{"api_version":"1","generated_at":"2026-07-24T03:27:30+00:00","cve":"CVE-2021-36299","urls":{"html":"https://cve.report/CVE-2021-36299","api":"https://cve.report/api/cve/CVE-2021-36299.json","docs":"https://cve.report/api","cve_org":"https://www.cve.org/CVERecord?id=CVE-2021-36299","nvd":"https://nvd.nist.gov/vuln/detail/CVE-2021-36299"},"summary":{"title":"CVE-2021-36299","description":"Dell iDRAC9 versions 4.40.00.00 and later, but prior to 4.40.29.00 and 5.00.00.00 contain an SQL injection vulnerability. A remote authenticated malicious user with low privileges may potentially exploit this vulnerability to cause information disclosure or denial of service by supplying specially crafted input data to the affected application.","state":"PUBLIC","assigner":"secure@dell.com","published_at":"2021-11-23 20:15:00","updated_at":"2021-11-27 03:49:00"},"problem_types":["CWE-89"],"metrics":[],"references":[{"url":"https://support.emc.com/kb/000191229","name":"N/A","refsource":"CONFIRM","tags":[],"title":"Access Denied","mime":"text/html","httpstatus":"403","archivestatus":"404"},{"url":"https://www.cve.org/CVERecord?id=CVE-2021-36299","name":"CVE Program record","refsource":"CVE.ORG","tags":["canonical"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2021-36299","name":"NVD vulnerability detail","refsource":"NVD","tags":["canonical","analysis"]}],"affected":[],"timeline":[],"solutions":[],"workarounds":[],"exploits":[],"credits":[],"nvd_cpes":[{"cve_year":"2021","cve_id":"36299","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"dell","cpe5":"emc_idrac9_firmware","cpe6":"*","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"},{"cve_year":"2021","cve_id":"36299","vulnerable":"1","versionEndIncluding":"","cpe1":"cpe","cpe2":"2.3","cpe3":"o","cpe4":"dell","cpe5":"emc_idrac9_firmware","cpe6":"5.00.00.00","cpe7":"*","cpe8":"*","cpe9":"*","cpe10":"*","cpe11":"*","cpe12":"*","cpe13":"*"}],"vendor_comments":[],"enrichments":{"kev":null,"epss":null,"legacy_qids":[{"cve":"CVE-2021-36299","qid":"730379","title":"Dell Precision Rack Security Update for Multiple iDRAC Vulnerabilities (DSA-2021-177) -iDRAC 8,9"}]},"source_records":{"cve_program":{"CVE_data_meta":{"ASSIGNER":"secure@dell.com","DATE_PUBLIC":"2021-09-09","ID":"CVE-2021-36299","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Integrated Dell Remote Access Controller (iDRAC)","version":{"version_data":[{"version_affected":"<","version_value":"5.00.00.00"}]}}]},"vendor_name":"Dell"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Dell iDRAC9 versions 4.40.00.00 and later, but prior to 4.40.29.00 and 5.00.00.00 contain an SQL injection vulnerability. A remote authenticated malicious user with low privileges may potentially exploit this vulnerability to cause information disclosure or denial of service by supplying specially crafted input data to the affected application."}]},"impact":{"cvss":{"baseScore":7.1,"baseSeverity":"High","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')"}]}]},"references":{"reference_data":[{"refsource":"MISC","url":"https://support.emc.com/kb/000191229","name":"https://support.emc.com/kb/000191229"}]}},"nvd":{"publishedDate":"2021-11-23 20:15:00","lastModifiedDate":"2021-11-27 03:49:00","problem_types":["CWE-89"],"metrics":{"baseMetricV3":{"cvssV3":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"HIGH","baseScore":8.1,"baseSeverity":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.2},"baseMetricV2":{"cvssV2":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:N/A:P","accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"PARTIAL","baseScore":5.5},"severity":"MEDIUM","exploitabilityScore":8,"impactScore":4.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}},"configurations":{"CVE_data_version":"4.0","nodes":[{"operator":"OR","children":[],"cpe_match":[{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:dell:emc_idrac9_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"4.40.00.00","versionEndExcluding":"4.40.29.00","cpe_name":[]},{"vulnerable":true,"cpe23Uri":"cpe:2.3:o:dell:emc_idrac9_firmware:5.00.00.00:*:*:*:*:*:*:*","cpe_name":[]}]}]}},"legacy_mitre":{"record":{"CveYear":"2021","CveId":"36299","Ordinal":"211843","Title":"CVE-2021-36299","CVE":"CVE-2021-36299","Year":"2021"},"notes":[{"CveYear":"2021","CveId":"36299","Ordinal":"1","NoteData":"Dell iDRAC9 versions 4.40.00.00 and later, but prior to 4.40.29.00 and 5.00.00.00 contain an SQL injection vulnerability. A remote authenticated malicious user with low privileges may potentially exploit this vulnerability to cause information disclosure or denial of service by supplying specially crafted input data to the affected application.","Type":"Description","Title":null},{"CveYear":"2021","CveId":"36299","Ordinal":"2","NoteData":"2021-11-23","Type":"Other","Title":"Published"},{"CveYear":"2021","CveId":"36299","Ordinal":"3","NoteData":"2021-11-23","Type":"Other","Title":"Modified"}]}}}