{"api_version":"1","generated_at":"2026-04-23T07:56:08+00:00","cve":"CVE-2021-35535","urls":{"html":"https://cve.report/CVE-2021-35535","api":"https://cve.report/api/cve/CVE-2021-35535.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-35535","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-35535"},"summary":{"title":"CVE-2021-35535","description":"Insecure Boot Image vulnerability in Hitachi Energy Relion Relion 670/650/SAM600-IO series allows an attacker who manages to get access to the front network port and to cause a reboot sequences of the device may exploit the vulnerability, where there is a tiny time gap during the booting process where an older version of VxWorks is loaded prior to application firmware booting, could exploit the vulnerability in the older version of VxWorks and cause a denial-of-service on the product. This issue affects: Hitachi Energy Relion 670 Series 2.2.2 all revisions; 2.2.3 versions prior to 2.2.3.3. Hitachi Energy Relion 670/650 Series 2.2.0 all revisions; 2.2.4 all revisions. Hitachi Energy Relion 670/650/SAM600-IO 2.2.1 all revisions.","state":"PUBLIC","assigner":"cybersecurity@hitachienergy.com","published_at":"2021-11-18 16:15:00","updated_at":"2023-04-19 15:32:00"},"problem_types":["CWE-1188"],"metrics":[],"references":[{"url":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000061&LanguageCode=en&DocumentPartId=&Action=Launch","name":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000061&LanguageCode=en&DocumentPartId=&Action=Launch","refsource":"CONFIRM","tags":[],"title":"","mime":"application/pdf","httpstatus":"200","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-35535","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-35535","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[{"source":"LEGACY","value":"Hitachi Energy thanks the following for working with us to help protect customers: U.S. Department of Energy CyTRICS researcher Riley Barello Myers.","lang":""}],"nvd_cpes":[{"cve_year":"2021","cve_id":"35535","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hitachi","cpe5":"relion_650","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"35535","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hitachi","cpe5":"relion_650_firmware","cpe6":"2.2.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"35535","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hitachi","cpe5":"relion_650_firmware","cpe6":"2.2.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"35535","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hitachi","cpe5":"relion_650_firmware","cpe6":"2.2.4","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"35535","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hitachi","cpe5":"relion_670","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"35535","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hitachi","cpe5":"relion_670_firmware","cpe6":"2.2.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"35535","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hitachi","cpe5":"relion_670_firmware","cpe6":"2.2.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"35535","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hitachi","cpe5":"relion_670_firmware","cpe6":"2.2.2","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"35535","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hitachi","cpe5":"relion_670_firmware","cpe6":"2.2.4","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"35535","vulnerable":"1","versionEndIncluding":"2.2.3.3","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hitachi","cpe5":"relion_670_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"35535","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hitachi","cpe5":"relion_sam600-io","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"35535","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hitachi","cpe5":"relion_sam600-io_firmware","cpe6":"2.2.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"35535","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hitachienergy","cpe5":"relion_650","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"35535","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hitachienergy","cpe5":"relion_650_firmware","cpe6":"2.2.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"35535","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hitachienergy","cpe5":"relion_650_firmware","cpe6":"2.2.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"35535","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hitachienergy","cpe5":"relion_650_firmware","cpe6":"2.2.4","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"35535","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hitachienergy","cpe5":"relion_670","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"35535","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hitachienergy","cpe5":"relion_670_firmware","cpe6":"2.2.0","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"35535","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hitachienergy","cpe5":"relion_670_firmware","cpe6":"2.2.