/164716/CODESYS-2.4.7.0-Denial-Of-Service.html"},{"refsource":"MISC","name":"http://packetstormsecurity.com/files/165874/WAGO-750-8xxx-PLC-Denial-Of-Service-User-Enumeration.html","url":"http://packetstormsecurity.com/files/165874/WAGO-750-8xxx-PLC-Denial-Of-Service-User-Enumeration.html"}]},"solution":[{"lang":"eng","value":"CODESYS GmbH has released the following product versions to solve the noted vulnerability issue for the affected CODESYS products:\n * CODESYS Runtime Toolkit 32 bit full version V2.4.7.56\n * CODESYS PLCWinNT version V2.4.7.56. This will also be part of the CODESYS Development System setup version V2.3.9.68."}],"source":{"defect":["VDE-2021-049"],"discovery":"EXTERNAL"}},"nvd":{"publishedDate":"2021-10-26 10:15:00","lastModifiedDate":"2022-04-12 18:05:00","problem_types":["CWE-755"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:P","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL","baseScore":5},"severity":"MEDIUM","exploitabilityScore":10,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:codesys:plcwinnt:*:*:*:*:*:*:*:*","versionEndExcluding":"2.4.7.56","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:x86:*","versionEndExcluding":"2.4.7.56","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"34593","Ordinal":"210058","Title":"CVE-2021-34593","CVE":"CVE-2021-34593","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"34593","Ordinal":"1","NoteData":"In CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56 unauthenticated crafted invalid requests may result in several denial-of-service conditions. Running PLC programs may be stopped, memory may be leaked, or further communication clients may be blocked from accessing the PLC.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"34593","Ordinal":"2","NoteData":"2021-10-26","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"34593","Ordinal":"3","NoteData":"2022-02-04","Type":"Other","Title":"Modified"}]}}}