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"35535","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hitachienergy","cpe5":"relion_670_firmware","cpe6":"2.2.2","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"35535","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hitachienergy","cpe5":"relion_670_firmware","cpe6":"2.2.4","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"35535","vulnerable":"1","versionEndIncluding":"2.2.3.3","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hitachienergy","cpe5":"relion_670_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"35535","vulnerable":"-1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"h","cpe4":"hitachienergy","cpe5":"relion_sam600-io","cpe6":"-","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"35535","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"hitachienergy","cpe5":"relion_sam600-io_firmware","cpe6":"2.2.1","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2021-35535","qid":"590909","title":"Hitachi Energy Relion 670/650/SAM600-IO Vulnerability (ICSA-21-336-05)"}]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@hitachienergy.com","DATE_PUBLIC":"2021-11-04T11:00:00.000Z","ID":"CVE-2021-35535","STATE":"PUBLIC","TITLE":"Insufficient Security Control Vulnerability"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Relion 670 Series","version":{"version_data":[{"version_affected":"=","version_name":"2.2.2","version_value":"2.2.2 all revisions"},{"version_affected":"<","version_name":"2.2.3","version_value":"2.2.3.3"}]}},{"product_name":"Relion 670/650 Series","version":{"version_data":[{"version_affected":"=","version_name":"2.2.0","version_value":"2.2.0 all revisions"},{"version_affected":"=","version_name":"2.2.4","version_value":"2.2.4 all revisions"}]}},{"product_name":"Relion 670/650/SAM600-IO","version":{"version_data":[{"version_affected":"=","version_name":"2.2.1","version_value":"2.2.1 all revisions"}]}}]},"vendor_name":"Hitachi Energy"}]}},"credit":[{"lang":"eng","value":"Hitachi Energy thanks the following for working with us to help protect customers: U.S. Department of Energy CyTRICS researcher Riley Barello Myers."}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Insecure Boot Image vulnerability in Hitachi Energy Relion Relion 670/650/SAM600-IO series allows an attacker who manages to get access to the front network port and to cause a reboot sequences of the device may exploit the vulnerability, where there is a tiny time gap during the booting process where an older version of VxWorks is loaded prior to application firmware booting, could exploit the vulnerability in the older version of VxWorks and cause a denial-of-service on the product. This issue affects: Hitachi Energy Relion 670 Series 2.2.2 all revisions; 2.2.3 versions prior to 2.2.3.3. Hitachi Energy Relion 670/650 Series 2.2.0 all revisions; 2.2.4 all revisions. Hitachi Energy Relion 670/650/SAM600-IO 2.2.1 all revisions."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"HIGH","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":8.1,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-1188 Insecure Default Initialization of Resource"}]}]},"references":{"reference_data":[{"name":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000061&LanguageCode=en&DocumentPartId=&Action=Launch","refsource":"CONFIRM","url":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000061&LanguageCode=en&DocumentPartId=&Action=Launch"}]},"solution":[{"lang":"eng","value":"Refer to the cybersecurity advisories at https://www.hitachienergy.com/cybersecurity/alerts-and-notifications"}],"source":{"discovery":"EXTERNAL"}},"nvd":{"publishedDate":"2021-11-18 16:15:00","lastModifiedDate":"2023-04-19 15:32:00","problem_types":["CWE-1188"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","baseScore":8.1,"baseSeverity":"HIGH"},"exploitabilityScore":2.2,"impactScore":5.9},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL","baseScore":6.8},"severity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:hitachienergy:relion_670_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"2.2.3","versionEndIncluding":"2.2.3.3","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.0:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.1:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.2:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.4:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:hitachienergy:relion_670:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.0:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.1:*:*:*:*:*:*:*","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.4:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:hitachienergy:relion_650:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]},{"operator":"AND","children":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:hitachienergy:relion_sam600-io_firmware:2.2.1:*:*:*:*:*:*:*","cpe_name":[]}]},{"operator":"OR","children":[],"cpe_match":[{"vulnerable":false,"cpe23Uri":"cpe:2.3:h:hitachienergy:relion_sam600-io:-:*:*:*:*:*:*:*","cpe_name":[]}]}],"cpe_match":[]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"35535","Ordinal":"211038","Title":"CVE-2021-35535","CVE":"CVE-2021-35535","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"35535","Ordinal":"1","NoteData":"Insecure Boot Image vulnerability in Hitachi Energy Relion Relion 670/650/SAM600-IO series allows an attacker who manages to get access to the front network port and to cause a reboot sequences of the device may exploit the vulnerability, where there is a tiny time gap during the booting process where an older version of VxWorks is loaded prior to application firmware booting, could exploit the vulnerability in the older version of VxWorks and cause a denial-of-service on the product. This issue affects: Hitachi Energy Relion 670 Series 2.2.2 all revisions; 2.2.3 versions prior to 2.2.3.3. Hitachi Energy Relion 670/650 Series 2.2.0 all revisions; 2.2.4 all revisions. Hitachi Energy Relion 670/650/SAM600-IO 2.2.1 all revisions.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"35535","Ordinal":"2","NoteData":"2021-11-18","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"35535","Ordinal":"3","NoteData":"2021-11-18","Type":"Other","Title":"Modified"}]}}}